AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
TR33 1
TR33
In stock at WIKA
WIKA · Temperature measurement · Family TR33

Miniature resistance thermometer

Miniature resistance thermometer with threaded connection, available with direct sensor output (Pt100, Pt1000) or integrated 4-20mA transmitter, high vibration resistance and fast response time.
Range
-50…250 °C
Output
4-20mA · HART
Accuracy
±0.25 K
Protection
IP67
CERoHSREACH
Price
From €90
Confirm at order time
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

Resistance thermometers of these series are used as universal thermometers for the measurement of liquid and gaseous media in the range -50 ... +250 °C [-58 ... +482 °F].

They can be used for pressures up to 140 bar [2,030 psi] with 3 mm [0.12 in] protection tube diameters and up to 270 bar [3,916 psi] with 6 mm [0.24 in] protection tube diameters, depending on the instrument version. All electrical components are protected against humidity (IP67 or IP69K) and designed to withstand vibration (20 g, depending on instrument version).

The resistance thermometer is available with direct sensor output or integrated transmitter, which can be configured individually via the WIKAsoft-TT PC configuration software. Measuring range, dampening, error signalling per NAMUR NE 043 and tag no. can be adjusted.

for further approvals see page 6

Fig. left: Resistance thermometer, model TR33 Fig. right: M12 x 1 adapter to DIN EN 175301-803 angular connector

Insertion length, process connection, sensor and connection method can each be selected for the respective application within the ordering information. The model TR33 resistance thermometer consists of a protection tube with a fixed process connection and is screwed directly into the process. The electrical connection is made via an M12 x 1 circular connector. An adapter for electrical connection with angular connector per DIN EN 175301-803 is optionally available (patent, industrial property right: 001370985).

Special features

  • Very compact design, high vibration resistance and fast response time
  • With direct sensor output (Pt100, Pt1000 in 2-, 3- or 4-wire connection) or integrated transmitter with 4 ... 20 mA output signal
  • Integrated transmitter is individually parameterisable with free-of-charge WIKAsoft-TT PC configuration software
  • Sensor element with accuracy class A per IEC 60751
Identification
ModelTR33
SubcategoryResistance thermometer
Measuring range
Temperature ranges−50…+250 °C · −30…+250 °C · −20…+125 °C
Accuracy
Accuracy class±0.25 K
Process conditions
Process connection
G¼BG⅜BG½B¼NPT½NPTM12 x 1.5M20 x 1.57/16-20 UNF-2A
Process temperature−50…+250 °C
Electrical characteristics
Output signal4-20mA · HART
Power supplyDC 10 ... 30V
Electrical connectionM12 x 1 circular connector (4-pin)
Materials
Probe materialStainless steel 1.4571
Operating environment
Ambient temperature−40…+85 °C
IP ratingIP67
Certifications and approvals
Certifications
CERoHSREACH
Additional details
Sensor typePt100, Pt1000
Sensor classA, B
Probe diameter3 mm
ThermowellNo
Datasheet languagesEN, DE
Tables from datasheet
Measuring element
Type of measuring element
Version 4 ... 20 mA(modelTR33-Z-TT)Pt1000 (measuring current < 0.3 mA;self-heating can be ignored)
Version Pt100 (model TR33-Z-Px) / Pt1000 (model TR33-Z-Sx)■ Pt100 (measuring current: 0.1 ... 1.0 mA) ■ Pt1000 (measuring current: 0.1 ... 0.3 mA)
→ For detailed specifications for Pt sensors, see Technical information IN 00.17 at www.wika.com.
Connection method
Version 4 ... 20 mA(modelTR33-Z-TT)2-wire
Version Pt100 (model TR33-Z-Px) / Pt1000 (model TR33-Z-Sx)2-wireThe lead resistance is recorded as an error in the measurement
3-wireWith a cable length of 30 mor longer, measuring deviations can occur
4-wireThe lead resistance can be ignored
Tolerance value of the measuring element 1) per IEC 60751
Version 4 ... 20 mA(modelTR33-Z-TT)Class A
Version Pt100 (model TR33-Z-Px) / Pt1000 (model TR33-Z-Sx)■ Class A ■ Class B at2-wire
Accuracy specifications (4 ... 20 mA version)
Tolerance value of the measuring element 1) per IEC 60751Class A
Measuring deviation of the transmitter per IEC 62828±0.25 K
Total measuring deviation per IEC 62828Measuring deviation of the measuring element + transmitter
Influence of the ambient temperature0.1 %of the set measuring span / 10 KT a
Influence of supply voltage±0.025 %/V(depending on the supply voltage U B )
Influence of the load±0.05 %/ 100Ω
LinearisationLinear to temperature per IEC 60751
Output error±0.1% 2)
Reference conditions
Ambient temperatureT a ref23 °C
Supply voltage U B refDC 12V
Measuring range
Temperature range
Version 4 ... 20 mA(modelTR33-Z-TT)Without neck tube -30 ...+150 °C [-22 ...+302 °F] With neck tube -30 ...+250 °C [-22 ...+482 °F] 1) Version with FKM O-ring: -20 ...+125 °C [-4 ...+257 °F]
Version Pt100 (model TR33-Z-Px) / Pt1000 (model TR33-Z-Sx)Class AWithout neck tube -30 ...+150 °C [-22 ...+302 °F] With neck tube -30 ...+250 °C [-22 ...+482 °F] Version with FKM O-ring: -20 ...+125 °C [-4 ...+257 °F]
Class BWithout neck tube -50 ...+150 °C [-58 ...+302 °F] With neck tube -50 ...+250 °C [-58 ...+482 °F]
Unit (4 ... 20 mA version)Configurable °C, °F, K
Temperature at the connector (Pt100, Pt1000 version)Max. 85 °C [185 °F]
Measuring span (4 ... 20 mA version)Minimum 20 K, maximum 300 K
Process connection
Type of process connection■ G¼B ■ G⅜B ■ G½B ■ ¼NPT ■ ½NPT ■ M12 x 1.5 ■ M20 x 1.5 ■ 7/16-20 UNF-2A
Protection tube
Protection tube diameter■ 3 mm[0.12 in] ■ 6 mm[0.24 in]
Insertion length U 1■ 50 mm[1.97 in] ■ 75 mm[2.95 in] 1) ■ 100 mm[3.94 in] 1) ■ 120 mm[4.72 in] 1) ■ 150 mm[5.91 in] 1) ■ 200 mm[7.87 in] 1) ■ 250 mm[9.84 in] 1) ■ 300 mm[11.81 in] 1) ■ 350 mm[13.78 in] 1) ■ 400 mm[15.75 in] 1) Other insertion lengths on
request
Material (wetted)Stainless steel 1.4571
View all (14)
Output signal (4 ... 20 mA version)
Analogue output4 ... 20 mA, 2-wire
Load R AR A ≤ (U B - 10 V) / 23 mAwith R A in Ωand U B inV The permissible load depends on the loop supply voltage. For communication with the instrument with programming unit PU-548, a max. load of 350 Ωis admissible.
Load diagramLoad R A inΩ Voltage U B inV 0 10 24 30 36 1083 833 583
Factory configuration
Measuring rangeMeasuring range 0 ... 150 °C [32 ... 302 °F] Other measuring ranges are adjustable
Current signals for error signallingConfigurable in accordance with NAMUR NE 043 downscale ≤ 3.6mA upscale ≥ 21.0mA
Current value for sensor short-circuitNot configurable in accordance with NAMUR NE 043 downscale ≤ 3.6mA
Communication
Info dataTag no., description and user message can be stored in transmitter
Configuration and calibration dataPermanently stored
Configuration softwareWIKAsoft-TT → Configuration software (multilingual) as a download from www.wika.com
Voltage supply
Supply voltage U BDC 10 ...30V
Supply voltage inputProtected against reverse polarity
Permissible residual ripple of supply voltage10 %generated by U B < 3 %ripple of the output current
Time response
Switch-on delay, electricalMax. 4 s (time before the first measured value)
Warm-up timeAfter approx. 4 minutes, the instrument will function to the specifications (accuracy) given in the data sheet.
Electrical connection
Connection typeM12 x 1 circular connector (4-pin)
MaterialStainless steel 1.4571
PinSignalDescription
1L+10 ...30V
2VQnot connected
3L-0V
4Cnot connected
Operating conditions
Ambient temperature range
Version 4 ... 20 mA(modelTR33-Z-TT)-40 ...+85 °C [-40 ...+185 °F] Version with FKM O-ring: -20 °C [-4 °F]
Version Pt100 (model TR33-Z-Px) / Pt1000 (model TR33-Z-Sx)-50 ...+85 °C [-58 ...+185 °F] Version with FKM O-ring: -20 °C [-4 °F]
Storage temperature range-40 ...+85 °C [-40 ...+185 °F] Version with FKM O-ring: -20 °C [-4 °F]
Climate class per IEC 60654-1
Version 4 ... 20 mA(modelTR33-Z-TT)Cx (-40 ...+85 °C [-40 ...+185 °F], 5 ... 95 %r.h.) Version with FKM O-ring: -20 °C [-4 °F]
Version Pt100 (model TR33-Z-Px) / Pt1000 (model TR33-Z-Sx)Cx (-50 ...+85 °C [-58 ...+185 °F], 5 ... 95 %r.h.) Version with FKM O-ring: -20 °C [-4 °F]
Maximum permissible humidity, condensation100 %r.h., condensation allowed
Maximum operating pressure 1) 2)
For protection tube diameter 3 mm[0.12 in]140 bar [2,030 psi]
For protection tube diameter 6 mm[0.24 in]270 bar [3,916 psi]
Salt fogIEC 60068-2-11
Vibration resistance per IEC 6075110 ... 2,000 Hz, 20 g 1)
Shock resistance per IEC 60068-2-2750 g, 6 ms, 3 axes, 3 directions, three times per direction
Maximum permissible autoclaving conditionsMax. 134 °C, 3 bar abs., 100 %r.h., duration 20 min., max. 50 cycles
Autoclavable with mounted protective cap at coupler connector
Conditions for outdoor use (only applies to UL approval)■ The instrument is suitable for applications with pollution degree 3. ■ The power supply must be suitable for operation above 2,000m should the temperature transmitter be used at this altitude. ■ The instrument shall be installed in locations sheltered from the weather. ■ The instrument shall be installed sun/UV irradiation protected.
Operating conditions
Ingress protection (IP code)
Case with connected connector 3)■ IP67 per IEC/EN 60529 ■ IP69 per IEC/EN 60529 ■ IP69K per ISO 20653
Coupler connector, not connectedIP67 per IEC/EN 60529
Weightapprox. 0.2 ... 0.7 kg [0.44 ... 1.54 lbs] - depending on version
LogoDescriptionCountry
EU declaration of conformityEuropean Union
CSA Safety (e.g. electr. safety, overpressure, ...)USA and Canada
UL Safety (e.g. electr. safety, overpressure, ...)USA and Canada
LogoDescriptionCountry
EAC EMCdirective 1)Eurasian Economic Community
GOST Metrology, measurement technologyRussia
KazInMetr Metrology, measurement technologyKazakhstan
-MTSCHS Permission for commissioningKazakhstan
BelGIM Metrology, measurement technologyBelarus
UkrSEPRO Metrology, measurement technologyUkraine
Uzstandard Metrology, measurement technologyUzbekistan
Certification typeMeasurement accuracyMaterial certificate
2.2 test reportxx
3.1 inspection certificatexx
DKD/DAkkS calibration certificatex-
ModelDescriptionOrder no.
Programming unit Model PU-548■ Easy to use ■ LED status display ■ Compact design ■ No further voltage supply needed, neither for the programming unit nor for the transmitter14231581
Adapter cable M12 to PU-548Adapter cable for the connection of a modelTR33 resistance thermometer to the model PU-548 programming unit14003193
M12 x 1 transmitter adapter to DIN EN 175301-803 angular connector (yellow female connector element)Adapter for the connection of a resistance thermometer with a DIN EN 175301-803 angular connector form A with a 4 ... 20 mAoutput signal → see data sheet AC 80.17 Case: PA Ambient temperature: -40 ...+115 °C [-40 ...+239 °F] Union nut: Zinc die-cast Contacts: Copper-zinc alloy, tinned Dielectric strength: 500V Ingress protection: IP65 4 ...20mA M12 x 1 connector Angular connector14069503
M12 x 1 Pt adapter to DIN EN 175301-803 angular connector (black female connector element)Adapter for the connection of the resistance thermometer with a DIN EN 175301-803 form A angular connector with direct resistance output signal → see data sheet AC 80.17 Case: PA Ambient temperature: -40 ...+115 °C [-40 ...+239 °F] Union nut: Zinc die-cast Contacts: Copper-zinc alloy, tinned Dielectric strength: 500V Ingress protection: IP65 mA 4 ...20mA M12 x 1 connector Angular connector14061115
Angular connectorPer DIN EN 175301-803 form A11427567
Sealing for angular connectorFor use with angular connector DIN EN 175301-803-A EPDM, brown11437902
ModelDescriptionOrder no.
-M12 connection cableCable socket straight, 4-pin, ingress protection IP67 Temperature range -20 ...+80 °C [-4 ...+176 °F]Cable length2m [6.56 ft]14086880
Cable length5m [16.40 ft]14086883
Cable socket straight, 4-pin, ingress protection IP69K, hygienic design Union nut from stainless steel Temperature range -40 ...+80 °C [-40 ...+176 °F]Cable length3m [9.84 ft]14137167
Cable length5m [16.40 ft]14137168
Angled socket, 4-pin, ingress protection IP67 Temperature range -20 ...+80 °C [-4 ...+176 °F]Cable length2m [6.56 ft]14086889
Cable length5m [16.40 ft]14086891
Angled socket, 4-pin, ingress protection IP69K, hygienic design Union nut from stainless steel Temperature range -40 ...+80 °C [-40 ...+176 °F]Cable length3m [9.84 ft]14137169
Cable length5m [16.40 ft]14137170
-M12 connectorFemale angled, 4-pin, ingress protection IP67 Screw connection for conductor cross-section 0.25 …0.75 mm² [24 …18 AWG] Cable gland Pg7, outside diameter of cable 4 …6mm[0.16 ... 0.24 in]14136815