Load pin
Description
Load pins are used for static and dynamic measuring tasks as replacements for non-measuring bolts. They are used to determine tension and/or compression forces.
Load pins of this model are mainly used in hoists and crane systems. They also serve as reliable sensors in industrial weighing technology and in the fields of production automation, machine-building and plant engineering, where they are used, in particular, in pulleys, cable winches, fork or roller bearings. The load pins have also proven themselves in the chemical and petrochemical industries.
The corresponding technical and regional approvals of these force transducers are, of course, available as options.
For further approvals see page 4
Load pin, model F5301
Model F5301 and F53C1 load pins are made of high-strength, corrosion-resistant 1.4542 stainless steel, the properties of which are particularly well-suited to the application areas of the load pins.
As output signals, the common active current and voltage outputs are available (4 … 20 mA, 0 … 10 V). Redundant output signals and CANopen ® protocols are also
possible.
Special features
- Measuring ranges 0 ... 5 kN to 0 ... 200 kN [0 ... 1,124 lbf to 0... 44,962 lbf]
- Corrosion-resistant stainless steel version
- Integrated amplifier
- High long-term stability, high shock and vibration resistance
- Good reproducibility, easy installation
| Model | F5301 |
| Product family | F53 |
| Subcategory | Load pin |
| Force ranges | 0…5 kN · 0…10 kN · 0…20 kN · 0…30 kN · 0…50 kN · 0…100 kN · 0…200 kN · 0…1124 lbf · 0…2248 lbf · 0…4496 lbf · 0…6744 lbf · 0…11240 lbf · 0…22481 lbf · 0…44962 lbf |
| Accuracy class | ±1%F nom |
| Mounting type | Load pin (replaces non-measuring bolts) |
| Output signal | 4 ... 20 mA, 0 ... 10 V, CANopen® |
| Cell material | 1.4542 stainless steel |
| Ambient temperature | −20…+80 °C |
| IP rating | IP67 |
| Certifications | UL |
| Explosion protection | ATEX |
| Cable length | 2 m |
| Model | F5301 and F53C1 with UL approval | ||||||
|---|---|---|---|---|---|---|---|
| Rated force F nom kN | 5 | 10 | 20 | 30 | 50 | 100 | 200 |
| Rated force F nom lbf | 1,124 | 2,248 | 4,496 | 6,744 | 11,240 | 22,481 | 44,962 |
| Relative linearity error d lin 1) | ±1%F nom | ||||||
| Relative repeatability error in unchanged mounting position b rg | ±0.2%F nom | ||||||
| Temperature effect on | |||||||
| the characteristic valueTK c | 0.2%F nom / 10 K | ||||||
| the zero signalTK 0 | 0.2%F nom / 10 K | ||||||
| Force limit F L | 150%F nom | ||||||
| Breaking force F B | 300%F nom | ||||||
| Transverse force effect d Q (signal at 100%F nom under 90°) | ±5%F nom | ||||||
| Rated displacement (typical) s nom | < 0.1 mm[< 0.004 in] | ||||||
| Material of the measuring body | ■ Corrosion-resistant stainless steel, 1.4542, ultrasound-tested 3.1 material ■ With 3.2 material | ||||||
| Rated temperature B T, nom | -20 …+80 °C [-4 ...+176 °F] | ||||||
| Service temperature B T, G | -30 …+80 °C [-22 ...+176 °F] | ||||||
| Storage temperature B T, S | -40 …+85 °C [-40 ...+185 °F] | ||||||
| Electrical connection | ■ Circular connector M12 x 1, 5-pin ■ CANopen ® M12 x 1, 5-pin circular connector | ||||||
| Output signal (rated characteristic value) C nom | ■ 4 …20mA, 2-wire ■ 4 …20mA, 3-wire ■ 2x4…20mA ■ DC 0 …10V, 3-wire ■ 2xDC0…10V ■ CANopen ® Protocol in accordance with CiA ® 301, device profile CiA ® 404, communication services LSS (CiA ® 305), configuration of the instrument address and baud rate Sync/Async, Node/ Lifeguarding, heartbeat; zero and span ±10 %adjustable via entries in the object directory 2) | ||||||
| Current/power consumption | ■ Current output4…20mA 2-wire: signal current ■ Current output4…20mA 3-wire:<8mA ■ Voltage output:<8mA ■ CANopen ® :<1W | ||||||
| Supply voltage UB | ■ DC 9 ...36V for current output ■ DC 13 ...36V for voltage output ■ DC 9 ...36V for CANopen ® | ||||||
| Load | ■ ≤ (UB - 10 V) / 0.024 A for current output ■ > 10 kΩ for voltage output | ||||||
| Reponse time | ≤ 2 ms (within 10 ...90%F nom ) 3) | ||||||
| Ingress protection (per IEC/EN 60529) | |||||||
| Unplugged state | IP66, IP67 | ||||||
| Plugged-in state | IP68, IP69, IP69K | ||||||
| Electrical protection | Reverse polarity protection, overvoltage and short-circuit resistance | ||||||
| Vibration resistance | 20g, 100 h, 50 ... 150 Hz (in accordance with DIN EN 60068-2-6) | ||||||
| Shock resistance | In accordance with DIN EN 60068-2-27 | ||||||
| Immunity | In accordance with DIN EN 61326-1/DIN EN 61326-2-3 (optional EMC-strengthened versions) | ||||||
| Intended use | Indoor and outdoor use, typically at altitudes of up to 2,500 m[8,202.5 ft] above sea level. |
| Model | F53C1 for ATEX/IECEx EX ib 1) | F5301 for signal jump | |||||
|---|---|---|---|---|---|---|---|
| Rated force F nom kN | 5 | 10 | 20 | 30 | 50 | 100 | 200 |
| Rated force F nom lbf | 1.124 | 2.248 | 4.496 | 6.744 | 11.240 | 22.481 | 44.962 |
| Relative linearity error d lin 2) | ±1%F nom | ||||||
| Relative repeatability error in unchanged mounting position b rg | ±0.2%F nom | ||||||
| Temperature effect on | |||||||
| the characteristic valueTK c | 0.2%F nom / 10 K | ||||||
| the zero signalTK 0 | 0.2%F nom / 10 K | ||||||
| Force limit F L | 150%F nom | ||||||
| Breaking force F B | 300%F nom | ||||||
| Transverse force effect d Q (signal at 100%F nom under 90°) | ±5%F nom | ||||||
| Rated displacement (typical) s nom | < 0.1 mm[< 0.004 in] | ||||||
| Material of the measuring body | ■ Corrosion-resistant stainless steel, 1.4542, ultrasound-tested 3.1 material ■ With 3.2 material | ||||||
| Rated temperature B T, nom | -20 …+80 °C [-4 ...+176 °F] | ||||||
| Service temperature B T, G | Ex II 2G Ex ib IIC T4 Gb -25 °C <Tamb < +85 °C Ex II 2G Ex ib IIC T3 Gb -25 °C <Tamb < +100 °C Ex I M2 Ex ib I Mb -25 °C <Tamb < +85 °C Ex II 2G Ex ib IIC T4 Gb -40 °C <Tamb < +85 °C Ex I M2 Ex ib I Mb | -30 …+80 °C [-22 ...+176 °F] | |||||
| Storage temperature B T, S | -40 …+85 °C [-40 ...+185 °F] | ||||||
| Electrical connection | ■ M12 x 1 circular connector, 4-pin ■ Cable gland | ||||||
| Output signal (rated characteristic value) C nom | ■ 4 …20mA, 2-wire | ■ 4 …16mA, 2-wire 3) ■ DC 2 …8V, 3-wire 3) | |||||
| Current/power consumption | ■ Current output4…20mA 2-wire: signal current | ■ Current output4…20mA 2-wire: signal current ■ Current output4…20mA 3-wire:<8mA ■ Voltage output:<8mA | |||||
| Supply voltage UB | DC 10 ...30V for current output | ■ DC 9 ...36V for current output | |||||
| Load | ■ ≤ (UB - 10 V) / 0.024 A for current output ■ > 10 kΩ for voltage output | ||||||
| Reponse time | ≤ 2 ms (within 10 ...90%F nom ) 4) | ||||||
| Ingress protection (per IEC/EN 60529) | |||||||
| Unplugged state | IP67 | IP66, IP67 | |||||
| Plugged-in state | IP68, IP69, IP69K | ||||||
| Electrical protection | Reverse polarity protection, overvoltage and short-circuit resistance | ||||||
| Vibration resistance | 20g, 100 h, 50 ... 150 Hz (in accordance with DIN EN 60068-2-6) | ||||||
| Shock resistance | In accordance with DIN EN 60068-2-27 | ||||||
| Immunity | In accordance with DIN EN 61326-1/DIN EN 61326-2-3 (optional EMC-strengthened versions) |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity | European Union | |
| EMCdirective |
| Rated force in kN | Dimensions inmm | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LA | ØD 1) | L1 | L2 | L3 | A | B | C | E | G | H | ØI | J | |
| 5 | 115.5 | 20 | 10 | 20 | 50.5 | 5 | 10 | 4.0 | 20 | 60 | 36 | 9 | 16 |
| 10 | 125.5 | 25 | 12.5 | 25 | 60.5 | 5 | 10 | 4.5 | 20 | 60 | 36 | 9 | 18 |
| 20 | 135.5 | 30 | 15 | 30 | 72.5 | 6 | 12 | 5.5 | 25 | 80 | 50 | 11 | 22 |
| 30 | 145.5 | 35 | 17.5 | 35 | 82.5 | 6 | 12 | 6 | 25 | 80 | 50 | 11 | 24 |
| 50 | 160.5 | 40 | 22.5 | 40 | 97.5 | 6 | 12 | 6.5 | 25 | 80 | 50 | 11 | 26 |
| 100 | 175.5 | 50 | 23 | 50 | 112.5 | 8 | 16 | 7 | 30 | 100 | 70 | 13 | 33 |
| 200 | 223.5 | 70 | 35 | 70 | 160.5 | 10 | 20 | 10 | 40 | 140 | 100 | 17 | 45 |
View all (20)
| Rated force in lbf | Dimensions in Inch | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| LA | ØD 1) | L1 | L2 | L3 | A | B | C | E | G | H | ØI | J | |
| 1,124 | 4.58 | 0.79 | 0.4 | 0.79 | 1.98 | 0.19 | 0.4 | 0.16 | 0.79 | 2.36 | 1.42 | 0.35 | 0.63 |
| 2,248 | 4.94 | 0.98 | 0.49 | 0.98 | 2.38 | 0.19 | 0.4 | 0.18 | 0.79 | 2.36 | 1.42 | 0.35 | 0.71 |
| 4,496 | 5.33 | 1.18 | 0.59 | 1.18 | 2.85 | 0.24 | 0.47 | 0.22 | 0.98 | 3.15 | 1.96 | 0.43 | 0.87 |
| 6,744 | 5.73 | 1.37 | 0.69 | 1.38 | 3.25 | 0.24 | 0.47 | 0.24 | 0.98 | 3.15 | 1.96 | 0.43 | 0.94 |
| 11,240 | 6.31 | 1.57 | 0.89 | 1.57 | 3.84 | 0.24 | 0.47 | 0.25 | 0.98 | 3.15 | 1.96 | 0.43 | 1.02 |
| 22,481 | 6.90 | 1.96 | 0.91 | 1.97 | 4.43 | 0.24 | 0.63 | 0.28 | 1.18 | 3.94 | 2.76 | 0.51 | 1.30 |
| 44,962 | 8.80 | 2.75 | 1.37 | 2.76 | 6.32 | 0.24 | 0.79 | 0.4 | 1.57 | 5.51 | 3.94 | 0.67 | 1.77 |
| Signal | Description |
|---|---|
| UB | Voltage source for the sensor |
| UB+ | Sensor voltage supply (+) |
| UB- | Sensor voltage supply (-) |
| S+ | Output signal (+) |
| S- | Output signal (-) |
| 0 V | 0V potential |
| Signal | Description |
|---|---|
| A | Ammeter |
| V | Voltmeter |
| + - | Voltage source |
| Switch | |
| Shield (ground) |
| Signal | 4 ... 20 mA, 2-wire | Cable colour |
|---|---|---|
| UB+/S+ | 1 | Brown |
| 0 V/S- | 3 | Black |
| Shield | Case/Connector | - |
| Signal | 4 ... 20 mA, 3-wire | Cable colour |
|---|---|---|
| UB+ | 1 | Brown |
| S+ | 4 | Black |
| 0 V/S- | 3 | Blue |
| Shield | Case/Connector | - |
| Signal | 0 ... 10 V, 3-wire | Cable colour |
|---|---|---|
| UB+ | 1 | Brown |
| S+ | 4 | Black |
| 0 V/S- | 3 | Blue |
| Shield | Case/Connector | - |
| Signal | Description |
|---|---|
| UB | Voltage source for the sensor |
| UB+ | Sensor voltage supply (+) |
| UB- | Sensor voltage supply (-) |
| UR | Voltage source for the signal jump |
| UR+ | Signal jump supply voltage (+) |
| UR- | Signal jump supply voltage (-) |
| S+ | Output signal (+) |
| S- | Output signal (-) |
| 0 V | 0V potential |
| Signal | Description |
|---|---|
| A | Ammeter |
| V | Voltmeter |
| + - | Voltage source |
| Switch | |
| Shield (ground) |
| Signal | 4 ... 20 mA, 2-wire | Cable colour |
|---|---|---|
| UB+/S+ | 1 | Brown |
| 0 V/S- | 3 | Blue |
| UR+ | 2 | White |
| UR- | 4 | Black |
| Shield | Case/Connector | - |
| Signal | 4 ... 20 mA, 3-wire | Cable colour |
|---|---|---|
| UB+ | 1 | Brown |
| 0 V/S- | 3 | Blue |
| UR+ | 2 | White |
| UR- | 3 | Blue |
| S+ | 4 | Black |
| Shield | Case/Connector | - |
| Signal | 0 ... 10 V, 3-wire | Cable colour |
|---|---|---|
| UB+ | 1 | Brown |
| 0 V/S- | 3 | Blue |
| UR+ | 2 | White |
| UR- | 3 | Blue |
| S+ | 4 | Black |
| Shield | Case/Connector | - |
| Signal | Description |
|---|---|
| UB | Voltage source for the sensor |
| UB+ | Sensor voltage supply (+) |
| UB- | Sensor voltage supply (-) |
| UR | Voltage source for the signal jump |
| S- | Output signal (-) |
| CH1 | Channel 1 |
| CH2 | Channel 2 |
| CH1+2 | Channel 1 and channel 2 |
| 0 V | 0V potential |
| Signal | Description |
|---|---|
| A | Ammeter |
| V | Voltmeter |
| + - | Voltage source |
| Switch | |
| Shield (ground) |
| Signal | 4 ... 20 mA, 2-wire | Cable colour |
|---|---|---|
| UB+/S+ (CH1) | 1 | Brown |
| UB+/S+ (CH2) | 2 | White |
| 0 V/S- (CH1) | 3 | Blue |
| 0 V/S- (CH2) | 4 | Black |
| Shield | Case/Connector | - |
| Signal | 4 ... 20 mA, 3-wire | Cable colour |
|---|---|---|
| UB+ (CH1+2) | 1 | Brown |
| 0 V/S- (CH1+2) | 3 | Blue |
| S+ (CH1) | 4 | Black |
| S+ (CH2) | 2 | White |
| Shield | Case/Connector | - |
| Signal | 0 ... 10 V, 3-wire | Cable colour |
|---|---|---|
| UB+ (CH1+2) | 1 | Brown |
| 0 V/S- (CH1+2) | 3 | Blue |
| S+ (CH1) | 4 | Black |
| S+ (CH2) | 2 | White |
| Shield | Case/Connector | - |
Couldn't find the answer in the documentation? An engineer will reply within a business day.