Alarm · SINAMICS G120, G130, G150, S120, S150

A01953CU SYNC: Synchronization not completed

What it means

A01953 is an alarm that appears when the drive system is switched on: the synchronization between the drive's internal clock cycles was started but was not completed within the selected time tolerance. The manuals title the message CU SYNC: Synchronization not completed. The message value is the alarm value held in r2124, interpreted as a decimal number; the manual assigns it to internal Siemens troubleshooting only, so it names no action for the technician.

Why it appears

  • After the drive system is switched on, the synchronization between the basic clock cycle, the DRIVE-CLiQ clock cycle and the application clock cycle was started but was not completed within the selected time tolerance.
  • The manuals differ only in which clocks they name: the entries for the G130, G150, S120 and S150 include the DRIVE-CLiQ clock cycle, while the G120 entry names the basic clock cycle and the application clock cycle.
  • The manual names one situation in which the alarm can show up again: after the drive sampling times were changed, on systems where a Terminal Module 31 (TM31) is being used.

What to check

  1. Carry out a POWER ON (switch-off/switch-on) for all components.
  2. If the alarm occurs again after the drive sampling times were changed and a Terminal Module 31 (TM31) is being used, follow the manual's wording: the sampling times (p0115, p4099) should be set as integer multiples to the drive clock cycles (p0115). This second step is printed for the G130, G150, S120 and S150 entries; the G120 manual gives only the POWER ON.

Reading the message value

  • The manual prints the message value as the placeholder %1 and ties it to the alarm value in r2124.
  • r2124 is interpreted as a decimal number.
  • Per the manual, this alarm value is only for internal Siemens troubleshooting — no decoding is given that a technician could act on.

Parameters the manual names

  • r2124 — alarm value of this message; interpret it as a decimal number. The manual assigns it to internal Siemens troubleshooting only, so there is nothing to set here.
  • p0115 — sampling time for supplementary functions; in the TM31 case it is one of the sampling times that must be set as integer multiples of the drive clock cycle (p0115).
  • p4099 — TM31 inputs/outputs sampling time; like p0115, set it as an integer multiple of the drive clock cycle (p0115) when the alarm follows a change of the drive sampling times and a TM31 is used.

Acknowledging and restarting

No acknowledgement is required for this alarm. The manual's remedy is the POWER ON (switch-off/switch-on) of all components; if the alarm comes back after the restart, work through the checks above — with a Terminal Module 31 (TM31) connected, in particular the integer-multiple setting of the sampling times (p0115, p4099).

What differs between the drive families

Straight from the manuals' own fields — A01953 is not described identically everywhere.

Drive familyReactionAcknowledgeMessage classComponentManual
G130, G150NONENONEInternal (DRIVE-CLiQ) communication error (12)NoneSINAMICS G130, G150 List Manual · p. 1496
S120, S150NONENONEInternal (DRIVE-CLiQ) communication error (12)NoneSINAMICS S120, S150 List Manual · p. 2720
G120NONENONEInternal (DRIVE-CLiQ) communication error (12)SINAMICS G120 · p. 862

The drives this code lives on

A01953 is described for G120, G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does SINAMICS alarm A01953 mean?

After the drive system is switched on, the synchronization between the clock cycles — basic, application and, on the systems that include it, DRIVE-CLiQ — was started but was not completed within the selected time tolerance.

How do I clear A01953?

Carry out a POWER ON (switch-off/switch-on) for all components. No acknowledgement is required.

Why does A01953 keep coming back after every switch-on?

The manual gives one follow-up for that case: if the alarm occurs after the drive sampling times were changed and a Terminal Module 31 (TM31) is being used, set the sampling times (p0115, p4099) as integer multiples of the drive clock cycle (p0115).

What is the alarm value of A01953 in r2124?

It is interpreted as a decimal number and, per the manual, is only for internal Siemens troubleshooting — it names no action for the user.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the A01xxx group · SINAMICS manuals · Siemens manuals