SITRANS FUS1010 is the most versatile clamp-on ultrasonic flowmeter available today. It can operate in either WideBeam Transit-Time or Reflexor (Doppler) mode, making it suitable for virtually any liquid, even those with high aeration or suspended solids.
SITRANS FUS1010 is available in single or dual channel, dual path configuration. Optional four channel, 4 path configurations, with your choice of IP65 (NEMA 4X), IP65 (NEMA 7) and IP66 (NEMA 7) explosion proof enclosures.
Особенности
- Versatility; there is no need to change meters when operating conditions change
- Easy installation; no need to cut pipe or stop flow
- Minimal maintenance; external transducers do not require periodic cleaning
- No moving parts to foul or wear
- No pressure drop or energy loss
- Wide turn-down ratio
- Choice of single channel or dual channel/dual path, with doppler capability. Four channel/four beam optional.
- Optional four channels allow measurement of four independent pipes at the same time, reducing overall ownership costs
- Dual mode allows for transit time and reflexor operation at the same time on the same pipe
- Dual path allows for two sets of transducers to be set up on one pipe and averaged for higher accuracy
- Wide-Beam technology automatically adjusts meter settings to the specific application upon installation for exceptional accuracy and extended applicability range
- Zeromatic Path automatically sets zero without stopping flow and reduces zero drift, even at low flow
Область применения
FUS1010 is suitable for a wide variety of liquid applications, including the following:
- Water industry Raw water Potable water Sludges Chemicals
- Wastewater industry Raw sewage Effluent Sludges Mixed liquor Chemicals
- HVAC industry Chillers Condensers Hot and cold water systems
- Power industry Nuclear Fossil Hydroelectric
- Processing industry Process control Batching Rate indication Volumetric and mass measurement
Дизайн
FUS1010 is available in three configurations:
- IP65 (NEMA 4X) enclosure
- Single channel
- Dual channel / dual path
- Four channel (optional)
- IP65 (NEMA 7) Compact explosion proof enclosure
- Single channel
- Dual channel / dual path
- IP66 (NEMA 7) Wall mount explosion proof enclosure
- Single channel
- Dual channel / dual path
- Four channel (optional)
Функции
- IP65 (NEMA 4X) and IP66 (NEMA 7) flow display computers have integral 33 button keypads and large (128 x 240 pixel) graphic displays visible up to 12 m (40 ft) away
- IP65 (NEMA 7) compact flow display computer has a 2 x 16 Alphanumeric LCD display
- Current, voltage, status alarm, frequency and RS232 outputs (see specification section for details)
- Optional current, voltage and temperature inputs (see specification section for details)
- Zeromatic Path automatically sets zero
- Bidirectional flow operation
- 1 MByte data logger with both site and data logger storage
- English, Spanish, German, Italian and French language options
Технические данные
SITRANS FUS1010, IP65 (NEMA 4X) Flow display computer
| Enclosure IP65 (NEMA 4X) | |
|---|---|
| Input | |
| Flow range | ± 12 m/s (± 40 ft/s), bidirectional |
| Pipe size | 6.4 mm ... 9.14 m (0.25“ ... 360“) |
| Optional inputssingle channel | - Current: 2x 4 … 20 mA DC - Voltage: 2x 0 … 10 V DC - Temperature: 2x 4 wire 1 kW RTD |
| Output | |
| Outputs single channel | - Current: 2x 4 … 20 mA DC (1 kW at 30 V DC) - Voltage: 2x 0 … 10 V DC (5 kW min.) - Status Alarm: 4x SPDT relays - Frequency: 2x 0 … 5 kHz - RS232 |
| Accuracy | |
| Accuracy | ± 0.5% ... 1.0% of flow,for velocities greater than 0.3 m/s (1 ft/s)± 0.0015 ... 0.003 m/s (± 0.005 ... 0.01 ft/s),for velocities less than 0.3 m/s (1 ft/s) |
| Batch repeatability | ± 0.15% of flow,for velocities greater than 0.3 m/s (1 ft/s)± 0.0005 m/s (± 0.0015 ft/s),for velocities less than 0.3 m/s (1 ft/s) |
| Data refresh rate | 5 Hz |
| Rated operation conditions | |
| Degree of protection | IP65 (NEMA 4X) |
| Liquid temperature | |
| - Standard | -40 ... +120 °C (-40 ... +250 °F) |
| - Option | -40 ... +230 °C (-40 ... +450 °F) |
| Ambient temperature | -18 … +60 °C (0 … +140 °F) |
| Design | |
| Dimensions | see SITRANS F US Clamp-on “System info and selsction guide” |
| Weight | see diagrams |
| Power supply | 90 ... 240 V AC, 50 ... 60 Hz., 30 VA or9 ... 36 V DC, 12 W |
| Indication and operation | |
| Data logger memory | 1 MByte |
| Display | 128 x 240 pixel LCD with backlight |
| Keypad | 33 keypad buttons with tactile feedback |
| Language options | English, Spanish, German, Italian, French |
| Certificates and approvals | |
| FM and CSA ratings | I.S. Class 1, 2, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only) |
| ATEX ratings | |
| - Flow display computer | Ex II (1) G [EEx ia] IICEx II 3 (1) G EEx nC [ia] IIC T5 |
| - Transducers | Ex II 1 G EEx ia IIC T5Ex II 2 G EEx m II T5(for use with flowmeter in safe area) |
| CCOE rating | EEx (ia) |
| CEPEL ratings | |
| - Flow display computer | [BR-Ex ia] IIC T6 (pending on 4 channel)BR-Ex nC [ia] IIC T6 (pending) |
| - Transducers | BR-Ex ia IIC T6 IP65 |
| GoST ratings | |
| - Flow display computer | [Exia]IIC |
| - Transducers | [Exia]IICT5 |
SITRANS FUS1010S, IP65 (NEMA 7) Compact explosion proof
| Enclosure IP65 (NEMA 7) | |
|---|---|
| Input | |
| Flow range | ± 12 m/s (± 40 ft/s), bidirectional |
| Pipe size | 6.4 mm... 9.14 m (0.25” ... 360”) |
| Optional inputssingle channel | - Current: 1x 4 … 20 mA DC - Temperature: 2x 4 wire 1 kΩ RTD |
| Output | |
| Outputssingle channel | - Current (externally powered): 1x 4 … 20 mA DC(1 kΩ at 30 V DC) - Status Alarm: 1x Isolated open collector - Frequency: 2x 0 … 5 kHz - RS232 |
| Accuracy | |
| Calibratable accuracy | 0.1% (API proving method) |
| Intrinsic accuracy | ± 0.5% ... 1.0% of flow,for velocities greater than 0.3 m/s (1 ft/s)± 0.0015 ... 0.003 m/s (± 0.005 ... 0.01 ft/s),for velocities less than 0.3 m/s (1 ft/s) |
| Batch repeatability | ± 0.15% of flow,for velocities greater than 0.3 m/s (1 ft/s)± 0.0005 m/s (± 0.0015 ft/s),for velocities less than 0.3 m/s (1 ft/s) |
| Data refresh rate | 5 Hz |
| Rated operation conditions | |
| Degree of protection | IP65 (NEMA 7) |
| Liquid temperature | |
| - Standard | -40 ... +120 °C (-40 ... +250 °F) |
| - Optional | -40 ... 230 °C (-40 ... +450 °F) |
| Ambient temperature | -18 … +60 °C (0 … +140 °F) |
| Design | |
| Dimensions | see SITRANS F US Clamp-on “System info and selsction guide” |
| Weight | see diagrams |
| Power supply | 90 ... 240 V AC, 50 ... 60 Hz., 15 VA or9 ... 36 V DC, 10 W |
| Indication and operation | |
| Data logger memory | 1 MByte |
| Display | 2 x 16 alphanumeric LCD display |
| Keypad | 5 Magnetic hall effect switches |
| Language options | English, Spanish, German, Italian, French |
| Certificates and approvals | |
| FM and CSA ratings | Ex Class 1, Div 1D-I Class 2, Div 1I.S. Class 1, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only) |
| ATEX ratings | |
| - Flow display computer | Ex II 2 (1) G EEx d [ia] IIC T5 |
| - Transducers | Ex II 1 G EEx ia IIC T5 |
| CCOE rating | EEx d |
| CEPEL ratings | |
| - Flow display computer | BR-Ex d [ia] IIC T6 |
| - Transducers | BR-Ex ia IIC T6 IP65 |
SITRANS FUS1010S, IP66 (NEMA 7) Wall mount explosion proof enclosure
| Enclosure IP66 (NEMA 7) | |
|---|---|
| Input | |
| Flow range | ± 12 m/s (± 40 ft/s), bidirectional |
| Pipe size | 6.4 mm... 9.14 m (0.25” ... 360”) |
| Optional Inputssingle channel | - Current: 2x 4 … 20 m ADC - Voltage: 2x 0 … 10 V DC - Temperature: 2x 4 wire 1 k Ω RTD |
| Output | |
| Outputssingle channel | - Current: 2x 4 … 20 mA DC (1 k Ω at 30 V DC) - Voltage: 2x 0 … 10 V DC (5 kΩ min.) - Status Alarm: 4x SPDT Relays - Frequency: 2x 0 … 5 kHz - RS232 |
| Accuracy | |
| Accuracy | ± 0.5% ... 1.0% of flow,for velocities greater than 0.3 m/s (1 ft/s)± 0.0015 ... 0.003 m/s (± 0.005 ... 0.01 ft/s),for velocities less than 0.3 m/s (1 ft/s) |
| Batch repeatability | ± 0.15% of flow,for velocities greater than 0.3 m/s (1 ft/s)± 0.0005 m/s (± 0.0015 ft/s),for velocities less than 0.3 m/s (1 ft/s) |
| Data refresh rate | 5 Hz |
| Rated operation conditions | |
| Degree of protection | IP66 (NEMA 7) |
| Liquid temperature | |
| - Standard | -40 ... +120 °C (-40 ... +250 °F) |
| - Optional | -40 ... 230 °C (-40 ... 450 °F) |
| Ambient temperature | -18 … +60 °C (0 … 140 °F) |
| Design | |
| Dimensions | see SITRANS F US Clamp-on “System info and selsction guide” |
| Weight | see diagrams |
| Power supply | 90 ... 240 V AC, 50 ... 60 Hz., 30 VA or9 ... 36 V DC, 12 W |
| Indication and operation | |
| Data logger memory | 1 MByte |
| Display | 128 x 240 pixel LCD with backlight |
| Keypad | 33 keypad buttons with tactile feedback |
| Language options | English, Spanish, German, Italian, French |
| Certificates and approvals | |
| FM and CSA ratings | Ex Class 1, Div 1D-I Class 2, Div 1I.S. Class 1, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only) |
| ATEX ratings | |
| - Flow display computer | Ex II (1) G [EEx ia] IICEx II 3 (1) G EEx nC [ia] IIC T5Ex II 2 (1) G EEx d [ia IIC] IIB T5Ex II 2 (1) G EEx d [ia IIC] IIB + H2 T5 |
| - Transducers | Ex II 1 G EEx ia IIC T5 |
| CEPEL ratings | |
| - Flow display computer | [BR-Ex ia] IIC T6 (pending)BR-Ex nC [ia] IIC T6 (pending)BR-Ex d [ia] IIC T6 (pending) |
| - Transducers | BR-Ex ia IIC T6 IP65 |
Transducer selection charts
| Universal transducers for any pipe material | |||||
|---|---|---|---|---|---|
| Transducer Size Code | Order Code | Outer diameter range (mm) | Outer diameter range (inches) | ||
| min | max | min | max | ||
| A2 | B | 12.7 | 50.8 | 0.5 | 2 |
| B3 | C | 19 | 127 | 0.75 | 5 |
| C3 | D | 51 | 305 | 2 | 12 |
| D3 | E | 203 | 610 | 8 | 24 |
| E2 | F | 254 | 6096 | 10 | 240 |
| High precision transducers for steel pipe with outer diameter/wall thickness ratio > 10 | |||||
|---|---|---|---|---|---|
| Transducer | Order Code | Pipe wall (mm) | Pipe wall (inches) | ||
| Size Code | min | max | min | max | |
| A1H | G | 0.635 | 1.016 | 0.025 | 0.04 |
| A2H | H | 1.016 | 1.524 | 0.04 | 0.06 |
| A3H | J | 1.524 | 2.032 | 0.06 | 0.08 |
| B1H | K | 2.032 | 3.048 | 0.08 | 0.12 |
| B2H | L | 3.048 | 4.064 | 0.12 | 0.16 |
| C1H | M | 4.064 | 5.842 | 0.16 | 0.23 |
| C2H | N | 5.842 | 8.128 | 0.23 | 0.32 |
| D1H | P | 8.128 | 11.176 | 0.32 | 0.44 |
| D2H | Q | 11.176 | 15.748 | 0.44 | 0.62 |
| D4H | R | 15.748 | 31.75 | 0.62 | 1.25 |
Transducer cable selection chart
| Transducer cable codes for length and type options | ||||
|---|---|---|---|---|
| Cable length m (ft) | Standard (PVCjacket)-40 … +80 °C(-40 … +176 °F) | Submersible(polyethylene jacket)-40 … +80 °C(-40 … +176 °F) | Plenum Rated(teflon jacket)-40 … +200 °C(-40 … +392 °F) | Armored-40 … +80 °C(-40 … +176 °F) |
| Order code | ||||
| 6 (20) | K01 | K11 | K21 | K31 |
| 15 (50) | K02 | K12 | K22 | K32 |
| 30 (100) | K03 | K13 | K23 | K33 |
| 46 (150) | K04 | K14 | K24 | K34 |
| 61 (200) | K05 | K15 | K25 | K35 |
| 91 (300) | K06 | K16 | K26 | K36 |
RTD cable selection chart
| RTD cable codes for length and type | ||
|---|---|---|
| Cable length m (ft) | Standard (teflon wrapped) -40 ... +200 °C(-40 … +392 °F) | Submersible (extruded jacket) -40 ... +200 °C(-40 … +392 °F) |
| Order code | ||
| 6 (20) | R01 | R11 |
| 15 (50) | R02 | R12 |
| 30 (100) | R03 | R13 |
| 46 (150) | R04 | R14 |
| 61 (200) | R05 | R15 |
| 91 (300) | R06 | R16 |
Заказные данные
| Заказной № | Описание | Вес (кг) | Доставка | Мин. зак. (шт) |
|---|---|---|---|---|
| 7ME3530-.....-.... | SITRANS FUS1010 STANDARD CLAMP-ON, IP65 (NEMA 4X) | 4.1 | по запросу (D) | 1 |
| 7ME3531-.....-.... | SITRANS FUS1010 STANDARD CLAMP-ON, IP65 (NEMA 7), COMPACT | 4.4 | по запросу (X) | 1 |
| 7ME3532-.....-.... | SITRANS FUS1010 STANDARD CLAMP-ON, IP66 (NEMA 7), WALL MOUNTED | 29 | по запросу (X) | 1 |
| 7ME3533-.....-.... | SITRANS FUS1010 STANDARD CLAMP-ON, IP66 (NEMA 7), WALL MOUNTED, WITH DISPLAY WINDOW | 31.8 | по запросу (X) | 1 |