AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
TIF11 1
TIF11
On order
WIKA · Temperature measurement · Family TIF

Field case for temperature transmitter

Field case for temperature transmitter with various case variants and explosion-protected options.
Output
4-20mA · HART
Protection
IP66
RoHSEMCChina RoHSEU declaration of conformityCEEx ia IIC T4/T5/T6 GaEx ia IIC T4/T5/T6 GbEx ib IIC T4/T5/T6 GbEx ia [ia Ga] IIC T4/T5/T6 GbEx ia IIIC T135°C DaEx ia IIIC T135°C DbEx ib IIIC T135°C DbII 2G Ex db IIC T4/T5/T6 GbEx db IIC T4/T5/T6 Gb1Ex d IIC T6 ... T4 Gb XII 1G Ex ia IIC T* GaII 2G Ex ia IIC T* GbII 2G Ex ib IIC T* GbII 2(1)G Ex ia [ia Ga] IIC T* GbII 1D Ex ia IIIC T135°C DaII 2D Ex ia IIIC T135°C DbII 2D Ex ib IIIC T135°C DbEx ia [ia Da] IIIC T135 °C Db0 Ex ia IIC T6 ... T4 Ga X1 Ex ia IIC T6 ... T4 Gb X1 Ex ib IIC T6 ... T4 Gb XEx ia IIIC T80 ... T135 °C Da XEx ia IIIC T80 ... T135 °C Db XEx ib IIIC T80 ... T135 °C Db XEx ia [ia Da] IIIC T135°C DbIECExEAC
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

Field cases of this series are available in various case variants. Plastic, stainless steel and aluminium versions can be specified. They can be combined with a large number of temperature transmitters.

Direct wall mounting is the standard fixing method for these field cases. An optional pipe mounting kit is also available for fitting to pipes with a diameter of 1 ... 2".

Fig. left: Field case, round, with screw-on lid

Fig. right: Field case, rectangular

Special features

  • Robust case designs
  • Numerous connection options
  • Large selection of temperature transmitters can be fitted
  • Explosion-protected versions
Identification
ModelTIF11
Product familyTIF
SubcategoryField case
Accuracy
Safety integrity level (SIL)SIL 2
Process conditions
Process connection
M20 x 1.5½ NPT1/2 NPT
Electrical characteristics
Output signal4-20mA · HART · FOUNDATION™ Fieldbus · PROFIBUS® PA · FOUNDATION Fieldbus · PROFIBUS PA
Operating environment
Ambient temperature−60…+80 °C
IP ratingIP66
Certifications and approvals
Certifications
RoHSEMCChina RoHSEU declaration of conformityCE
Explosion protection
Ex ia IIC T4/T5/T6 GaEx ia IIC T4/T5/T6 GbEx ib IIC T4/T5/T6 GbEx ia [ia Ga] IIC T4/T5/T6 GbEx ia IIIC T135°C DaEx ia IIIC T135°C DbEx ib IIIC T135°C DbII 2G Ex db IIC T4/T5/T6 GbEx db IIC T4/T5/T6 Gb1Ex d IIC T6 ... T4 Gb XII 1G Ex ia IIC T* GaII 2G Ex ia IIC T* GbII 2G Ex ib IIC T* GbII 2(1)G Ex ia [ia Ga] IIC T* GbII 1D Ex ia IIIC T135°C DaII 2D Ex ia IIIC T135°C DbII 2D Ex ib IIIC T135°C DbII 2(1)D Ex ia [ia Da] IIIC T135 °C DbEx ia [ia Da] IIIC T135 °C Db0 Ex ia IIC T6 ... T4 Ga X1 Ex ia IIC T6 ... T4 Gb X1 Ex ib IIC T6 ... T4 Gb X1 Ex ia [ia Ga] IIC T6 ... T4 Gb XEx ia IIIC T80 ... T135 °C Da XEx ia IIIC T80 ... T135 °C Db XEx ib IIIC T80 ... T135 °C Db XEx ia [ia Da] IIIC T80 ... T135 °C Db XEx i Zone 0, 1, 2 (gas), II 1G Ex ia IIC T* Ga, II 2G Ex ia/ib IIC T* GbEx i Zone 20, 21, 22 (dust), II 1D Ex ia IIIC T135°C Da, II 2D Ex ia/ib IIIC T135°C DbEx d / Ex db IIC T4/T5/T6 Gb, Zone 1 gasIECEx Ex i and Ex d (in conjunction with ATEX)EAC Ex i and Ex d (Hazardous areas)Ex i, intrinsically safe (TIF11-I)Ex d, flameproof enclosure (TIF11-F)IECExEAC
Additional details
Datasheet languagesEN
Tables from datasheet
Cable entryExplosion protection
withoutEx i (gas) Zone 0, 1, 2Ex i (dust) Zone 20, 21, 22Ex db (gas) Zone 1
Plastic cable glandxx--
Plastic cable gland, Ex e (blue)xxx-
Plastic cable gland, Ex e (black)xxx-
Brass cable gland, nickel-platedxxx-
Brass cable gland, nickel-plated, Ex exxx-
Stainless steel cable glandxxx-
Stainless steel cable gland, Ex exxx-
Stainless steel cable gland, Ex d---x
Plain threadedxxx 2)x 2)
Junction box, M12 x 1 (4-pin)xx 1)--
Plug screwxxxx
Sealing plugs for transportnot applicable, transport protection
LogoDescriptionCountry
EU declaration of conformity ■ EMCdirective 1) EN 61326 emission (group 1, class B) and interference immunity (industrial application) ■ RoHS directiveEuropean Union
LogoDescriptionCountry
EU declaration of conformity ■ EMCdirective 1)European Union
EN 61326 emission (group 1, class B) and interference immunity (industrial application)
■ RoHS directive ■ ATEX directive (option)
Hazardous areas
- Ex dZone 1 gasII 2G Ex db IIC T4/T5/T6 Gb
IECEx (option) - in conjunction with ATEX Hazardous areasInternational
- Ex dZone 1 gasEx db IIC T4/T5/T6 Gb
EAC (option) Hazardous areas 2)Eurasian Economic Community
- Ex dZone 1 gas1Ex d IIC T6 ...T4 Gb X
LogoDescriptionCountry
EU declaration of conformity ■ EMCdirective 1) EN 61326 emission (group 1, class B) and interference immunity (industrial application)European Union
RoHS directive
■ ATEX directive (option) Hazardous areas
- Ex i Zone Zone Zone Zone Zone Zone Zone0 gas II 1G Ex ia IIC T* Ga II 2G Ex ia IIC T* Gb 1 Gb
1 gas
1 II 2G Ex ib IIC T*
gas Gb mounting to zone 0 gas II 2(1)G Ex ia [ia Ga] IIC T*
20 dust II 1D Ex ia IIIC T135°C Da
21 dust II 2D Ex ia IIIC T135°C Db
21 dust II 2D Ex ib IIIC T135°C Db
Zone 21 mounting to zone 20 dust II 2(1)D Ex ia [ia Da] IIIC T135 °C
View all (14)
LogoDescriptionCountry
IECEx (option) - in conjunction with ATEX Hazardous areasInternational
- Ex i Zone Zone Zone Zone Zone Zone Zone ZoneEx ia IIC T4/T5/T6 Ga Ex ia IIC T4/T5/T6 Gb Ex ib IIC T4/T5/T6 Gb Ex ia [ia Ga] IIC T4/T5/T6 Gb Ex ia IIIC T135°C Da Ex ia IIIC T135°C Db Ex ib IIIC T135°C Db Ex ia [ia Da] IIIC T135 °C Db
EAC (option) Hazardous areas 2)Eurasian Economic Community
- Ex i Zone Zone Zone Zone0 Ex ia IIC T6 ...T4 Ga X 1 Ex ia IIC T6 ...T4 Gb X 1 Ex ib IIC T6 ...T4 Gb X 1 Ex ia [ia Ga] IIC T6 ...T4 Gb X
LogoDescription
-China RoHS directive
SpecificationsCase
Round, with screw-on lid (head 5/6000 F, 5/6000 S)Rectangular
Material■ Aluminium ■ Stainless steel■ Plastic 1) ■ Aluminium ■ Stainless steel
SurfaceAluminium: Blue, lacquered (RAL 5022) Stainless steel: Natural finishBlank
Cable outlet thread size■ M20 x 1.5 ■ ½NPTM20 x 1.5 others on request
IP ingress protection (max.)IP66IP66
Explosion protection (option)■ Ex i ■ Ex dEx i
Cable entryFor cable ØThread sizeColourIngress protection (max.)Min./max. ambient temperature
Plastic cable gland6 ...10mmM20 x 1.5Black or greyIP66-40 ...+80 °C
Plastic cable gland, Ex e6 ...10mmM20 x 1.5Light blueIP66-20 ...+80 °C (standard) -40 ...+70 °C (option)
Plastic cable gland, Ex e6 ...10mmM20 x 1.5BlackIP66-20 ...+80 °C (standard) -40 ...+70 °C (option)
Brass cable gland, nickel-plated6 ...12mmM20 x 1.5 or½NPTBlankIP66-60 1) / -40 ...+80 °C
Brass cable gland, nickel-plated, Ex e6 ...12mmM20 x 1.5 or½NPTBlankIP66-60 1) / -40 ...+80 °C
Stainless steel cable gland7 ...12mmM20 x 1.5 or½NPTBlankIP66-60 1) / -40 ...+80 °C
Stainless steel cable gland, Ex e7 ...12mmM20 x 1.5 or½NPTBlankIP66-60 1) / -40 ...+80 °C
Stainless steel cable gland, Ex d7 ...12mmM20 x 1.5 or½NPTBlankIP66-60 1) / -40 ...+80 °C
Plain threaded-M20 x 1.5 or½NPT-IP00-
Junction box, M12 x 1 (4-pin)-M20 x 1.5-IP65-40 ...+80 °C
Plug screw-M20 x 1.5 or½NPTBlankIP66-60 ...+80 °C
Sealing plugs for transport-M20 x 1.5 or½NPTTransparent--40 ...+80 °C
Cable entryFor cable ØThread sizeColourIngress protection (max.)Min./max. ambient temperature
Plastic cable gland6 ...10mmM20 x 1.5Black or greyIP66-40 ...+80 °C
Plastic cable gland, Ex e6 ...10mmM20 x 1.5Light blueIP66-20 ...+80 °C (standard) -40 ...+70 °C (option)
Plastic cable gland, Ex e6 ...10mmM20 x 1.5BlackIP66-20 ...+80 °C (standard) -40 ...+70 °C (option)
Brass cable gland, nickel-plated6 ...12mmM20 x 1.5BlankIP66-60 1) / -40 ...+80 °C
Brass cable gland, nickel-plated, Ex e6 ...12mmM20 x 1.5BlankIP66-60 1) / -40 ...+80 °C
Stainless steel cable gland7 ...12mmM20 x 1.5BlankIP66-60 1) / -40 ...+80 °C
Stainless steel cable gland, Ex e7 ...12mmM20 x 1.5BlankIP66-60 1) / -40 ...+80 °C
Plain threaded-M20 x 1.5-IP00-
Junction box, M12 x 1 (4-pin)-M20 x 1.5-IP65-40 ...+80 °C
Plug screw-M20 x 1.5BlankIP66-60 ...+80 °C
Sealing plugs for transport-M20 x 1.5Transparent--40 ...+80 °C
Output signal 4 ... 20 mA, HART ® protocol, FOUNDATION™ Fieldbus and PROFIBUS ® PA
Transmitter (selectable versions)Model T15 (for RTD)Model T16 (for TC)Model T32Model T53
Data sheetTE 15.01TE 16.01TE 32.04TE 53.01
Output
4 ...20mAxxx-
HART ® protocol--x-
FOUNDATION™ Fieldbus and PROFIBUS ® PA---x
Explosion protectionOptionalOptionalOptionalStandard
ModelDescriptionOrder number
Programming unit Model PU-548■ Easy to use ■ LED status display ■ Compact design ■ No further voltage supply needed, neither for the programming unit nor for the transmitter ■ Incl.1 model magWIK magnetic quick connector14231581
Magnetic quick connector magWIK■ Replacement for crocodile clips and HART ® terminals ■ Fast, safe and tight electrical connection ■ For all configuration and calibration processes14026893
ModelDescriptionOrder number
Programming unit, model PU-H
VIATOR ® HART ® USBHART ® modem for USB interface11025166
VIATOR ® HART ® USB PowerXpress™HART ® modem for USB interface14133234
VIATOR ® HART ® RS-232HART ® modem for RS-232 interface7957522
VIATOR ® HART ® Bluetooth ® ExHART ® modem for Bluetooth interface, Ex11364254
Magnetic quick connector magWIK■ Replacement for crocodile clips and HART ® terminals ■ Fast, safe and tight electrical connection ■ For all configuration and calibration processes14026893
ModelDescriptionOrder number
Adapter■ Suitable forTS 35 per DIN EN 60715 (DIN EN 50022) orTS 32 per DIN EN 50035 for mounting on a DIN rail ■ Material: Plastic / stainless steel ■ Dimensions: 60 x 20 x 41.6mm3593789
Adapter■ Suitable forTS 35 per DIN EN 60715 (DIN EN 50022) for mounting on a DIN rail (2 adapters required per transmitter) ■ Material: Steel, tin-plated ■ Dimensions:49x8x14mm3619851
Certification typeMeasuring accuracy of the built-in transmitterMaterial certificate
2.2 test reportx-
3.1 inspection certificatex-
DKD/DAkkS calibration certificatex-