AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
611.10 1
611.10
In stock at WIKA
WIKA · Pressure measurement · Family 611

Capsule pressure gauge, copper alloy or stainless steel

Standard version, NS 50 [2"], 63 [2 ½"]
Range
-600…600 mbar
Accuracy
1.6
Protection
IP32
RoHSUKCAPressure Equipment Directive
Price
From €84
Confirm at order time
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The model 611.10 and 631.10 capsule pressure gauges are based upon the proven capsule measuring system. The capsule element measurement principle is suitable for very low pressures. On pressurisation, the expansion of the capsule element, proportional to the incident pressure, is transmitted to the movement and indicated.

The modular design enables a multitude of combinations of case materials, process connections, nominal sizes and scale ranges. Due to this high variance, the instrument is suitable for use in a wide range of applications within industry.

For further approvals, see page 7

Special features

  • Zero point setting in front
  • Special connection location on request
  • Low scale ranges from 0 ... 25 mbar to 0 ... 600 mbar or 0 ... 10 inH 2 O to 0 ... 240 inH 2 O
Identification
Model611.10
Product family611
SubcategoryCapsule pressure gauge
Measuring range
Pressure ranges0…25 mbar · 0…40 mbar · 0…60 mbar · 0…100 mbar · 0…160 mbar · 0…250 mbar · 0…400 mbar · 0…600 mbar · -600…0 mbar · -400…0 mbar · -250…0 mbar · -160…0 mbar · -100…0 mbar · -60…0 mbar · -40…0 mbar · -25…0 mbar · -12.5…12.5 mbar · -20…20 mbar · -30…30 mbar · -50…50 mbar · -80…80 mbar · -125…125 mbar · -200…200 mbar · -300…300 mbar
Accuracy
Accuracy class1.6
Accuracy standardEN 837-3
Process conditions
Process connection
G 1/8 BG 1/4 BM12 x 1.5R 1/41/8 NPT1/4 NPT
Process temperature−20…+100 °C
Materials
Case materialSteel, black
Wetted parts materialCopper alloy
Sealing materialNBR
Operating environment
Ambient temperature−20…+60 °C
IP ratingIP32
Weight0.09 kg
Certifications and approvals
Certifications
RoHSUKCAPressure Equipment Directive
Additional details
Dial size50 mm
Tables from datasheet
Basic information
StandardEN 837-3
→ For information on the 'Selection, installation, handling and operation of pressure gauges', see technical information IN 00.05
Further version■ Oil- and grease-free ■ For oxygen, oil- and grease-free
Nominal size (NS)■ Ø50 mm[2"] (only for model 611.10) ■ Ø63 mm[2 ½"]
Connection location■ Lower mount (radial) (only for NS 63 [2 ½"]) ■ Centre back mount
WindowPolycarbonate
Case■ Steel, black ■ Stainless steel (only for NS 63 [2 ½"])
Mounting■ Without ■ Surface mounting flange, steel, black (only for NS 63 [2 ½"]) ■ Panel mounting flange, steel, black, screwed ■ Panel mounting flange, steel, chrome-plated, screwed ■ Slip-on bezel, steel, black, pressed on ■ Slip-on bezel, stainless steel, pressed on ■ Slip-on bezel, polished stainless steel, pressed on ■ Triangular profile ring with mounting bracket, steel, black 1) ■ Triangular profile ring with mounting bracket, polished stainless steel 1) → For information on 'Mounting types, mounting flanges, panel cutouts',
see technical information IN 00.04
Movement■ Copper alloy ■ Stainless steel (only selectable for NS 63 [2 ½"])
Measuring element
Type of measuring elementCapsule element
Material (wetted)
Capsule elementModel 611.10Copper alloy
Model 631.10Stainless steel 316L
SealModel 611.10NBR
Model 631.10FKM
Process connectionModel 611.10Copper alloy
Model 631.10Stainless steel 316L
Leak tightness■ Leakage rate: < 1∙10 -3 mbar l/s
Accuracy specifications
Accuracy class
EN 837-3■ Class 1.6
ASME B40.100■ ±2 %│±1%│±2%ofmeasuring span (grade A)
Zero point setting with adjustment screw■ In front, after opening the window 1) ■ In front, through the opening in the window 2)
Temperature errorOn deviation from the reference conditions at the measuring system: ≤ ±0.6 %per 10 °C [≤ ±0.6 %per 18 °F] of full scale value
Reference conditions
Ambient temperature+20 °C [+68 °F]
mbar
0 ... 25 1)0 ... 160
0 ... 40 1)0 ... 250
0 ... 600 ... 400
0 ... 1000 ... 600
View all (20)
kPa
0 ... 2.5 1)0 ... 16
0 ... 4 1)0 ... 25
0 ... 60 ... 40
0 ... 100 ... 60
psi
0 ... 0.36 1)0 ... 2.5
0 ... 0.6 1)0 ... 3.6
0 ... 1.00 ... 6.0
0 ... 1.50 ... 10
inH 2 O
0 ...10 1)0 ... 60
0 ... 16 1)0 ... 100
0 ... 240 ... 160
0 ... 400 ... 240
kg/cm 2
0 ... 0.025 1)0 ... 0.16
0 ... 0.04 1)0 ... 0.25
0 ... 0.060 ... 0.4
0 ... 0.10 ... 0.6
Pa
0 ... 2,500 1)0 ... 16,000
0 ... 4,000 1)0 ... 25,000
0 ... 6,0000 ... 40,000
0 ... 10,0000 ... 60,000
mmH 2 O
0 ... 250 1)0 ... 1,600
0 ... 400 1)0 ... 2,500
0 ... 6000 ... 4,000
0 ... 1,0000 ... 6,000
oz/in 2
0 ... 6 1)0 ... 40
0 ... 10 1)0 ... 60
0 ... 150 ... 100
0 ... 250 ... 150
mbar
-25…0 1)-12.5 ... +12.5 1)
-40…0 1)-20 ...+20 1)
-60…0-30 ...+30
-100…0-50 ...+50
-160…0-80 ...+80
-250…0-125 ...+125
-400…0-200 ...+200
-600 ... 0-300 ...+300
kPa
-2.5…0 1)-1.25 ... +1.25 1)
-4…0 1)-2 ...+2 1)
-6…0-3 ...+3
-10…0-5 ...+5
-16…0-8 ...+8
-25…0-12.5 ... +12.5
-40…0-20 ...+20
-60 ... 0-30 ...+30
psi
-0.36 ... 0 1)-0.18 ... +0.18 1)
-0.6 ... 0 1)-0.3 ... +0.3 1)
-1 ... 0-0.5 ... +0.5
-1.5 ... 0-0.75 ... +0.75
-2.5 ... 0-1.25 ... +1.25
-3.6 ... 0-1.8 ... +1.8
-6 ... 0-3 ...+3
-10 ... 0-5 ...+5
inH 2 O
-10 ... 0 1)-5 ...+5 1)
-16 ... 0 1)-8 ...+8 1)
-24 ... 0-12 …+12
-40 ... 0-20 ...+20
-60 ... 0-30 ...+30
-100 ... 0-50 ...+50
-160 ... 0-80 ...+80
-240 ... 0-120 ...+120
kg/cm 21)
-0.025…0 1)-0.0125 ... +0.0125
-0.06…0-0.03 ... +0.03
-0.05 ... +0.05
-0.1…0 -0.16…0-0.08 ... +0.08
-0.25…0-0.125 ... +0.125
-0.4…0-0.2 ... +0.2
-0.6 ... 0-0.3 ... +0.3
Pa
-2,500…0 1)-1,250 ... +1,250 1)
-4,000…0 1)-2,000 ... +2,000 1)
-6,000…0-3,000 ... +3,000
-10,000…0-5,000 ... +5,000
-16,000…0-8,000 ... +8,000
-25,000…0-12,500 ... +12,500
-40,000…0-20,000 ... +20,000
-60,000 ... 0-30,000 ... +30,000
mmH 2 O
-250...0 1)-125 ...+125 1)
-400 ... 0 1)-200 ...+200 1)
-600 ... 0-300 ...+300
-1,000 ... 0-500 ...+500
-1,600 ... 0-800 ...+800
-2,500 ... 0-1,250 ... +1,250
-4,000 ... 0-2,000 ... +2,000
-6,000 ... 0-3,000 ...+3000
oz/in 2
-6…0-3 ...+3
-10…0-5 ...+5
-15…0-7.5 ... +7.5
-25…0-12.5 ... +12.5
-40…0-20 ...+20
-60…0-30 ...+30
-100…0-50 ...+50
-150…0-75 ...+75
Operating conditions
Medium temperature-20 ...+100 °C [-4 ...+212 °F]
Ambient temperature-20 ...+60 °C [-4 ...+140 °F]
Pressure limitation
SteadyFull scale value
Fluctuating0.9 x full scale value
Short time1.3 x full scale value
Ingress protection per IEC/EN 60529■ IP32 ■ IP54