AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
TC10-L 1
TC10-L
On order
WIKA · Temperature measurement · Family TC10

Thermocouple

For additional thermowell, flameproof enclosure (Ex d)
Range
-40…1200 °C
Output
4-20mA · HART
Protection
IP66
RoHSCEGOSTUkrSEPROMTSCHSBelGIMKazInMetrUzstandardATEXIECExEACINMETRODNOP-MakNIIEMC[Ex tb IIIC T85 °C Db IP66][II 2G Ex db IIC T6 ... T4 Gb][Ex db IIB + H2 T6 … T4 Gb][Ex db IIC T6 … T4 Gb][Ga/Gb Ex d IIC T6…T1 X][1 Ex d IIC T6…T1 Gb X][Ex tb IIIC T80…T440 °C Db X][Ex db IIB + H2 T6 … T4 Gb IP66][Ex db IIC T6 … T4 Gb IP66][Ex db IIB + H2T6 …T4Gb][Ex db IIC T6 …T4Gb][Ga/Gb Ex d IICT6…T1 X][1 Ex d IICT6…T1 Gb X][Ex tb IIICT80…T440 °C Db X][Ex db IIB+H2T6…T4 Gb][Ex db IICT6…T4 Gb]
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

Thermocouples in this series can be combined with a large number of thermowell designs. Use without a thermowell is not permitted.

A wide variety of possible combinations of sensor, connection head, insertion length, neck length, connection to thermowell etc. are available for the thermometers; suitable for almost any thermowell dimension.

for further approvals see page 2

Fig. left: Model TC10-L with connection head 7/8000 Fig. right: Model TC10-L with connection head 1/4000

Special features

  • Sensor ranges from -40 ... +1,200 °C [-40 ... +2,192 °F]
  • Measuring insert replaceable
  • For many thermowell designs
Identification
ModelTC10-L
Product familyTC10
SubcategoryThermocouple with connection head
Measuring range
Temperature ranges−40…+1200 °C · −40…+1000 °C · −40…+750 °C · −40…+900 °C · −40…+800 °C · −40…+350 °C
Accuracy
Safety integrity level (SIL)SIL 2
Process conditions
Process connection
M20 x 1.5M14 x 1.5M18 x 1.5½ NPT¾ NPTG ½ BG ¾ BG ¼ BMounting thread1/2 NPT3/4 NPTG1/2BG3/4BG1/4B
Process temperature−40…+1200 °C
Electrical characteristics
Output signal4-20mA · HART · PROFIBUS PA · FOUNDATION Fieldbus · FOUNDATION™ Fieldbus
Electrical connectionConnection head with terminal block
Materials
Probe material1.4571, 316L, 316
Operating environment
Ambient temperature−60…+80 °C
IP ratingIP66
Certifications and approvals
Certifications
RoHSCEGOSTUkrSEPROMTSCHSBelGIMKazInMetrUzstandardATEXIECExEACINMETRODNOP-MakNIIEMC
Explosion protection
[Ex tb IIIC T85 °C Db IP66]Zone 1 gas [II 2G Ex db IIC T6...T4 Gb][II 2G Ex db IIB + H2 T6 … T4 Gb][II 2G Ex db IIC T6 ... T4 Gb][II 2D Ex tb IIIC T85 °C Db IP66][Ex db IIB + H2 T6 … T4 Gb][Ex db IIC T6 … T4 Gb][Ga/Gb Ex d IIC T6…T1 X][1 Ex d IIC T6…T1 Gb X][Ex tb IIIC T80…T440 °C Db X][Ex db IIB + H2 T6 … T4 Gb IP66][Ex db IIC T6 … T4 Gb IP66]Ex d Zone 1 gas [II 2G Ex db IIB + H2 T6 ...T4 Gb]Zone 21 dust [II 2D Ex tb IIIC T85 °C Db IP66]Ex d Zone 1 gas [Ex db IIB + H2 T6 ...T4 Gb]Zone 1 gas [Ex db IIC T6...T4 Gb]Zone 21 dust [Ex tb IIIC T85 °C Db IP66]Ex d Zone 1 mounting to zone 0 gas [Ga/Gb Ex d IIC T6...T1 X]Zone 1 gas [1 Ex d IIC T6...T1 Gb X]Zone 21 dust [Ex tb IIIC T80...T440 °C Db X]Ex d Zone 1 gas [Ex db IIB + H2 T6 ...T4 Gb IP66]Zone 1 gas [Ex db IIC T6...T4 Gb IP66]
Additional details
Sensor typeType K/J/E/N/T
Probe diameter6 mm
ThermowellYes
Datasheet languagesEN
Tables from datasheet
LogoDescriptionCountry
EU declaration of conformity ■ EMCdirective 1) EN 61326 emission (group 1, class B) and immunity (industrial application) ■ RoHS directiveEuropean Union
IECEx (option) - in conjunction with ATEX Hazardous areasInternational
- Ex d Zone 1 gas Zone 1 gas Zone 21 dust (option) areas Ex d Zone 1 mounting to zone 0 gas[Ex db IIB + H2T6 …T4Gb] [Ex db IIC T6 …T4Gb] 2) [Ex tb IIIC T85 °C Db IP66]
EAC Hazardous - [Ga/Gb Ex d IICT6…T1 X] Zone 1 gas [1 Ex d IICT6…T1 Gb X] Zone 21 dust [Ex tb IIICT80…T440 °C Db X]Eurasian Economic Community
INMETRO (option) Hazardous areas - Ex d Zone 1 gas [Ex db IIB + H2T6 …T4GbIP66] Zone 1 gas [Ex db IIC T6 …T4GbIP66]Brazil
DNOP - MakNII (option) Hazardous areas - Ex d Zone 1 gas [II 2G Ex db IIB+H2T6…T4 Gb] Zone 1 gas [II 2G Ex db IICT6…T4 Gb]Ukraine
GOST (option) Metrology, measurement technologyRussia
KazInMetr (option) Metrology, measurement technologyKazakhstan
-MTSCHS (option) Permission for commissioningKazakhstan
BelGIM (option) Metrology, measurement technologyBelarus
UkrSEPRO Metrology, measurement technologyUkraine
Uzstandard Metrology, measurement technologyUzbekistan
LogoDescription
SIL 2
TypeOperating temperatures of the thermocouple
IEC 60584-1ASTM E230
Class 2Class 1Standard Special
K-40 ... +1,200 °C-40 ... +1,000 °C0 ... 1,260 °C
J-40 ...+750 °C-40 ...+750 °C0 ... 760 °C
E-40 ...+900 °C-40 ...+800 °C0 ... 870 °C
N-40 ... +1,200 °C-40 ... +1,000 °C0 ... 1,260 °C
T-40 ...+350 °C0 ... 370 °C
ModelMaterialCable entry thread sizeIngress protection (max.) 1)Cover / CapSurfaceConnection to neck tube
1/4000 FAluminium½NPT, ¾NPT, M20 x 1.5IP66 4)Screw-on lidBlue, lacquered 2)½NPT
1/4000 SStainless steel½NPT, ¾NPT, M20 x 1.5IP66 4)Screw-on lidBlank½NPT
7/8000WAluminium½NPT, ¾NPT, M20 x 1.5IP66 4)Screw-on lidBlue, lacquered 2)½NPT
7/8000 SStainless steel½NPT, ¾NPT, M20 x 1.5IP66 4)Screw-on lidBlank½NPT
7/8000W/ DIH50 3)Aluminium½NPT, ¾NPT, M20 x 1.5IP66 4)Screw-on lidBlue, lacquered 2)½NPT
7/8000 S / DIH50 3)Stainless steel½NPT, ¾NPT, M20 x 1.5IP66 4)Screw-on lidBlank½NPT
View all (13)
Cable entryCable entry thread size
Ex d cable gland stainless steelM20 x 1.5 or½NPT
Plain threadedM20 x 1.5 or½NPT
Sealing plugs for shippingM20 x 1.5 or½NPT
Cable entryColourIngress protection (max.)Min./max. ambient temperature
Ex d cable gland stainless steelBlankIP66-60 1) / -40 ...+80 °C
Plain threaded-IP00-
Sealing plugs for transportTransparent--40 ...+80 °C
Output signal 4 ... 20 mA, HART ® protocol, FOUNDATION™ Fieldbus and PROFIBUS ® PA
Transmitter (selectable versions)Model T16Model T32Model T53
Data sheetTE 16.01TE 32.04TE 53.01
Output
■ 4 ...20mAxx
■ HART ® protocolx
■ FOUNDATION™ Fieldbus and PROFIBUS ® PAx
Input
■ Thermocouples IEC 60584-1K, J, E, N,TK, J, E, N,TK, J, E, N,T
Explosion protectionOptionalOptionalStandard
Connection headT16T32T53
1/4000 F, 1/4000 S○○○
7/8000 W, 7/8000 S○○○
7/8000W/ DIH50, 7/8000 S / DIH50○○-
Neck tube designDiameterConnection to headConnection to thermowellMaterial
'Nipple-union-nipple' neck tube~22mm ~27mm½NPT ¾NPTMounting thread316
Double threaded hex bushing (tube section)~22mm ~27mm½NPT ¾NPTMounting thread316
Double threaded hex bushing (with hexagonal spanner flats)-M24 x 1.5 /½NPTMounting thread1.4571
Neck tube with counter nut to head14 x 2.5mmM20 x 1.5 (with counter nut)Mounting thread1.4571
Neck tube designDiameterThread to the thermowell
'Nipple-union-nipple' neck tube~22mm½NPT
~27mm¾NPT
Double threaded hex bushing (tube section)~22mm½NPT
~27mm¾NPT
Double threaded hex bushing (with hexagonal spanner flats)-G½B
G¾B
G¼B
½NPT
¾NPT
M14 x 1.5
M18 x 1.5
M20 x 1.5
Neck tube with counter nut to head14 x 2.5mm½NPT
¾NPT
G½B
G¾B
G¼B
M14 x 1.5
M18 x 1.5
M20 x 1.5
Neck tube designNeck lengthMin. / Max. neck length
'Nipple-union-nipple' neck tube150 mm(approx. 6 inch)75 mm(approx. 3 inch) / 250 mm(approx. 10 inch)
Double threaded hex bushing (tube section)50 mm(approx. 2 inch)50 mm(approx. 2 inch) / 250 mm(approx. 10 inch)
Double threaded hex bushing (with hexagonal spanner flats)25mm
Neck tube with counter nut to head150 mm(approx. 6 inch)75 mm(approx. 3 inch) / 250 mm(approx. 10 inch)
Measuring insert diameter Ø d inmmSheath material
3 1)1.4571, 316L 1)
61.4571, 316L 1)
8 (6 mmwith sleeve)1.4571
Version
Standard6 g peak-to-peak, wire-wound measuring resistor or thin film
OptionVibration-resistant probe tip, max. 20 g peak-to-peak, thin-film measuring resistor
Highly vibration-resistant probe tip, max. 50 g peak-to-peak, thin-film measuring resistor
Certification typeMeasurement accuracyMaterial certificate 2)
2.2 test reportxx
3.1 inspection certificatexx
DKD/DAkkS calibration certificatex-