F5301 1
F5301
On order
WIKA · Force measurement · Family F53

Load pin

With thin-film technology up to 200 kN
Range
0…200 kN
Output
4 ... 20 mA, 0 ... 10 V, CANo…
Accuracy
±1%F nom
Protection
IP67
ULATEX
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

Load pins are used for static and dynamic measuring tasks as replacements for non-measuring bolts. They are used to determine tension and/or compression forces.

Load pins of this model are mainly used in hoists and crane systems. They also serve as reliable sensors in industrial weighing technology and in the fields of production automation, machine-building and plant engineering, where they are used, in particular, in pulleys, cable winches, fork or roller bearings. The load pins have also proven themselves in the chemical and petrochemical industries.

The corresponding technical and regional approvals of these force transducers are, of course, available as options.

For further approvals see page 4

Load pin, model F5301

Model F5301 and F53C1 load pins are made of high-strength, corrosion-resistant 1.4542 stainless steel, the properties of which are particularly well-suited to the application areas of the load pins.

As output signals, the common active current and voltage outputs are available (4 … 20 mA, 0 … 10 V). Redundant output signals and CANopen ® protocols are also

possible.

Special features

  • Measuring ranges 0 ... 5 kN to 0 ... 200 kN [0 ... 1,124 lbf to 0... 44,962 lbf]
  • Corrosion-resistant stainless steel version
  • Integrated amplifier
  • High long-term stability, high shock and vibration resistance
  • Good reproducibility, easy installation
Identification
ModelF5301
Product familyF53
SubcategoryLoad pin
Measuring range
Force ranges0…5 kN · 0…10 kN · 0…20 kN · 0…30 kN · 0…50 kN · 0…100 kN · 0…200 kN · 0…1124 lbf · 0…2248 lbf · 0…4496 lbf · 0…6744 lbf · 0…11240 lbf · 0…22481 lbf · 0…44962 lbf
Accuracy
Accuracy class±1%F nom
Process conditions
Mounting typeLoad pin (replaces non-measuring bolts)
Electrical characteristics
Output signal4 ... 20 mA, 0 ... 10 V, CANopen®
Materials
Cell material1.4542 stainless steel
Operating environment
Ambient temperature−20…+80 °C
IP ratingIP67
Certifications and approvals
CertificationsUL
Explosion protectionATEX
Additional details
Cable length2 m
Tables from datasheet
ModelF5301 and F53C1 with UL approval
Rated force F nom kN510203050100200
Rated force F nom lbf1,1242,2484,4966,74411,24022,48144,962
Relative linearity error d lin 1)±1%F nom
Relative repeatability error in unchanged mounting position b rg±0.2%F nom
Temperature effect on
the characteristic valueTK c0.2%F nom / 10 K
the zero signalTK 00.2%F nom / 10 K
Force limit F L150%F nom
Breaking force F B300%F nom
Transverse force effect d Q (signal at 100%F nom under 90°)±5%F nom
Rated displacement (typical) s nom< 0.1 mm[< 0.004 in]
Material of the measuring body■ Corrosion-resistant stainless steel, 1.4542, ultrasound-tested 3.1 material ■ With 3.2 material
Rated temperature B T, nom-20 …+80 °C [-4 ...+176 °F]
Service temperature B T, G-30 …+80 °C [-22 ...+176 °F]
Storage temperature B T, S-40 …+85 °C [-40 ...+185 °F]
Electrical connection■ Circular connector M12 x 1, 5-pin ■ CANopen ® M12 x 1, 5-pin circular connector
Output signal (rated characteristic value) C nom■ 4 …20mA, 2-wire ■ 4 …20mA, 3-wire ■ 2x4…20mA ■ DC 0 …10V, 3-wire ■ 2xDC0…10V ■ CANopen ® Protocol in accordance with CiA ® 301, device profile CiA ® 404, communication services LSS (CiA ® 305), configuration of the instrument address and baud rate Sync/Async, Node/ Lifeguarding, heartbeat; zero and span ±10 %adjustable via entries in the object directory 2)
Current/power consumption■ Current output4…20mA 2-wire: signal current ■ Current output4…20mA 3-wire:<8mA ■ Voltage output:<8mA ■ CANopen ® :<1W
Supply voltage UB■ DC 9 ...36V for current output ■ DC 13 ...36V for voltage output ■ DC 9 ...36V for CANopen ®
Load■ ≤ (UB - 10 V) / 0.024 A for current output ■ > 10 kΩ for voltage output
Reponse time≤ 2 ms (within 10 ...90%F nom ) 3)
Ingress protection (per IEC/EN 60529)
Unplugged stateIP66, IP67
Plugged-in stateIP68, IP69, IP69K
Electrical protectionReverse polarity protection, overvoltage and short-circuit resistance
Vibration resistance20g, 100 h, 50 ... 150 Hz (in accordance with DIN EN 60068-2-6)
Shock resistanceIn accordance with DIN EN 60068-2-27
ImmunityIn accordance with DIN EN 61326-1/DIN EN 61326-2-3 (optional EMC-strengthened versions)
Intended useIndoor and outdoor use, typically at altitudes of up to 2,500 m[8,202.5 ft] above sea level.
ModelF53C1 for ATEX/IECEx EX ib 1)F5301 for signal jump
Rated force F nom kN510203050100200
Rated force F nom lbf1.1242.2484.4966.74411.24022.48144.962
Relative linearity error d lin 2)±1%F nom
Relative repeatability error in unchanged mounting position b rg±0.2%F nom
Temperature effect on
the characteristic valueTK c0.2%F nom / 10 K
the zero signalTK 00.2%F nom / 10 K
Force limit F L150%F nom
Breaking force F B300%F nom
Transverse force effect d Q (signal at 100%F nom under 90°)±5%F nom
Rated displacement (typical) s nom< 0.1 mm[< 0.004 in]
Material of the measuring body■ Corrosion-resistant stainless steel, 1.4542, ultrasound-tested 3.1 material ■ With 3.2 material
Rated temperature B T, nom-20 …+80 °C [-4 ...+176 °F]
Service temperature B T, GEx II 2G Ex ib IIC T4 Gb -25 °C <Tamb < +85 °C Ex II 2G Ex ib IIC T3 Gb -25 °C <Tamb < +100 °C Ex I M2 Ex ib I Mb -25 °C <Tamb < +85 °C Ex II 2G Ex ib IIC T4 Gb -40 °C <Tamb < +85 °C Ex I M2 Ex ib I Mb-30 …+80 °C [-22 ...+176 °F]
Storage temperature B T, S-40 …+85 °C [-40 ...+185 °F]
Electrical connection■ M12 x 1 circular connector, 4-pin ■ Cable gland
Output signal (rated characteristic value) C nom■ 4 …20mA, 2-wire■ 4 …16mA, 2-wire 3) ■ DC 2 …8V, 3-wire 3)
Current/power consumption■ Current output4…20mA 2-wire: signal current■ Current output4…20mA 2-wire: signal current ■ Current output4…20mA 3-wire:<8mA ■ Voltage output:<8mA
Supply voltage UBDC 10 ...30V for current output■ DC 9 ...36V for current output
Load■ ≤ (UB - 10 V) / 0.024 A for current output ■ > 10 kΩ for voltage output
Reponse time≤ 2 ms (within 10 ...90%F nom ) 4)
Ingress protection (per IEC/EN 60529)
Unplugged stateIP67IP66, IP67
Plugged-in stateIP68, IP69, IP69K
Electrical protectionReverse polarity protection, overvoltage and short-circuit resistance
Vibration resistance20g, 100 h, 50 ... 150 Hz (in accordance with DIN EN 60068-2-6)
Shock resistanceIn accordance with DIN EN 60068-2-27
ImmunityIn accordance with DIN EN 61326-1/DIN EN 61326-2-3 (optional EMC-strengthened versions)
LogoDescriptionRegion
EU declaration of conformityEuropean Union
EMCdirective
Rated force in kNDimensions inmm
LAØD 1)L1L2L3ABCEGHØIJ
5115.520102050.55104.0206036916
10125.52512.52560.55104.5206036918
20135.530153072.56125.52580501122
30145.53517.53582.561262580501124
50160.54022.54097.56126.52580501126
100175.5502350112.5816730100701333
200223.5703570160.5102010401401001745
View all (20)
Rated force in lbfDimensions in Inch
LAØD 1)L1L2L3ABCEGHØIJ
1,1244.580.790.40.791.980.190.40.160.792.361.420.350.63
2,2484.940.980.490.982.380.190.40.180.792.361.420.350.71
4,4965.331.180.591.182.850.240.470.220.983.151.960.430.87
6,7445.731.370.691.383.250.240.470.240.983.151.960.430.94
11,2406.311.570.891.573.840.240.470.250.983.151.960.431.02
22,4816.901.960.911.974.430.240.630.281.183.942.760.511.30
44,9628.802.751.372.766.320.240.790.41.575.513.940.671.77
SignalDescription
UBVoltage source for the sensor
UB+Sensor voltage supply (+)
UB-Sensor voltage supply (-)
S+Output signal (+)
S-Output signal (-)
0 V0V potential
SignalDescription
AAmmeter
VVoltmeter
+ -Voltage source
Switch
Shield (ground)
Signal4 ... 20 mA, 2-wireCable colour
UB+/S+1Brown
0 V/S-3Black
ShieldCase/Connector-
Signal4 ... 20 mA, 3-wireCable colour
UB+1Brown
S+4Black
0 V/S-3Blue
ShieldCase/Connector-
Signal0 ... 10 V, 3-wireCable colour
UB+1Brown
S+4Black
0 V/S-3Blue
ShieldCase/Connector-
SignalDescription
UBVoltage source for the sensor
UB+Sensor voltage supply (+)
UB-Sensor voltage supply (-)
URVoltage source for the signal jump
UR+Signal jump supply voltage (+)
UR-Signal jump supply voltage (-)
S+Output signal (+)
S-Output signal (-)
0 V0V potential
SignalDescription
AAmmeter
VVoltmeter
+ -Voltage source
Switch
Shield (ground)
Signal4 ... 20 mA, 2-wireCable colour
UB+/S+1Brown
0 V/S-3Blue
UR+2White
UR-4Black
ShieldCase/Connector-
Signal4 ... 20 mA, 3-wireCable colour
UB+1Brown
0 V/S-3Blue
UR+2White
UR-3Blue
S+4Black
ShieldCase/Connector-
Signal0 ... 10 V, 3-wireCable colour
UB+1Brown
0 V/S-3Blue
UR+2White
UR-3Blue
S+4Black
ShieldCase/Connector-
SignalDescription
UBVoltage source for the sensor
UB+Sensor voltage supply (+)
UB-Sensor voltage supply (-)
URVoltage source for the signal jump
S-Output signal (-)
CH1Channel 1
CH2Channel 2
CH1+2Channel 1 and channel 2
0 V0V potential
SignalDescription
AAmmeter
VVoltmeter
+ -Voltage source
Switch
Shield (ground)
Signal4 ... 20 mA, 2-wireCable colour
UB+/S+ (CH1)1Brown
UB+/S+ (CH2)2White
0 V/S- (CH1)3Blue
0 V/S- (CH2)4Black
ShieldCase/Connector-
Signal4 ... 20 mA, 3-wireCable colour
UB+ (CH1+2)1Brown
0 V/S- (CH1+2)3Blue
S+ (CH1)4Black
S+ (CH2)2White
ShieldCase/Connector-
Signal0 ... 10 V, 3-wireCable colour
UB+ (CH1+2)1Brown
0 V/S- (CH1+2)3Blue
S+ (CH1)4Black
S+ (CH2)2White
ShieldCase/Connector-