AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
TR12-B 1
TR12-B
On order
WIKA · Temperature measurement · Family TR12

Process resistance thermometer

For additional thermowell or basic module
Range
-200…600 °C
Output
4-20mA · HART
Protection
IP66
RoHSGOSTMTSCHSBelGIMUkrSEPROUzstandardCEATEXIECExFMCSAEACEx UkraineINMETROCCCPESOKazInMetrKCs-KOSHAKCKazinMetrEx tb IIIC Db UEx iaD 20 T65/T95/T125Ex iaD 21 T65/T95/T125Ex ia IIC T1...T6 GaEx db IIC T1...T6 GbEx ia IIC T1...T6 Ga/Gb0Ex ia IIC T6 ... T1 Ga X1Ex ia IIC T6 ... T1 Ga XEx ia IIIC T80…T440 °C Da XEx ia IIIC T80…T440 °C Db XEx nA IIC T6…T1 Gc XEx tb IIIC T85°C Db X1 Ex d IIC Gb U1Ex d IIC T6….T4 Gb XII 1G Ex ia IIC T1 ...T6 GaII 1/2G Ex ia IIC T1 ...T6 Ga/GbII 2G Ex ia IIC T1 ...T6 GbII 2 G Ex db IIC T6…T4 GbII 1/2 G Ex db IIC T6…T4 Ga/GbII 2D Ex tb IIIC T85°C DbEx ia IIC T3 ... T6 GaEx ia IIC T3 ... T6 Ga/GbEx ia IIIC T125 ... T65 °C DaEx ia IIIC T125 ... T65 °C Da/DbEx db IIC T1 ... T6 Ga/GbEx ia IIC T1 ~ T6 GaEx ia IIC T1 ~ T6 Ga/GbEx ia IIC T1 ~ T6 GbEx ic IIC T1~T6 GcEx iaD 20/21 T65/T95/T125Ex d IIC T1~T6 GbEx d IIC T1~T6 Ga/GbEx ia IIC T4 ... T6Ex ib IIC T4 ... T6Ex ia IIC T1 ... T6 GaEx ia IIC T1…T6 Ga/GbEx ia IIC T1…T6 GbEx db IIC T1…T6 Ga/GbEx db IIC T1…T6 GbEx d IIC T1...T6 GbEx nA IICT6...T1 GcEx tb IIIC T85°C DbEx ia IIC T3...T6 GaEx ia IIIC T125...T65 °C Da/DbEx ia IIC T4...T6Ex ib IIC T4...T6Ex db IICT1…T6 Ga/GbEx ia IIC T1...T6 GbEx db IIC T1...T6 Ga/GbEx d IIC Gb T6/T5/T4Ex d IIB+H2 Gb T6/T5/T4Ex nA IIC T6...T1 Gc XEx tb IIC Db UEx tb IIC T85°C Db XEx ia IIC T3...T6GaEx ia IIC T1-T6GaEx ic IIC T1-T6Gc
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

Resistance thermometers in this series can be combined with a large number of thermowell designs. The replaceable, centrically spring-loaded measuring insert and its extended spring travel enable combination with the widest range of connection head designs.

A wide variety of possible combinations of sensor, connection head, insertion length, neck length, connection to thermowell etc. are available for the thermometers; suitable for any thermowell dimension and any application.

Operation without thermowell is only recommended in certain applications.

for further approvals see page 2

Fig. left: Process resistance thermometer model TR12-B Fig. right: Basic module model TR12-M

Special features

  • For many variants of temperature transmitters including field transmitter
  • For mounting in all standard thermowell designs
  • Spring-loaded measuring insert (replaceable)
  • Explosion-protected versions (option)
Configurator · Step by step

Build a TR12-M for your task

The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.

Step 1 of 3
Configuration structure· click a highlighted segment to jump to that parameter
Your configuration
  • Electrical approvalWithout
  • Ignition protection typeWithout
  • ZoneWithout
  • Sensor1xPt100, 3-wire
  • Accuracy class of the sensorClass B, IEC 60751
  • Temperature range of selected class-196...+600°C
  • Unit of measureMetric (mm)
  • Neck designNipple-Union-Nipple
  • Connection to housing / headMale thread 1/2 NPT
  • Connection to thermowellMale thread 1/2 NPT
  • Neck length [N/MH]150
  • Insertion length [A/L1/U2]—
  • Diameter measuring insert—
  • Sheath material measuring insert—
  • Mechanical requirementsWithout
  • CertificatesWithout
AI suggestion by parameters

Finish your configuration

Select every option to submit the request.

Send request
Send request