AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
TR25 1
TR25
On order
WIKA · Temperature measurement · Family TR

In-line resistance thermometer

In-line resistance thermometer for sanitary applications with high hygienic requirements, suitable for piggable systems, SIP and CIP cleaning.
Range
-50…150 °C
Output
HART® protocol
Accuracy
±1 Kelvin + accuracy of the relevant transmitter at 100 °C
Protection
IP65
CERoHS3-AEHEDGULEACREACHEx ia IIC T1 ... T6 GaEx ia IIC T1 ... T6 GbII 3D Ex tc IIIC TX °C Dc X0Ex ia IIC T3/T4/5/T61Ex ib IIC T3/T4/5/T6II 1G Ex ia IIC T1 ... T6 GaII 2G Ex ia IIC T1 ... T6 GbII 2G Ex eb IIC T1 ... T6 GbII 3G Ex ec IIC T1 ... T6 Gc XII 2D Ex tb IIIC TX °C DbII 3G Ex nA IIC T1 ... T6 Gc XEx ia IIIC T125 ... T65 °C DaEx ia IIIC T125 ... T65 °C Da/DbEx ia IIIC T125 ... T65 °C Db2Ex nA IIC T6 ... T1 Gc XEx ia IIIC T65°C DaEx ia IIIC T65°C DbEx ia IIC T1~T6 GaEx ia IIC T1~T6 GbEx ic IIC T1~T6 GcEx iaD 20 T65/T95/T125Ex iaD 21 T65/T95/T125Ex ia IIC T4 ... T6Ex ib IIC T4 ... T6ATEXIECExII 1G Ex ia IIC T1 ...T6 GaII 2G Ex ia IIC T1 ...T6 GbII 1D Ex ia IIC T125 ...T65℃DaII 2D Ex ia IIC T125 ...T65℃DbII 2G Ex eb IIC T1 ...T6 GbII 3G Ex ec IIC T1 ...T6 Gc XII 2D Ex tb IIC TX℃DbII 3D Ex tc IIC TX℃DcXII 3G Ex nA IIC T1 ...T6 Gc XEx ia IIC T1 ...T6 GaEx ia IIC T1 ...T6 GbEx ia IIC T125 ...T65℃DaEx ia IIC T125 ...T65℃Da/DbEx ia IIC T125 ...T65℃Db2Ex nA IIC T6 ...T1 GcExia IIC T1 ~~T6 GaExia IIC T1~~ T6 GbExic IIC T1~T6 GcExiaD20T65/T95/T125ExiaD21T65/T95/T125Exia IIC T4...T6Exib IIC T4...T6Exia IIC T1...T6GaExia IIC T1...T6Gb
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

Resistance thermometer for temperature measurement in pipelines with extremely high hygienic requirements. This thermometer is used in applications where a thermowell/ protection tube immersed into the process medium is not possible or not desired, particularly for piggable pipelines, highly viscous media and flow conditions with high shear forces. A wide variety of process connections enables problem-free fitting into many different processes.

For further approvals, see page 8

In-line resistance thermometer, model TR25 Options: sealing combination at neck tube, cable gland in Hygienic Design

3- or 4-wire platinum measuring resistors in accuracy classes A and B per DIN EN 60751 serve as sensors.

Analogue or digital transmitters built into the connection head are capable of making various output signals available, for example 4 ... 20 mA, HART ® protocol, FOUNDATION™ Fieldbus or PROFIBUS ® PA.

Special features

  • Hygienic design (dead space free transitions)
  • Residue-free and quick cleaning of the measuring point (piggable, suitable for SIP and CIP)
  • Materials and surface finish qualities in accordance with pharmaceutical industry directives and standards
  • High measuring accuracy with short response times
  • Also as explosion-protected versions
Identification
ModelTR25
Product familyTR
SubcategoryIn-line resistance thermometer
Measuring range
Temperature ranges−50…+150 °C · −30…+150 °C
Accuracy
Accuracy class±1 Kelvin + accuracy of the relevant transmitter at 100 °C
Process conditions
Process connection
DIN 11864-1 form ANEUMO BioConnect®DIN 11866 row ADIN 11866 row BDIN 32676DIN 11851DIN 11866 row CTRI-CLAMP®BS4825 part 3ASME BPEDIN 11866 row A, B, CDIN 32676 clampDIN 11851 threaded
Process temperature−50…+150 °C
Electrical characteristics
Output signalHART® protocol · FOUNDATION™ Fieldbus · PROFIBUS® PA · 4 ... 20 mA · HART
Electrical connectionM20 x 1.5, M16 x 1.5, M12 x 1 coupler connector (4-pin)
Materials
Probe materialStainless steel 1.4435 (316L), Stainless steel
Operating environment
Ambient temperature−40…+85 °C
IP ratingIP65
Certifications and approvals
Certifications
CERoHS3-AEHEDGULEACREACH
Explosion protection
Ex ia IIC T1 ... T6 GaEx ia IIC T1 ... T6 GbII 3D Ex tc IIIC TX °C Dc X0Ex ia IIC T3/T4/5/T61Ex ib IIC T3/T4/5/T6II 1G Ex ia IIC T1 ... T6 GaII 2G Ex ia IIC T1 ... T6 GbII 1D Ex ia IIIC T125 ... T65 °C DaII 1/2D Ex ia IIIC T125 ... T65 °C Da/DbII 2D Ex ia IIIC T125 ... T65 °C DbII 2G Ex eb IIC T1 ... T6 GbII 3G Ex ec IIC T1 ... T6 Gc XII 2D Ex tb IIIC TX °C DbII 3G Ex nA IIC T1 ... T6 Gc XEx ia IIIC T125 ... T65 °C DaEx ia IIIC T125 ... T65 °C Da/DbEx ia IIIC T125 ... T65 °C Db2Ex nA IIC T6 ... T1 Gc XEx ia IIIC T65°C DaEx ia IIIC T65°C DbEx ia IIC T1~T6 GaEx ia IIC T1~T6 GbEx ic IIC T1~T6 GcEx iaD 20 T65/T95/T125Ex iaD 21 T65/T95/T125Ex ia IIC T4 ... T6Ex ib IIC T4 ... T6ATEXIECExII 1D Ex ia IIC T125 ...T65℃DaII 1/2D Ex ia IIC T125 ...T65℃Da/DbII 2D Ex ia IIC T125 ...T65℃DbII 2D Ex tb IIC TX℃DbII 3D Ex tc IIC TX℃DcXEx ia IIC T125 ...T65℃DaEx ia IIC T125 ...T65℃Da/DbEx ia IIC T125 ...T65℃Db2Ex nA IIC T6 ...T1 GcExia IIC T1 ~~T6 GaExia IIC T1~~ T6 Gb
Additional details
Sensor typePt100
Sensor classA
Probe length71 mm
Probe diameter12 mm
ThermowellNo
Datasheet languagesEN, DE
Tables from datasheet
Measuring element
Type of measuring element 1)Pt100 (thin-film)
→ For detailed specifications for Pt sensors, see technical information IN 00.17 at www.wika.com.
Measuring current
Transmitter versionModel T15< 0.2mA
Model T32< 0.3mA
Pt100 version (without transmitter)0.1 ...1.0mA
Connection method
Transmitter version■ 1 x 3-wire ■ 1 x 4-wire
Pt100 version (without transmitter)■ 1 x 3-wire ■ 1 x 4-wire
Tolerance value of the measuring element 2) per IEC 60751■ Class A ■ Class B
Connection head
ModelMaterialCable inlet thread sizeIngress protection (max.) 1) IEC/EN 60529CapSurface
BSAluminium■ M20 x 1.5 ■ M12 x 1 coupler connec- tor (4-pin)IP65 3)Flat cover with 2 screwsBlue, painted (RAL 5022)
BSZ, BSZ-K BSZBSZ-H, BSZ-HK AluminiumBSS BSS-H ■ M20 x 1.5 ■ M12 x 1 coupler connec- tor (4-pin)BVS IP65 3)BVS (NuG) Spherical hinged cover with cylinder head screw1/4000 Blue, painted (RAL 5022)
BSZ-H, BSZ-HK BSZ-HBSS AluminiumBVS BSS-H ■ M20 x 1.5 ■ M12 x 1 coupler connec- tor (4-pin)BVS (NuG) IP65 3)1/4000 Raised hinged cover with cylinder head screw7/8000 5/6000 Blue, painted (RAL 5022)
BSS BSZ-HKBSS-H PAV antistat- ic PA12BVS BVS (NuG) ■ M20 x 1.5 ■ M12 x 1 coupler connec- tor (4-pin)1/4000 IP657/8000 5/6000 Raised hinged cover with cylinder head screw7/8000 DIH50 Black
BSZ-H / DIH10 2)Aluminium■ M20 x 1.5 ■ M12 x 1 coupler connec- tor (4-pin)IP65Raised hinged cover with cylinder head screwBlue, painted (RAL 5022)
BSSAluminium■ M20 x 1.5 ■ M12 x 1 coupler connec- tor (4-pin)IP65Spherical hinged cover with clamping leverBlue, painted (RAL 5022)
BSS-H BSS-HBVS AluminiumBVS (NuG) 1/4000 ■ M20 x 1.5 ■ M12 x 1 coupler connec- tor (4-pin)5/6000 IP657/8000 DIH50 7/8000 Raised hinged cover with clamping leverandere Anschlussgehäuse Blue, painted (RAL 5022)
BVS BVSBVS (NuG) Stain- less steel (1.4308)5/6000 1/4000 ■ M20 x 1.5 ■ M12 x 1 coupler connec- tor (4-pin)7/8000 7/8000 IP65DIH50 andere Anschlussgehäuse Screw-on lid, Hygienic DesignKN4-P Natural finish, electropol- ished
BVS (NuG) BVC1/4000 Stain- less steel (1.4571)7/8000 5/6000 ■ M16 x 1.5 ■ M12 x 1 coupler connec- tor (4-pin)7/8000 DIH50 andere IP68 4)KN4-P Anschlussgehäuse Flat screw-on lidBVC Metal bright finished
TransmitterModel T15Model T32
Transmitter data sheetTE 15.01TE 32.04
Figure
Analogue output4 ...20mA■ 4 ...20mA ■ HART ® protocol
Possible assembly combinations
BVC○○
BVS○○
BS○-
BSZ / BSZ-K○○
BSZ-H / BSZ-HK●●
BSS○○
BSS-H●●
Process connection
Type of process connection■ Connection for pipes per DIN 11866 row A, B, C ■ Clamp per DIN 32676 ■ Threaded connection per DIN 11851 ■ Threaded connection per DIN 11864-1 form A ■ Threaded connection NEUMOBioConnect ® Other process connections on request
Neck tube
Neck tube diameter12 mm[0.47 in]
Neck length N (M H )50 mm[1.97 in]
Surface roughness■ R a ≤ 0.76 µm ■ R a ≤ 0.76 µm electropolished ■ R a ≤ 0.38 µm ■ R a ≤ 0.38 µm electropolished
Connection to thermometerScrewed into the connection head (M24 x 1.5)
Material (wetted)Stainless steel
View all (20)
Process connection
Sealing combinationTransition from the connection head to the thermowell/protection tube is effect - ed via version with sealing combination (polyurethane) of flat gasket and wiper
■ Permanently prevents the penetration and depositing of humidity and impurities in this area (IP68) ■ Simplifies cleaning considerably (in combination with the patented BVS head and the hygienic cable gland, an easy to clean and hygienic measur- ing location results, even in non-wetted areas)
Material (wetted)Stainless steel 1.4435 (316L)
Sealing material■ NBR ■ PTFE ■ EPDM
Output signal (transmitter version)
Analogue output
Transmitter models T15, T324 ...20mA
Transmitter model T32HART ® protocol
Factory configuration (transmitter)→ Customer-specific configuration available on request
SensorPt100
Connection method3-wire
Measuring rangeMeasuring range 0 ... 150 °C [32 ... 302 °F]
Other measuring ranges are adjustable
Time response
Response time per IEC 60751t 50 < 3.2 s or t 90 < 7.3 s + response time of the respective transmitter 1) → see data sheet for the respective transmitter
Electrical connection
Connection type■ 1 x Pt100, 3-wire ■ 1 x Pt100, 4-wire
Operating conditions
Ambient temperature range-40 ...+85 °C [-40 ...+185 °F]
Storage temperature range-40 ...+85 °C [-40 ...+185 °F]
Further details on: operating conditions
IP ingress protection per IEC/EN 60529
First index num - berIngress protection / Short descriptionTest parameters
Ingress protections against solid foreign bodies (defined by the 1st index number)
6Dust-tightPer IEC/EN 60529
Ingress protections against water (defined by the 2nd index number)
5Protected against water jetsPer IEC/EN 60529
7 1)Protected against the effects of temporary immersion in waterPer IEC/EN 60529
8 1)Protected against the effects of permanent immersion in waterAs agreed upon
LogoDescriptionRegion
EU declaration of conformityEuropean Union
EMCdirective 1) EN 61326 emission (group 1, class B) and immunity (industrial application)
Pressure Equipment Directive For thermowells/protection tubes > DN 25 [1"] and for the associated marking on the measuring instrument or thermowell/protection tube,WIKA confirms conformity with the Pressure Equip - ment Directive in accordance with the conformity assessment procedure, module H. thermowells/protection tubes with nominal widths of ≤ DN 25 [1"], a CE marking in accord - with the Pressure Equipment Directive (PED) is not permitted and therefore, they are
For ance designed and manufactured without CE marking in line with the applicable sound engineering practice.
UL - only for instrument version without explosion protection Safety (e.g. electr. safety, overpressure, ...)USA and Canada
LogoDescriptionRegion
ATEX directive Hazardous areasEuropean Union
Zone 22 dust II 3D Ex tc IIICTX °C Dc X IECEx - in combination with ATEX Hazardous areasInternational
Zone 21 dust Ex ia IIIC T125 ...T65 °C Db EACEurasian Economic Com-
EMCdirective 3) Hazardous areas
Zone 1 gas 1Ex ib IIC T3/T4/5/T6 Ex n Zone 2 gas 2Ex nA IIC T6 ...T1 Gc X Ex Ukraine Hazardous areas Ex i Zone 0 gas II 1G Ex ia IIC T1 ...T6 Ga Zone 1 gas II 2G Ex ia IIC T1 ...T6 GbUkraine
LogoDescriptionRegion
CCC 2) Hazardous areas - Ex i Zone 0 gas Ex ia IIC T1~T6 GaChina
KCs Hazardous areas Ex i Zone 0 gas Ex ia IIC T4 ...T6 Zone 1 gas Ex ib IIC T4 ...T6Korea
-PESO Hazardous areas Ex i Zone 0 gas Ex ia IIC T1 ...T6 GaIndia
PAC Kazakhstan Metrology, measurement technologyKazakhstan
-MChS Permission for commissioningKazakhstan
-PAC Ukraine Metrology, measurement technologyUkraine
PAC Uzbekistan Metrology, measurement technologyUzbekistan
®3-A 4) Hygienic DesignUSA
FEBRUARY 2021 TYPE EL CLASS IEHEDG 4) Hygienic DesignEuropean Union
Certificates
Certificates■ 2.2 test report ■ 3.1 inspection certificate ■ DAkkS calibration certificate, traceable and accredited in accordance with ISO/IEC 17025 ■ Manufacturer&#x27;s declaration regarding regulation (EC) 1935/2004 ■ Certificate of the surface roughness of wetted parts
Hygienic certificates3-A approvalEHEDG approval
ClampYesYes 2)
BioControl YesYes
DIN 11851Yes 1)Yes 2)
DIN 11864-1YesYes
DIN 11864-2YesYes
DIN 11864-3YesYes
DNFor pipe Outer Ø x wall thick-Dimensions in mm[in]PS in bar [psi] 1) 2) 3)
nessØ D iLØ D
1013 x 1.510 [0.39]71 [2.8]34 [1.34]25 [362.6]
1519 x 1.516 [0.63]71 [2.8]34 [1.34]25 [362.6]
2023 x 1.520 [0.79]71 [2.8]34 [1.34]25 [362.6]
2529 x 1.526 [1.02]71 [2.8]50.5 [1.99]25 [362.6]
3235 x 1.532 [1.26]71 [2.8]50.5 [1.99]25 [362.6]
4041 x 1.538 [1.5]71 [2.8]50.5 [1.99]25 [362.6]
5053 x 1.550 [1.97]71 [2.8]64.0 [2.52]16 [232.1]
DNFor pipeDimensions in mm[in]PS in bar [psi]
Outer Ø x wall thick- nessØ D iLØ D1) 2) 3)
¾"19.05 x 1.6515.75 [0.62]71 [2.8]25 [0.98]25 [362.6]
1"25.4 x 1.6522.1 [0.87]71 [2.8]50.5 [1.99]25 [362.6]
1 ½"38.1 x 1.6534.8 [1.37]71 [2.8]50.5 [1.99]25 [362.6]
2"50.8 x 1.6547.5 [1.87]71 [2.8]64.0 [2.52]16 [232.1]
DNFor pipe Outer Ø x wall thick-Dimensions in mm[in]PS in bar [psi] 1) 2) 3)
nessØ D iLØ D
813.5 x 1.610.3 [0.41]71 [2.8]25 [0.98]25 [362.6]
1017.2 x 1.614.0 [0.55]71 [2.8]25 [0.98]25 [362.6]
1521.3 x 1.618.1 [0.71]71 [2.8]34 [1.34]25 [362.6]
2026.9 x 1.623.7 [0.93]71 [2.8]50.5 [1.99]25 [362.6]
2533.7 x 229.7 [1.17]71 [2.8]50.5 [1.99]25 [362.6]
3242.4 x 238.4 [1.51]71 [2.8]50.5 [1.99]25 [362.6]
4048.3 x 244.3 [1.74]71 [2.8]64.0 [2.52]16 [232.1]
DNFor pipeDimensions in mm[in]PS in bar [psi] 1) 2) 3)
Outer Ø x wall thick- nessØ D iLØ D
½"12.7 x 1.69.5 [0.37]71 [2.8]25 [0.98]25 [362.6]
¾"19.05 x 1.615.85 [0.62]71 [2.8]25 [0.98]25 [362.6]
1"25.4 x 1.622.2 [0.87]71 [2.8]50.5 [1.99]25 [362.6]
1 ½"38.1 x 1.634.9 [0.37]71 [2.8]50.5 [1.99]25 [362.6]
2"50.8 x 1.647.6 [1.87]71 [2.8]64.0 [2.52]16 [232.1]
DNFor pipeDimensions in mm[in]PS in bar [psi] 1) 2)
Outer Ø x wall thick- nessØ D iGLGL
1013 x 1.510 [0.39]Rd 28 x 1/884 [3.31]76 [3.0]40 [580.2]
1519 x 1.516 [0.63]Rd 34 x 1/684 [3.31]76 [3.0]40 [580.2]
2023 x 1.520 [0.79]Rd 44 x 1/684 [3.31]72 [2.84]40 [580.2]
2529 x 1.526 [1.02]Rd 52 x 1/684 [3.31]70 [2.76]40 [580.2]
3235 x 1.532 [1.26]Rd 58 x 1/684 [3.31]70 [2.76]40 [580.2]
4041 x 1.538 [1.5]Rd 65 x 1/684 [3.31]70 [2.76]40 [580.2]
5053 x 1.550 [1.97]Rd 78 x 1/684 [3.31]70 [2.76]25 [362.6]
6570 x 266 [2.6]Rd 95 x 1/688 [3.47]72 [2.84]25 [362.6]
DNFor pipe Outer Ø xDimensions in mm[in]PS in bar [psi] 1) 2)
wall thick- nessØ D iGL
1519 x 1.516 [0.63]M30 x 1.584 [3.31]16 [232.1]
2023 x 1.520 [0.79]M36 x 284 [3.31]16 [232.1]
2529 x 1.526 [1.02]M42 x 284 [3.31]16 [232.1]
3235 x 1.532 [1.26]M52 x 284 [3.31]16 [232.1]
4041 x 1.538 [1.5]M56 x 284 [3.31]16 [232.1]
5053 x 1.550 [1.97]M86 x 284 [3.31]16 [232.1]
6570 x 266 [2.6]M90 x 388 [3.47]16 [232.1]
DNFor pipeDimensions in mm[in]PS in bar [psi] 1) 2)
Outer Ø x wall thicknessØ D iGLGL
1013 x 1.510 [0.39]Rd 28 x 1/884 [3.31]76 [3.0]40 [580.2]
1519 x 1.516 [0.63]Rd 34 x 1/884 [3.31]76 [3.0]40 [580.2]
2023 x 1.520 [0.79]Rd 44 x 1/684 [3.31]74 [2.91]40 [580.2]
2529 x 1.526 [1.02]Rd 52 x 1/684 [3.31]72 [2.84]40 [580.2]
3235 x 1.532 [1.26]Rd 58 x 1/684 [3.31]70 [2.76]40 [580.2]
4041 x 1.538 [1.5]Rd 65 x 1/684 [3.31]70 [2.76]40 [580.2]
5053 x 1.550 [1.97]Rd 78 x 1/684 [3.31]70 [2.76]25 [362.6]
6570 x 266 [2.6]Rd 95 x 1/688 [3.47]72 [2.84]25 [362.6]