WIKA · Level measurement · Family FLS
Float switch
For the process industry, vertical installation
Range
0…6000 mm
Output
NO · NC
Accuracy
—
Protection
IP66/IP68
CERoHSEACDNV GLABSBureau VeritasLloyd’s RegisterDIBt
Price
On request
Depends on configuration
Special features
- Large range of application due to the simple, proven functional principle
- For harsh operating conditions, long service life
- Operating limits: Operating temperature: T = -50 ... +350 °C Operating pressure: P = Vacuum up to 40 bar Limit density: ρ ≥ 300 kg/m 3
- Operating temperature: T = -50 ... +350 °C
- Operating pressure: P = Vacuum up to 40 bar
- Limit density: ρ ≥ 300 kg/m 3
- Wide variety of different electrical connections, process connections and materials
- Explosion-protected versions