High-temperature thermometer
Description
Thermocouples of the TC80 model series have been developed to measure extremely high temperatures. These high-temperature thermocouples comply with DIN EN 50446. The thermocouple wires of the thermocouple which is built into the protection tube, are fed into either capillary bores in ceramic insulation tubes or into capillary bores in insulation rods. A protection tube, mostly from highly heat-resistant metal or high temperature ceramic, with or without additional inner tube, protects the thermocouple from the process medium as well as from mechanical and chemical damage.
A wide selection of process connections, e.g. stop flanges, threaded bushings and solid welded flanges enable direct mounting into the process. For particularly critical
for further approvals see page 12
Special features
- Application ranges up to max. 1,600 °C [2,912 °F] (DIN EN 50446)
- Thermowell made of heat-resistant steel or ceramic, also with ceramic inner tube
- Support tube of carbon steel
- Gastight process connection
- Coating (optional)
| Model | TC80 |
| Subcategory | Straight thermocouple |
| Temperature ranges | −40…+750 °C · +0…+1600 °C · +600…+1700 °C · −40…+1000 °C · −40…+1200 °C · +0…+1260 °C · −40…+800 °C · −40…+900 °C · +0…+870 °C · +0…+760 °C · +0…+1480 °C · +870…+1700 °C |
| Process connection | threaded bushingstop flangemating flangefixed-welded flangeSolid welded flangeG 1NPTG 1½G ½G ¾M20x1.5M27x2G 1 1/4 |
| Process temperature | +0…+1700 °C |
| Output signal | HART · PROFIBUS PA · FOUNDATION Fieldbus · FOUNDATION™ Fieldbus · 4-20mA |
| Electrical connection | M20 x 1.5 |
| Probe material | C 530, C 610, C 799, heat-resistant steel, ceramic |
| Thermowell material | heat-resistant steel, ceramic, C 530, C 610, C 799, carbon steel, stainless steel, Metal |
| IP rating | IP53 |
| Certifications | EACCEGOSTKazInMetrMTSCHSBelGIMUzstandard |
| Sensor type | Type K/J/T/N/S/R/B |
| Sensor class | Class 1/2 |
| Probe length | 2000 mm |
| Probe diameter | 26 mm |
| Thermowell | Yes |
| Thermowell form | Form A/ C |
| Datasheet languages | EN, DE |
| Type | Tolerance value | Class | Temperature range |
|---|---|---|---|
| K N | IEC 60584-1 | 1 | -40 ... +1,000 °C |
| 2 | -40 ... +1,200 °C | ||
| ASTM E230 | Special | 0 ... 1,260 °C | |
| Standard | 0 ... 1,260 °C | ||
| J | IEC 60584-1 | 1 | -40 ...+750 °C |
| 2 | -40 ...+750 °C | ||
| ASTM E230 | Special | 0 ... 760 °C | |
| Standard | 0 ... 760 °C | ||
| E | IEC 60584-1 | 1 | -40 ...+800 °C |
| 2 | -40 ...+900 °C | ||
| ASTM E230 | Special | 0 ... 870 °C | |
| Standard | 0 ... 870 °C | ||
| R S | IEC 60584-1 | 1 | 0 ... 1,600 °C |
| 2 | 0 ... 1,600 °C | ||
| ASTM E230 | Special | 0 ... 1,480 °C | |
| Standard | 0 ... 1,480 °C | ||
| B | IEC 60584-1 | 2 | 600 ... 1,700 °C |
| 3 | 600 ... 1,700 °C | ||
| ASTM E230 | Special | - | |
| Standard | 870 ... 1,700 °C |
| Model | Material | Cable outlet | Ingress protection | Cap | Surface |
|---|---|---|---|---|---|
| BS | Aluminium | M20 x 1.5 1) | IP53 | Cap with 2 screws | Blue, lacquered 2) |
| BSZ | Aluminium | M20 x 1.5 1) | IP53 | Hinged cover with cylinder head screw | Blue, lacquered 2) |
| BSZ-H | Aluminium | M20 x 1.5 1) | IP53 | Hinged cover with cylinder head screw | Blue, lacquered 2) |
| BSS | Aluminium | M20 x 1.5 1) | IP53 | Hinged cover with clip | Blue, lacquered 2) |
| BSS-H | Aluminium | M20 x 1.5 1) | IP53 | Hinged cover with clip | Blue, lacquered 2) |
| AS | Aluminium | M20 x 1.5 1) | IP53 | Cap with 2 screws | Blue, lacquered 2) |
| ASZ | Aluminium | M20 x 1.5 1) | IP53 | Hinged cover with cylinder head screw | Blue, lacquered 2) |
| ASZ-H | Aluminium | M20 x 1.5 1) | IP53 | Hinged cover with cylinder head screw | Blue, lacquered 2) |
| Connection head | Transmitter model | ||
|---|---|---|---|
| T32 | T91 | T53 | |
| BS | - | - | - |
| BSZ | - | - | - |
| BSZ-H | ● | ● | ● |
| BSS | - | - | - |
| BSS-H | ● | ● | ● |
| AS | - | - | - |
| ASZ | - | - | - |
| ASZ-H | ● | ● | ● |
| Model | Description | Data sheet |
|---|---|---|
| T32 | Digital transmitter, HART ® protocol | TE 32.04 |
| T53 | Digital transmitter FOUNDATION™ Fieldbus and PROFIBUS ® PA | TE 53.01 |
| T91 | Analogue transmitter, fixed measuring range | TE 91.01 |
View all (20)
| Version | Metal protection tube | Ceramic inner tube | |
|---|---|---|---|
| External Ø | Wall thickness | External Ø | |
| Ø F | s | Ø Fi | |
| AM | 22 | 2 | 15 |
| BM | 15 | 2 | 10 |
| Ceramic protection tube | Ceramic inner tube | |
|---|---|---|
| External Ø | Wall thickness | External Ø |
| Ø F | s | Ø Fi |
| 26 | 2 - 4 | 15, 16 |
| 15, 16 | 2 | 10 |
| Version | External Ø | Length |
|---|---|---|
| Ø F 4 | N (L 4 ) | |
| AK | 32 | 200 |
| 22 | 150 | |
| AKK | 32 | 200 |
| 22 | 150 | |
| BK | 15 | 150 |
| Version | Protection tube | Dimensions inmm | Process connection | |
|---|---|---|---|---|
| External Ø | Ø f/f 4 | i min. | E | |
| AM AMK | 22 | 22,5 | 20 | G1, 1 NPT,G1½ |
| BM BMK | 15 | 15,5 | 20 | G½,G¾,G1,1½NPT, M20x1.5,M27x2 |
| Version | Protection tube | Dimensions inmm | |
|---|---|---|---|
| External Ø | Ø f/f 4 | C (hole centre spacing) | |
| AM AMK | 22 | 22.5 | 70 |
| BM BMK | 15 | 15.5 | 55 |
| Version | Protection tube | Dimensions inmm | Process connection | |
|---|---|---|---|---|
| External Ø | Ø f/f 4 | i min. | E | |
| AK | 32 | 32.5 | 30 | G1¼ |
| 22 | 22.5 | 20 | G1, 1 NPT | |
| BK | 15 | 15.5 | 20 | G½,G¾,G1 |
| Version | Protection tube | Dimensions inmm | |
|---|---|---|---|
| External Ø | Ø f/f 4 | C (hole centre spacing) | |
| AK | 32 | 32.5 | 70 |
| 22 | 22.5 | 70 | |
| BK | 15 | 15.5 | 55 |
| Material no. | AISI no. | Applicable in air up to °C | Resistance against | |||
|---|---|---|---|---|---|---|
| Sulphurous gases | Nitrogenous, low-oxygen gases | Carburisation | ||||
| Oxidising | Reducing | |||||
| 1.0305 | - | 550 | Low | Slight | Medium | Slight |
| 1.4571 | 316Ti | 800 | Slight | Slight | Medium | Medium |
| 1.4762 | - | 1,200 | Very high | High | Slight | Medium |
| 1.4749 | 446 | 1,150 | Very high | High | Slight | Medium |
| 1.4841 | 310 / 314 | 1,150 | Very slight | Very slight | High | Slight |
| Material no. | Range of applications |
|---|---|
| 1.0305 (St35.8) | Tempering furnaces for heat treatment plant, galvanising and tinning plant, carbon-dust-air mixture pipelines in steam power stations |
| 1.0305 enamelled (St35.8 enamelled) | Flue-gas desulphurisation plants, babbitt metal, lead and tin smelters |
| 1.4762 X 10 CrAISi 25 | Combustion exhaust gases, cement and ceramic furnaces, heat treatment plants, annealing furnaces |
| 1.4749 X 18 CrNi 28 | Flue gas ducts, annealing furnaces |
| Kanthal Super (molybdenum disilicide) | Glass and ceramic industries, coal liquification, refuse incinerators |
| 1.4841 X 15 CrNiSi 25-21 | Combustion chambers, industrial furnaces, petrochemical industry, cowper stoves, cyanide baths |
| Sensor type | IEC 60584-1 | ASTM E230 | ||
|---|---|---|---|---|
| Positive | Negative | Positive | Negative | |
| K | Green | White | Yellow | Red |
| N | Pink | White | Orange | Red |
| J | Black | White | White | Red |
| S | Orange | White | Black | Red |
| R | Orange | White | Black | Red |
| B | Grey | White | Grey | Red |
| Material no. | Range of applications | |
|---|---|---|
| 1.4841 | Aluminium | Up to 700 °C |
| 1.1003 | Magnesium (magnesium-containing aluminium) | - |
| 1.0305 | Babbitt metal | Up to 600 °C |
| 1.0305 | Lead | Up to 700 °C |
| 1.4841 | Lead | Up to 700 °C |
| 2.4867 | Lead | Up to 700 °C |
| 1.0305 | Zinc | Up to 480 °C |
| 1.4749 | Zinc | Up to 480 °C |
| 1.4762 | Zinc | Up to 480 °C |
| 1.1003 | Zinc | Up to 600 °C |
| 1.0305 | Tin | Up to 650 °C |
| 1.4762 | Copper | Up to 1,250 °C |
| 1.4841 | Copper-zinc alloy | Up to 900 °C |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity EMCdirective 1) | European Community | |
| EAC (option) Electromagnetic compatibility 1) | Eurasian Economic Community | |
| GOST (option) Metrology, measurement technology | Russia | |
| KazInMetr (option) Metrology, measurement technology | Kazakhstan | |
| - | MTSCHS (option) Permission for commissioning | Kazakhstan |
| BelGIM (option) Metrology, measurement technology | Belarus | |
| Uzstandard (option) Metrology, measurement technology | Uzbekistan |
| Certification type | Measuring accuracy | Material certificate |
|---|---|---|
| 2.2 test report | x | x |
| 3.1 inspection certificate | x | x |
| DKD/DAkkS calibration certificate | x | - |
| Type | Operating temperatures per | |||
|---|---|---|---|---|
| IEC 60584-1 | ASTM E230 | |||
| Class 1 | Class 2 | Standard | Special | |
| K | -40 ...+1,000 °C | -40 ...+1,200 °C | 0 ... 1,260 °C | |
| N | -40 ...+1,000 °C | -40 ...+1,200 °C | 0 ... 1,260 °C | |
| R | 0 ... 1,600 °C | 0 ... 1,480 °C | ||
| S | 0 ... 1,600 °C | 0 ... 1,480 °C | ||
| B | - | 600 ... 1,700 °C | 870 ...1,700 °C | - |
| Sensor | IEC 60584-1 | ASTM E230 | ||
|---|---|---|---|---|
| Model | Positive | Negative | Positive | Negative |
| K | Green | White | Yellow | Red |
| N | Pink | White | Orange | Red |
| S | Orange | White | Black | Red |
| R | Orange | White | Black | Red |
| B | Grey | White | Grey | Red |
| Model | Material | Cable entry thread size | Ingress protection | Cap | Surface |
|---|---|---|---|---|---|
| AS | Aluminium | M20 x 1.5 1) | IP53 | Cap with 2 screws | Blue, painted 2) |
| ASZ | Aluminium | M20 x 1.5 1) | IP53 | Hinged cover with cylinder head screw | Blue, painted 2) |
| ASZ-H | Aluminium | M20 x 1.5 1) | IP53 | Hinged cover with cylinder head screw | Blue, painted 2) |
Couldn't find the answer in the documentation? An engineer will reply within a business day.