AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
DMS-FP 1
DMS-FP
On order
WIKA · Pressure measurement · Family DMS

Diaphragm monitoring system with clamp connection

Diaphragm monitoring system with clamp connection for sanitary applications, combining diaphragm seal, pressure measuring instrument, and monitoring element for hygienic pressure measurement in pharmaceutical and food industries.
Range
-1…25 bar
Output
HART · PROFIBUS PA
Protection
IP65
3-A Sanitary StandardEHEDG3-AEHEDG Hygienic Equipment Design
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The WIKA combinations consisting of diaphragm seal, pressure measuring instrument and monitoring element are best suited for the harshest and hygienic measuring tasks. The systems can withstand the cleaning vapour temperatures occurring in SIP processes and ensure a sterile connection between the medium to be measured and the diaphragm seal.

The patented diaphragm monitoring has been designed specifically for the highest safety requirements in the pharmaceutical and biotechnology industries. The monitoring element is mainly used for electrical signal transmission of the diaphragm condition. In addition, the diaphragm condition is displayed on a dial with red/green areas.

In the event of a diaphragm rupture, a second, internal diaphragm in the pressure measuring instrument ensures the reliable separation of the environment and the process.

Special features

  • Double-diaphragm system to ensure the separation of the process and the pressure measuring instrument
  • Clamp connection easy to open for cleaning and seal replacement
  • Suitable for SIP and CIP
Identification
ModelDMS-FP
Product familyDMS
SubcategoryDiaphragm monitoring system
Measuring range
Pressure ranges0…2.5 bar · 0…4 bar · 0…6 bar · 0…10 bar · 0…16 bar · 0…25 bar · -1…1.6 bar · -1…3 bar · -1…5 bar · -1…10 bar · -1…15 bar · -1…25 bar
Process conditions
Process connection
Clamp connection per DIN 32676Clamp connection per ISO 2852
Process temperature+10…+130 °C
Electrical characteristics
Output signalHART · PROFIBUS PA · FOUNDATION Fieldbus · 4 ... 20 mA · 4...20mA with HART
Power supplyDC 12 ... 36 V
Electrical connectionCable bushing with 2 m cable
Switching functionSwitch point set to -0.2 bar rel. and rising pressure
Switching contacts1
Materials
Case materialStainless steel 1.4435 (316L), Stainless steel 316L, Stainless steel 316Ti, PBT, Aluminium die-casting, Stainless steel
Wetted parts materialStainless steel 1.4435 (316L), UNS S31603, Stainless steel 316L
Operating environment
Ambient temperature+10…+40 °C
IP ratingIP65
Certifications and approvals
Certifications
3-A Sanitary StandardEHEDG3-AEHEDG Hygienic Equipment Design
Additional details
Dial size63 mm
Datasheet languagesEN, DE
Tables from datasheet
Diaphragm seal system
VersionPressure measuring instrument mounted to a diaphragm seal with clamp connection, welded
Scale range Gauge pressure in bar [psi]0 ... 2.5 [0 ... 40] 0 ... 10 [0 ... 150]0 ... 4 [0 ... 60] 0 ... 16 [0 ... 250]0 ... 6 [0 ... 100] 0 ... 25 [0 ... 400]
Scale range 1) Vacuum in bar [psi]-1 ... 1.6 [-30 inHg ... 25] -1 ... 10 [-30 inHg ... 145]-1 ... 3 [-30 inHg ... 45] -1 ... 15 [-30 inHg ... 220]-1 ...+5 [-30 inHg ... +70] -1 ... 25 [-30 inHg ... 360]
Permissible temperature range Medium Ambient Storage+10 ...+80 °C [+50 ...+176 °F] for CIP and SIP max.+130 °C [+266 °F] +10 ...+40 °C [+50 ...+104 °F] +10 ...+60 °C [+50 ...+140 °F]
Ingress protection per IEC/EN 60529IP65
Material 2) wettedDiaphragm: Diaphragm seal: StainlessStainless steel 1.4435 (316L);UNS S31603 steel 1.4435 (316L);UNSS31603
Surface roughness wetted non-wettedRa ≤ 0.38 µm [15 µin] per ASME BPE SF4, electropolished [except for weld seam] Ra ≤ 0.76 µm [30 µin] [except for weld seam]
Mounting typeDirect mounting
Level of cleanliness of wetted partsOil and grease free per ASTM G93-03 level FWIKA standard (< 1,000 mg/m ² )
System fill fluidMedicinal white mineral oil KN 92 (FDA 21 CFR 172.878, 21 CFR 178.3620(a); USP, EP, JP)
Monitoring element 3)Switch contact and dial with red/green areas (contact pressure gauge, model PGS23.063)Dial with red/green areas (Bourdon tube pressure gauge, model 232.30.063)
Dial displayPointer in green range Pointer in red range→Outer diaphragm intact →Outer diaphragm defective
Nominal size63 [2.5"]
Material
Case Pressure element Movement Bayonet ringStainless steel, with solid baffle wall (Solidfront) and blow-out back Stainless steel 316L Stainless steel Stainless steel
Switch behaviourSwitch point set to -0.2 bar rel. and Switch point not reached →Outer Switch point reached →Outerrising pressure diaphragm intact diaphragm defectiveWithout
Switch contactReed switch model 851 No control unit and no power supply required Direct switching up to 150 V, 0.5 A Also suitable for direct triggering of a programmable logic con troller (PLC) Free from wear aswithout contactWithout
Electrical connectionCable bushing with 2 mcable (optional connectors availableon request)Without
Ingress protection per IEC/EN 60529IP65IP54
Model UPT-20
Output signal4 ...20mA
Load in Ω≤ (U+ - U min ) / 0.023 A
Power supplyDC 12 ...36V
Accuracy specifications0.10 %of span
Material Case SensorStainless steel 316Ti, electropolished or plastic (PBT) Stainless steel 316L
Model IPT-20
Output signal4 ...20mA 4 ... 20 mAwith a superimposed HART ® communication signal (option: SIL qualification) HART ® specification: 7.3 FOUNDATION TM Fieldbus PROFIBUS ® PA
Load in Ω(U B - U Bmin ) / 0.022 A U B = Applied power supply U Bmin = Minimum power supply
Accuracy at room temperature 1)Measuring ranges < 40 bar: ≤ 0.1 %of span
Material Case SensorDouble chamber case, aluminium die-casting AlSi10Mg, powder-coated on PE basis Stainless steel 316L
View all (14)
Model CPG1500
Accuracy 1)0.1%FS
Display5 ½-digit 7-segment display (incl. a large matrix area for auxiliary information) Bar graph, 0 ...100% Selectable backlighting
Rotatable caseThe case is rotatable by 330°.
Resolution4 ... 5 ½digits; adjustable
Voltage supply
Power supply3 x 1.5V AA alkaline batteries 2)
Maximum voltageDC 4.95V (sparking)
Battery lifetypical 2,000 ... 2,500 h (without backlighting and WIKA-Wireless not active)
Battery status displaySymbol display with 4 bars indicates the battery status in 25 %steps
Material
CaseAluminium die-casting, nickel-plated
SensorStainless steel 316
Model 23x.50,100
Nominal size100 [4.0"]
Ingress protection per IEC/EN 60529IP65
Pressure limitationSteady: 3/4 x full scale Fluctuating: 2/3 x full scale Short time: Full scale value
Material
CaseStainless steel, with solid baffle wall (Solidfront) and blow-out back, scale ranges ≤ 0 ... 16 bar (lower mount) with compensating valve to vent case
Pressure elementStainless steel 316L
MovementStainless steel 316L
DialAluminium, white, black lettering
Aluminium, black
Pointer
Laminated
safety
Window
glass
DNFor pipe Outer Ø x wall thicknessPN 1)DD1ID 2)MbA 3)
1½ "38.1 x 1.65 [1.5 x 0.065]4050.5 [1.988]58 [2.283]35.3 [1.39]29 [1.142]67 [2.638]
2 "50.8 x 1.65 [2 x 0.065]64 [2.52]68 [2.677]48 [1.89]38 [1.496]72 [2.835]
DNFor pipe Outer Ø x wall thicknessPN 1)DD1ID 2)MbA 3)
1½ "42.4 x 2 [1.67 x 0.079]4050.5 [1.988]58 [2.283]35.3 [1.39]29 [1.142]67 [2.638]
2 "48.3 x 2 [1.901 x 0.079]64 [2.52]68 [2.677]48 [1.89]38 [1.496]72 [2.835]
DNFor pipe Outer Ø x wall thicknessPN 1)DD1ID 2)MbA 3)
1½ "38.1 x 1.6 [1.5 x 0.062]4050.5 [1.988]58 [2.283]35.3 [1.39]29 [1.142]67 [2.638]
2 "50.8 x 1.6 [2 x 0.062]64 [2.52]68 [2.677]48 [1.89]38 [1.496]72 [2.835]
DNFor pipe Outer Ø x wall thicknessPN 1)DD1ID 2)MbA 3)
4041 x 1.5 [1.614 x 0.06]4050.5 [1.988]58 [2.283]38.2 [1.504]29 [1.142]67 [2.638]
5053 x 1.5 [2.087 x 0.06]64 [2.52]68 [2.677]50.2 [1.976]38 [1.496]72 [2.835]
DNFor pipe Outer Ø x wall thicknessPN 1)DD1ID 2)MbA 3)
3838 x 1.2 [1.5 x 0.047]4050.5 [1.988]58 [2.283]38.2 [1.504]29 [1.142]67 [2.638]
4040 x 1.2 [1.745 x 0.047]
5051 x 1.2 [2.008 x 0.047]64 [2.52]68 [2.677]50.2 [1.976]38 [1.496]72 [2.835]
LogoDescriptionCountry
®3-A Sanitary Standard These instruments are optionally 3-A marked based on a third party verification for conformance to the 3-A standard number 74.USA
FEBRUARY 2021 TYPE EL CLASS IEHEDG Hygienic Equipment DesignEuropean Community
ModelDescription
CPG-KITPPneumatic service kit, accuracy 0.1 %FS(0.05 %FSor 0.025 %FSalso available) ■ Model CPG1500 precision digital pressure gauge ■ Model CPP30 pneumatic hand test pump, pressure generation -0.95 ...+35 bar ■ Adapter set ■ Service case →See data sheet CT 93.01
CPH7000Portable process calibrator, accuracy 0.025%FS ■ Model CPH7000 process calibrator, integrated manual pressure generation -0.85 ...+25 bar ■ Power supply unit ■ Service case →See data sheet CT 15.51
DescriptionOrder number
Calibration adapter TRI-CLAMP ® , 1 ½"11563206
Calibration adapter TRI-CLAMP ® , 2"14332415