WIKA · Temperature measurement · Family TIF
Field case for temperature transmitter
Field case for temperature transmitter with various case variants and explosion-protected options.
Output
4-20mA · HART
Protection
IP66
RoHSEMCChina RoHSEU declaration of conformityCEEx ia IIC T4/T5/T6 GaEx ia IIC T4/T5/T6 GbEx ib IIC T4/T5/T6 GbEx ia [ia Ga] IIC T4/T5/T6 GbEx ia IIIC T135°C DaEx ia IIIC T135°C DbEx ib IIIC T135°C DbII 2G Ex db IIC T4/T5/T6 GbEx db IIC T4/T5/T6 Gb1Ex d IIC T6 ... T4 Gb XII 1G Ex ia IIC T* GaII 2G Ex ia IIC T* GbII 2G Ex ib IIC T* GbII 2(1)G Ex ia [ia Ga] IIC T* GbII 1D Ex ia IIIC T135°C DaII 2D Ex ia IIIC T135°C DbII 2D Ex ib IIIC T135°C DbEx ia [ia Da] IIIC T135 °C Db0 Ex ia IIC T6 ... T4 Ga X1 Ex ia IIC T6 ... T4 Gb X1 Ex ib IIC T6 ... T4 Gb XEx ia IIIC T80 ... T135 °C Da XEx ia IIIC T80 ... T135 °C Db XEx ib IIIC T80 ... T135 °C Db XEx ia [ia Da] IIIC T135°C DbIECExEAC
Price
On request
Depends on configuration
Description
Field cases of this series are available in various case variants. Plastic, stainless steel and aluminium versions can be specified. They can be combined with a large number of temperature transmitters.
Direct wall mounting is the standard fixing method for these field cases. An optional pipe mounting kit is also available for fitting to pipes with a diameter of 1 ... 2".
Fig. left: Field case, round, with screw-on lid
Fig. right: Field case, rectangular
Special features
- Robust case designs
- Numerous connection options
- Large selection of temperature transmitters can be fitted
- Explosion-protected versions
Identification
| Model | TIF11 |
| Product family | TIF |
| Subcategory | Field case |
Accuracy
| Safety integrity level (SIL) | SIL 2 |
Process conditions
| Process connection | M20 x 1.5½ NPT1/2 NPT |
Electrical characteristics
| Output signal | 4-20mA · HART · FOUNDATION™ Fieldbus · PROFIBUS® PA · FOUNDATION Fieldbus · PROFIBUS PA |
Operating environment
| Ambient temperature | −60…+80 °C |
| IP rating | IP66 |
Certifications and approvals
| Certifications | RoHSEMCChina RoHSEU declaration of conformityCE |
| Explosion protection | Ex ia IIC T4/T5/T6 GaEx ia IIC T4/T5/T6 GbEx ib IIC T4/T5/T6 GbEx ia [ia Ga] IIC T4/T5/T6 GbEx ia IIIC T135°C DaEx ia IIIC T135°C DbEx ib IIIC T135°C DbII 2G Ex db IIC T4/T5/T6 GbEx db IIC T4/T5/T6 Gb1Ex d IIC T6 ... T4 Gb XII 1G Ex ia IIC T* GaII 2G Ex ia IIC T* GbII 2G Ex ib IIC T* GbII 2(1)G Ex ia [ia Ga] IIC T* GbII 1D Ex ia IIIC T135°C DaII 2D Ex ia IIIC T135°C DbII 2D Ex ib IIIC T135°C DbII 2(1)D Ex ia [ia Da] IIIC T135 °C DbEx ia [ia Da] IIIC T135 °C Db0 Ex ia IIC T6 ... T4 Ga X1 Ex ia IIC T6 ... T4 Gb X1 Ex ib IIC T6 ... T4 Gb X1 Ex ia [ia Ga] IIC T6 ... T4 Gb XEx ia IIIC T80 ... T135 °C Da XEx ia IIIC T80 ... T135 °C Db XEx ib IIIC T80 ... T135 °C Db XEx ia [ia Da] IIIC T80 ... T135 °C Db XEx i Zone 0, 1, 2 (gas), II 1G Ex ia IIC T* Ga, II 2G Ex ia/ib IIC T* GbEx i Zone 20, 21, 22 (dust), II 1D Ex ia IIIC T135°C Da, II 2D Ex ia/ib IIIC T135°C DbEx d / Ex db IIC T4/T5/T6 Gb, Zone 1 gasIECEx Ex i and Ex d (in conjunction with ATEX)EAC Ex i and Ex d (Hazardous areas)Ex i, intrinsically safe (TIF11-I)Ex d, flameproof enclosure (TIF11-F)IECExEAC |
Additional details
| Datasheet languages | EN |
Tables from datasheet
| Cable entry | Explosion protection | |||
|---|---|---|---|---|
| without | Ex i (gas) Zone 0, 1, 2 | Ex i (dust) Zone 20, 21, 22 | Ex db (gas) Zone 1 | |
| Plastic cable gland | x | x | - | - |
| Plastic cable gland, Ex e (blue) | x | x | x | - |
| Plastic cable gland, Ex e (black) | x | x | x | - |
| Brass cable gland, nickel-plated | x | x | x | - |
| Brass cable gland, nickel-plated, Ex e | x | x | x | - |
| Stainless steel cable gland | x | x | x | - |
| Stainless steel cable gland, Ex e | x | x | x | - |
| Stainless steel cable gland, Ex d | - | - | - | x |
| Plain threaded | x | x | x 2) | x 2) |
| Junction box, M12 x 1 (4-pin) | x | x 1) | - | - |
| Plug screw | x | x | x | x |
| Sealing plugs for transport | not applicable, transport protection |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity ■ EMCdirective 1) EN 61326 emission (group 1, class B) and interference immunity (industrial application) ■ RoHS directive | European Union |
| Logo | Description | Country | ||
|---|---|---|---|---|
| EU declaration of conformity ■ EMCdirective 1) | European Union | |||
| EN 61326 emission (group 1, class B) and interference immunity (industrial application) | ||||
| ■ RoHS directive ■ ATEX directive (option) | ||||
| Hazardous areas | ||||
| - Ex d | Zone 1 gas | II 2G Ex db IIC T4/T5/T6 Gb | ||
| IECEx (option) - in conjunction with ATEX Hazardous areas | International | |||
| - Ex d | Zone 1 gas | Ex db IIC T4/T5/T6 Gb | ||
| EAC (option) Hazardous areas 2) | Eurasian Economic Community | |||
| - Ex d | Zone 1 gas | 1Ex d IIC T6 ...T4 Gb X |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity ■ EMCdirective 1) EN 61326 emission (group 1, class B) and interference immunity (industrial application) | European Union | |
| RoHS directive | ||
| ■ ATEX directive (option) Hazardous areas | ||
| - Ex i Zone Zone Zone Zone Zone Zone Zone | 0 gas II 1G Ex ia IIC T* Ga II 2G Ex ia IIC T* Gb 1 Gb | |
| 1 gas | ||
| 1 II 2G Ex ib IIC T* | ||
| gas Gb mounting to zone 0 gas II 2(1)G Ex ia [ia Ga] IIC T* | ||
| 20 dust II 1D Ex ia IIIC T135°C Da | ||
| 21 dust II 2D Ex ia IIIC T135°C Db | ||
| 21 dust II 2D Ex ib IIIC T135°C Db | ||
| Zone 21 mounting to zone 20 dust II 2(1)D Ex ia [ia Da] IIIC T135 °C |
View all (14)
| Logo | Description | Country | |
|---|---|---|---|
| IECEx (option) - in conjunction with ATEX Hazardous areas | International | ||
| - Ex i Zone Zone Zone Zone Zone Zone Zone Zone | Ex ia IIC T4/T5/T6 Ga Ex ia IIC T4/T5/T6 Gb Ex ib IIC T4/T5/T6 Gb Ex ia [ia Ga] IIC T4/T5/T6 Gb Ex ia IIIC T135°C Da Ex ia IIIC T135°C Db Ex ib IIIC T135°C Db Ex ia [ia Da] IIIC T135 °C Db | ||
| EAC (option) Hazardous areas 2) | Eurasian Economic Community | ||
| - Ex i Zone Zone Zone Zone | 0 Ex ia IIC T6 ...T4 Ga X 1 Ex ia IIC T6 ...T4 Gb X 1 Ex ib IIC T6 ...T4 Gb X 1 Ex ia [ia Ga] IIC T6 ...T4 Gb X |
| Logo | Description |
|---|---|
| - | China RoHS directive |
| Specifications | Case | |
|---|---|---|
| Round, with screw-on lid (head 5/6000 F, 5/6000 S) | Rectangular | |
| Material | ■ Aluminium ■ Stainless steel | ■ Plastic 1) ■ Aluminium ■ Stainless steel |
| Surface | Aluminium: Blue, lacquered (RAL 5022) Stainless steel: Natural finish | Blank |
| Cable outlet thread size | ■ M20 x 1.5 ■ ½NPT | M20 x 1.5 others on request |
| IP ingress protection (max.) | IP66 | IP66 |
| Explosion protection (option) | ■ Ex i ■ Ex d | Ex i |
| Cable entry | For cable Ø | Thread size | Colour | Ingress protection (max.) | Min./max. ambient temperature |
|---|---|---|---|---|---|
| Plastic cable gland | 6 ...10mm | M20 x 1.5 | Black or grey | IP66 | -40 ...+80 °C |
| Plastic cable gland, Ex e | 6 ...10mm | M20 x 1.5 | Light blue | IP66 | -20 ...+80 °C (standard) -40 ...+70 °C (option) |
| Plastic cable gland, Ex e | 6 ...10mm | M20 x 1.5 | Black | IP66 | -20 ...+80 °C (standard) -40 ...+70 °C (option) |
| Brass cable gland, nickel-plated | 6 ...12mm | M20 x 1.5 or½NPT | Blank | IP66 | -60 1) / -40 ...+80 °C |
| Brass cable gland, nickel-plated, Ex e | 6 ...12mm | M20 x 1.5 or½NPT | Blank | IP66 | -60 1) / -40 ...+80 °C |
| Stainless steel cable gland | 7 ...12mm | M20 x 1.5 or½NPT | Blank | IP66 | -60 1) / -40 ...+80 °C |
| Stainless steel cable gland, Ex e | 7 ...12mm | M20 x 1.5 or½NPT | Blank | IP66 | -60 1) / -40 ...+80 °C |
| Stainless steel cable gland, Ex d | 7 ...12mm | M20 x 1.5 or½NPT | Blank | IP66 | -60 1) / -40 ...+80 °C |
| Plain threaded | - | M20 x 1.5 or½NPT | - | IP00 | - |
| Junction box, M12 x 1 (4-pin) | - | M20 x 1.5 | - | IP65 | -40 ...+80 °C |
| Plug screw | - | M20 x 1.5 or½NPT | Blank | IP66 | -60 ...+80 °C |
| Sealing plugs for transport | - | M20 x 1.5 or½NPT | Transparent | - | -40 ...+80 °C |
| Cable entry | For cable Ø | Thread size | Colour | Ingress protection (max.) | Min./max. ambient temperature |
|---|---|---|---|---|---|
| Plastic cable gland | 6 ...10mm | M20 x 1.5 | Black or grey | IP66 | -40 ...+80 °C |
| Plastic cable gland, Ex e | 6 ...10mm | M20 x 1.5 | Light blue | IP66 | -20 ...+80 °C (standard) -40 ...+70 °C (option) |
| Plastic cable gland, Ex e | 6 ...10mm | M20 x 1.5 | Black | IP66 | -20 ...+80 °C (standard) -40 ...+70 °C (option) |
| Brass cable gland, nickel-plated | 6 ...12mm | M20 x 1.5 | Blank | IP66 | -60 1) / -40 ...+80 °C |
| Brass cable gland, nickel-plated, Ex e | 6 ...12mm | M20 x 1.5 | Blank | IP66 | -60 1) / -40 ...+80 °C |
| Stainless steel cable gland | 7 ...12mm | M20 x 1.5 | Blank | IP66 | -60 1) / -40 ...+80 °C |
| Stainless steel cable gland, Ex e | 7 ...12mm | M20 x 1.5 | Blank | IP66 | -60 1) / -40 ...+80 °C |
| Plain threaded | - | M20 x 1.5 | - | IP00 | - |
| Junction box, M12 x 1 (4-pin) | - | M20 x 1.5 | - | IP65 | -40 ...+80 °C |
| Plug screw | - | M20 x 1.5 | Blank | IP66 | -60 ...+80 °C |
| Sealing plugs for transport | - | M20 x 1.5 | Transparent | - | -40 ...+80 °C |
Output signal 4 ... 20 mA, HART ® protocol, FOUNDATION™ Fieldbus and PROFIBUS ® PA
| Transmitter (selectable versions) | Model T15 (for RTD) | Model T16 (for TC) | Model T32 | Model T53 |
|---|---|---|---|---|
| Data sheet | TE 15.01 | TE 16.01 | TE 32.04 | TE 53.01 |
| Output | ||||
| 4 ...20mA | x | x | x | - |
| HART ® protocol | - | - | x | - |
| FOUNDATION™ Fieldbus and PROFIBUS ® PA | - | - | - | x |
| Explosion protection | Optional | Optional | Optional | Standard |
| Model | Description | Order number |
|---|---|---|
| Programming unit Model PU-548 | ■ Easy to use ■ LED status display ■ Compact design ■ No further voltage supply needed, neither for the programming unit nor for the transmitter ■ Incl.1 model magWIK magnetic quick connector | 14231581 |
| Magnetic quick connector magWIK | ■ Replacement for crocodile clips and HART ® terminals ■ Fast, safe and tight electrical connection ■ For all configuration and calibration processes | 14026893 |
| Model | Description | Order number |
|---|---|---|
| Programming unit, model PU-H | ||
| VIATOR ® HART ® USB | HART ® modem for USB interface | 11025166 |
| VIATOR ® HART ® USB PowerXpress™ | HART ® modem for USB interface | 14133234 |
| VIATOR ® HART ® RS-232 | HART ® modem for RS-232 interface | 7957522 |
| VIATOR ® HART ® Bluetooth ® Ex | HART ® modem for Bluetooth interface, Ex | 11364254 |
| Magnetic quick connector magWIK | ■ Replacement for crocodile clips and HART ® terminals ■ Fast, safe and tight electrical connection ■ For all configuration and calibration processes | 14026893 |
| Model | Description | Order number |
|---|---|---|
| Adapter | ■ Suitable forTS 35 per DIN EN 60715 (DIN EN 50022) orTS 32 per DIN EN 50035 for mounting on a DIN rail ■ Material: Plastic / stainless steel ■ Dimensions: 60 x 20 x 41.6mm | 3593789 |
| Adapter | ■ Suitable forTS 35 per DIN EN 60715 (DIN EN 50022) for mounting on a DIN rail (2 adapters required per transmitter) ■ Material: Steel, tin-plated ■ Dimensions:49x8x14mm | 3619851 |
| Certification type | Measuring accuracy of the built-in transmitter | Material certificate |
|---|---|---|
| 2.2 test report | x | - |
| 3.1 inspection certificate | x | - |
| DKD/DAkkS calibration certificate | x | - |
Industry
Energy
Energy and power plant technology
Industry
Oil & Gas
Chemical industry, oil and gas
Industry
Chemistry / Pharma
Process engineering
Industry
Machinery
Plant construction
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →