The ZA 724 central interface module is the intelligent processor module of the HS 724i heater control.
Особенности
- Connection facility for max. sixteen LA 724i/LA 724i HP/LA 724i SSR power output modules per ZA 724 central interface module
- Communication via PROFIBUS DP interface
Дизайн
- Module encapsulated in metal enclosure
- Two LEDs for normal operation (green) and fault (red)
- PROFIBUS DP interface (up to 12 Mbit/s)
- Rotary switch for setting the PROFIBUS DP address
- RS 232 C serial interface
- Parallel bus interface to the power outputs
- Expansion slot for NE 724 power supply measuring module (option)
Функции
Communication
PROFIBUS DP
- Importing of parameter settings from host controller
- Transfer of diagnostics information to host controller
Parallel bus (internal)
- Control and monitoring of max. 384 power channels
Performance features
- Calculation of heat emitter values of power output channels
- Setpoints adjustable from 0% to 100% in steps of 0.5%
- Uniform distribution of load over all channels and all HS 724i heat controls used in the group
- Simple adaptation to the respective production process by selection of up to 4 operating modes
- Mixed operation of the various power outputs is possible
Diagnostics
- Evaluation of diagnostics information from connected power output modules
- Phase-sequence detection indicating whether phases L1, L2 and L3 are correctly connected
- Automatic detection of mains frequency
Mains synchronization
To ensure synchronization between the power outputs and the connected power supply, phase L1 is used for synchronization. The respective switch-on times for phases L2 and L3 are subsequently calculated automatically.
Технические данные [PDF]
.
Для просмотра информации в формате PDF необходимо установить Adobe Acrobat Reader.

Технические данные
| ZA 724 central interface module | |
|---|---|
| Rated voltage | 230 V AC |
| - Permissible range | 187 V AC ... 264 V AC |
| Rated frequency | 50 Hz/60 Hz |
| - Permissible range | |
| Non-periodic overvoltage(to EN 60204, Part 1) | |
| - Limit | 2 x Urated |
| - Duration | 1.5 ms (single pulse) |
| - Rise/fall time | 500 ns ... 500 ms |
| Brief voltage interruption(initial state: lower limit of rated voltage = 187 V) | |
| - Interruption time, max. | 20 ms |
| - Recovery time, min. | 1 s |
| - Events per hour, max. | 10 |
| Power consumption | |
| - Typical | 35 W |
| - Maximum | 46 W |
| Dimensions (W x H x D) | 50 mm x 480 mm x 210 mm |
| Weight, approx. | 4.2 kg |
Дальнейшая информация
| Ordering location | ||
|---|---|---|
| New parts and accessories | Siemens AG A&D SE FTH | Org-ID 10001539 |
| Repairs | Siemens AG A&D SE EWF RC Fürth | Org-ID AV000085 |
| Returned items | Siemens AG A&D RC Service | Org-ID A4025956 |
Заказные данные
| Заказной № | Описание | Вес (кг) | Доставка | Мин. зак. (шт) |
|---|---|---|---|---|
| 6BK1700-2BA30-0AA0 | ZA 724I ЦЕНТРАЛЬНЫЙ БЛОК ПОДКЛЮЧЕНИЯ ПОДКЛ. НА PROFIBUS-DP 12MБОД ТРЕБУЮТСЯ ДЛЯ РАБОТЫ СИЛОВЫЕ ВЫХОДЫ LA 724I, LA724IHP ИЛИ LA 724ISSR | 5.6 | 6 - 8 недель (C) | 1 |
Аксессуары
| Заказной № | Описание | Вес (кг) | Доставка | Мин. зак. (шт) |
|---|---|---|---|---|
| 6ES7171-1XX00-5AA0 | ЛЕНТОЧНЫЙ КАБЕЛЬ ДЛЯ СИСТЕМЫ УПРАВЛЕНИЯ НАГРЕВОМ ДЛЯ ПОДКЛЮЧЕНИЯ ВТОРОЙ ЛИНЕЙКИ | 0.076 | 6 - 8 недель (C) | 1 |
| 6ES7171-2XX00-6DA0 | УПРАВЛЕНИЕ НАГРЕВОМ-ТОКОВЫЕ ШИНЫ КАК ЗАП. ЧАСТЬ | 0.022 | 6 - 8 недель (C) | 1 |
Аксессуары [PDF]
.
Для просмотра информации в формате PDF необходимо установить Adobe Acrobat Reader.