TR41
On order
WIKA · Temperature measurement · Family TR

Cable resistance thermometer

Cable resistance thermometer with tubular design for direct process installation, available with various process connections and explosion protection options.
Range
-60…400 °C
Output
4-20mA · HART
Protection
IP65
CERoHSINMETROCCCNEPSIKCsPESOATEXIECExEMCII 1G Ex ia IIC T1 ... T6 GaII 2G Ex ia IIC T1 ... T6 GbII 2G Ex eb IIC T1 ... T6 GbII 3G Ex ec IIC T1 ... T6 Gc XII 3D Ex tc IIIC TX °C Dc XII 2D Ex tb IIIC TX °C DbII 3G Ex nA IIC T1 ... T6 Gc XEx ia IIC T1 ~ T6 GaEx ia IIC T1 ~ T6 GbEx ia IIC T1 ~ T6 Ga/GbEx ic IIC T1 ~ T6 GcEx iaD 20 T65/T95/T125 °CEx iaD 21 T65/T95/T125 °CEx iaD 20/21 T65/T95/T125 °CEx eb IIC T1 ~ T6 GbEx ec IIC T1 ~ T6 GcEx tD A21/A22 IP66 T135 °CEx nA IIC T4 ... T6Ex ib IIC T4 ... T6KCs: Ex ib IIC T4 ...T6II 2D Ex tb IIC TX °C DbII 3D Ex tc IIC TX °C Dc XEx ia IIC T1 ... T6 GaEx ia IIC T1 ... T6 Ga/GbEx ia IIC T1 ... T6 GbEx ia IIC T125 ... T65 °C DaEx ia IIC T125 ... T65 °C Da/DbEx ia IIC T125 ... T65 °C DbEx eb IIC T1...T6 GbEx ec IIC T1...T6 GcEx tb IIC TX °C DbEx tc IIC TX °C DcEx nA IIC T1...T6 GcEx nAIICT1~T6GcExiaIICT1~T6GaExiaIICT1~T6GbExiaIICT1~T6Ga/GbExicIICT1~T6GcExiaD20T65/T95/T125℃ExiaD21T65/T95/T125℃ExiaD20/21T65/T95/T125℃ExebIICT1~T6GbExnAIICT1~T6GcExtD A21/A22IP66T135℃ExiaIICT4...T6ExibIICT4...T6ExiaIICT1...T6GaExiaIICT1...T6Ga/GbExicIICT1...T6Gc
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

Cable resistance thermometers are particularly suited to those applications in which the metallic probe tip is mounted directly into bored holes (e.g. in machine components) or directly into the process, and for any application with no chemically aggressive media or abrasion.

A large number of different explosion protection approvals are availabe for the TR41.

for further approvals see page 2

Cable resistance thermometer, model TR41

For mounting into a thermowell, a spring-loaded compression fitting should be provided, since only this can press the measuring tip into the bottom of the thermowell. Otherwise a potentially critical force could be exerted on the measuring tip.

In the standard version the cable probes are manufactured without process connections. Fastening elements such as threaded connections, compression fittings, etc. are possible as options.

Special features

  • Sensor ranges from -50 ... +250 °C [-58 ... +482 °F]
  • For insertion or screw-in with optional process connection
  • Cable from PTFE, PFA, silicone and other cable sheath materials
  • Versions with/without connector or connection housing (option)
  • Explosion-protected versions are available for many approval types (see data sheet page 2)
Configurator · Step by step

Build a TR41 for your task

The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.

Step 1 of 4
Configuration structure· click a highlighted segment to jump to that parameter
Your configuration
  • Electrical approvalWithout
  • Ignition protection typeWithout
  • ZoneWithout
  • DesignWith lead wires
  • Sensor1xPt100, 3-wire
  • Accuracy class of the sensorClass B, IEC 60751
  • Temperature range of selected class-50...+250°C
  • Probe designStraight
  • Unit of measureMetric (mm)
  • Lead wire insulationPTFE/PFA jacket, application range -60...+250 °C
  • Cable length [W]1.000
  • Cable endingStripped leads
  • Cord gripWithout
  • Process connectionWithout
  • Thread sizeWithout
  • Material process connectionWithout
  • Probe diameter—
  • Probe material—
  • Transition—
  • A-dimension [A]—
  • Mechanical requirementsStandard probe tip (max. 3 g amplitude / 6 g peak to peak)
  • CertificatesWithout