SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

SITRANS FUS1010 Standard clamp on

SITRANS FUS1010 is the most versatile clamp-on ultrasonic flowmeter available today. It can operate in either WideBeam Transit-Time or Reflexor (Doppler) mode, making it suitable for virtually any liquid, even those with high aeration or suspended solids.

SITRANS FUS1010 is available in single or dual channel, dual path configuration. Optional four channel, 4 path configurations, with your choice of IP65 (NEMA 4X), IP65 (NEMA 7) and IP66 (NEMA 7) explosion proof enclosures.

Особенности

  • Versatility; there is no need to change meters when operating conditions change
  • Easy installation; no need to cut pipe or stop flow
  • Minimal maintenance; external transducers do not require periodic cleaning
  • No moving parts to foul or wear
  • No pressure drop or energy loss
  • Wide turn-down ratio
  • Choice of single channel or dual channel/dual path, with doppler capability. Four channel/four beam optional.
  • Optional four channels allow measurement of four independent pipes at the same time, reducing overall ownership costs
  • Dual mode allows for transit time and reflexor operation at the same time on the same pipe
  • Dual path allows for two sets of transducers to be set up on one pipe and averaged for higher accuracy
  • Wide-Beam technology automatically adjusts meter settings to the specific application upon installation for exceptional accuracy and extended applicability range
  • Zeromatic Path automatically sets zero without stopping flow and reduces zero drift, even at low flow

Область применения

FUS1010 is suitable for a wide variety of liquid applications, including the following:

  • Water industry Raw water Potable water Sludges Chemicals
  • Wastewater industry Raw sewage Effluent Sludges Mixed liquor Chemicals
  • HVAC industry Chillers Condensers Hot and cold water systems
  • Power industry Nuclear Fossil Hydroelectric
  • Processing industry Process control Batching Rate indication Volumetric and mass measurement

Дизайн

FUS1010 is available in three configurations:

  • IP65 (NEMA 4X) enclosure
  • Single channel
  • Dual channel / dual path
  • Four channel (optional)
  • IP65 (NEMA 7) Compact explosion proof enclosure
  • Single channel
  • Dual channel / dual path
  • IP66 (NEMA 7) Wall mount explosion proof enclosure
  • Single channel
  • Dual channel / dual path
  • Four channel (optional)

Функции

  • IP65 (NEMA 4X) and IP66 (NEMA 7) flow display computers have integral 33 button keypads and large (128 x 240 pixel) graphic displays visible up to 12 m (40 ft) away
  • IP65 (NEMA 7) compact flow display computer has a 2 x 16 Alphanumeric LCD display
  • Current, voltage, status alarm, frequency and RS232 outputs (see specification section for details)
  • Optional current, voltage and temperature inputs (see specification section for details)
  • Zeromatic Path automatically sets zero
  • Bidirectional flow operation
  • 1 MByte data logger with both site and data logger storage
  • English, Spanish, German, Italian and French language options

Технические данные

SITRANS FUS1010, IP65 (NEMA 4X) Flow display computer

Enclosure IP65 (NEMA 4X)
Input
Flow range ± 12 m/s (± 40 ft/s), bidirectional
Pipe size 6.4 mm ... 9.14 m (0.25“ ... 360“)
Optional inputssingle channel - Current: 2x 4 … 20 mA DC - Voltage: 2x 0 … 10 V DC - Temperature: 2x 4 wire 1 kW RTD
Output
Outputs single channel - Current: 2x 4 … 20 mA DC (1 kW at 30 V DC) - Voltage: 2x 0 … 10 V DC (5 kW min.) - Status Alarm: 4x SPDT relays - Frequency: 2x 0 … 5 kHz - RS232
Accuracy
Accuracy ± 0.5% ... 1.0% of flow,for velocities greater than 0.3 m/s (1 ft/s)± 0.0015 ... 0.003 m/s (± 0.005 ... 0.01 ft/s),for velocities less than 0.3 m/s (1 ft/s)
Batch repeatability ± 0.15% of flow,for velocities greater than 0.3 m/s (1 ft/s)± 0.0005 m/s (± 0.0015 ft/s),for velocities less than 0.3 m/s (1 ft/s)
Data refresh rate 5 Hz
Rated operation conditions
Degree of protection IP65 (NEMA 4X)
Liquid temperature
- Standard -40 ... +120 °C (-40 ... +250 °F)
- Option -40 ... +230 °C (-40 ... +450 °F)
Ambient temperature -18 … +60 °C (0 … +140 °F)
Design
Dimensions see SITRANS F US Clamp-on “System info and selsction guide”
Weight see diagrams
Power supply 90 ... 240 V AC, 50 ... 60 Hz., 30 VA or9 ... 36 V DC, 12 W
Indication and operation
Data logger memory 1 MByte
Display 128 x 240 pixel LCD with backlight
Keypad 33 keypad buttons with tactile feedback
Language options English, Spanish, German, Italian, French
Certificates and approvals
FM and CSA ratings I.S. Class 1, 2, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only)
ATEX ratings
- Flow display computer Ex II (1) G [EEx ia] IICEx II 3 (1) G EEx nC [ia] IIC T5
- Transducers Ex II 1 G EEx ia IIC T5Ex II 2 G EEx m II T5(for use with flowmeter in safe area)
CCOE rating EEx (ia)
CEPEL ratings
- Flow display computer [BR-Ex ia] IIC T6 (pending on 4 channel)BR-Ex nC [ia] IIC T6 (pending)
- Transducers BR-Ex ia IIC T6 IP65
GoST ratings
- Flow display computer [Exia]IIC
- Transducers [Exia]IICT5

SITRANS FUS1010S, IP65 (NEMA 7) Compact explosion proof

Enclosure IP65 (NEMA 7)
Input
Flow range ± 12 m/s (± 40 ft/s), bidirectional
Pipe size 6.4 mm... 9.14 m (0.25” ... 360”)
Optional inputssingle channel - Current: 1x 4 … 20 mA DC - Temperature: 2x 4 wire 1 kΩ RTD
Output
Outputssingle channel - Current (externally powered): 1x 4 … 20 mA DC(1 kΩ at 30 V DC) - Status Alarm: 1x Isolated open collector - Frequency: 2x 0 … 5 kHz - RS232
Accuracy
Calibratable accuracy 0.1% (API proving method)
Intrinsic accuracy ± 0.5% ... 1.0% of flow,for velocities greater than 0.3 m/s (1 ft/s)± 0.0015 ... 0.003 m/s (± 0.005 ... 0.01 ft/s),for velocities less than 0.3 m/s (1 ft/s)
Batch repeatability ± 0.15% of flow,for velocities greater than 0.3 m/s (1 ft/s)± 0.0005 m/s (± 0.0015 ft/s),for velocities less than 0.3 m/s (1 ft/s)
Data refresh rate 5 Hz
Rated operation conditions
Degree of protection IP65 (NEMA 7)
Liquid temperature
- Standard -40 ... +120 °C (-40 ... +250 °F)
- Optional -40 ... 230 °C (-40 ... +450 °F)
Ambient temperature -18 … +60 °C (0 … +140 °F)
Design
Dimensions see SITRANS F US Clamp-on “System info and selsction guide”
Weight see diagrams
Power supply 90 ... 240 V AC, 50 ... 60 Hz., 15 VA or9 ... 36 V DC, 10 W
Indication and operation
Data logger memory 1 MByte
Display 2 x 16 alphanumeric LCD display
Keypad 5 Magnetic hall effect switches
Language options English, Spanish, German, Italian, French
Certificates and approvals
FM and CSA ratings Ex Class 1, Div 1D-I Class 2, Div 1I.S. Class 1, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only)
ATEX ratings
- Flow display computer Ex II 2 (1) G EEx d [ia] IIC T5
- Transducers Ex II 1 G EEx ia IIC T5
CCOE rating EEx d
CEPEL ratings
- Flow display computer BR-Ex d [ia] IIC T6
- Transducers BR-Ex ia IIC T6 IP65

SITRANS FUS1010S, IP66 (NEMA 7) Wall mount explosion proof enclosure

Enclosure IP66 (NEMA 7)
Input
Flow range ± 12 m/s (± 40 ft/s), bidirectional
Pipe size 6.4 mm... 9.14 m (0.25” ... 360”)
Optional Inputssingle channel - Current: 2x 4 … 20 m ADC - Voltage: 2x 0 … 10 V DC - Temperature: 2x 4 wire 1 k Ω RTD
Output
Outputssingle channel - Current: 2x 4 … 20 mA DC (1 k Ω at 30 V DC) - Voltage: 2x 0 … 10 V DC (5 kΩ min.) - Status Alarm: 4x SPDT Relays - Frequency: 2x 0 … 5 kHz - RS232
Accuracy
Accuracy ± 0.5% ... 1.0% of flow,for velocities greater than 0.3 m/s (1 ft/s)± 0.0015 ... 0.003 m/s (± 0.005 ... 0.01 ft/s),for velocities less than 0.3 m/s (1 ft/s)
Batch repeatability ± 0.15% of flow,for velocities greater than 0.3 m/s (1 ft/s)± 0.0005 m/s (± 0.0015 ft/s),for velocities less than 0.3 m/s (1 ft/s)
Data refresh rate 5 Hz
Rated operation conditions
Degree of protection IP66 (NEMA 7)
Liquid temperature
- Standard -40 ... +120 °C (-40 ... +250 °F)
- Optional -40 ... 230 °C (-40 ... 450 °F)
Ambient temperature -18 … +60 °C (0 … 140 °F)
Design
Dimensions see SITRANS F US Clamp-on “System info and selsction guide”
Weight see diagrams
Power supply 90 ... 240 V AC, 50 ... 60 Hz., 30 VA or9 ... 36 V DC, 12 W
Indication and operation
Data logger memory 1 MByte
Display 128 x 240 pixel LCD with backlight
Keypad 33 keypad buttons with tactile feedback
Language options English, Spanish, German, Italian, French
Certificates and approvals
FM and CSA ratings Ex Class 1, Div 1D-I Class 2, Div 1I.S. Class 1, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only)
ATEX ratings
- Flow display computer Ex II (1) G [EEx ia] IICEx II 3 (1) G EEx nC [ia] IIC T5Ex II 2 (1) G EEx d [ia IIC] IIB T5Ex II 2 (1) G EEx d [ia IIC] IIB + H2 T5
- Transducers Ex II 1 G EEx ia IIC T5
CEPEL ratings
- Flow display computer [BR-Ex ia] IIC T6 (pending)BR-Ex nC [ia] IIC T6 (pending)BR-Ex d [ia] IIC T6 (pending)
- Transducers BR-Ex ia IIC T6 IP65

Transducer selection charts

Universal transducers for any pipe material
Transducer Size Code Order Code Outer diameter range (mm) Outer diameter range (inches)
min max min max
A2 B 12.7 50.8 0.5 2
B3 C 19 127 0.75 5
C3 D 51 305 2 12
D3 E 203 610 8 24
E2 F 254 6096 10 240
High precision transducers for steel pipe with outer diameter/wall thickness ratio > 10
Transducer Order Code Pipe wall (mm) Pipe wall (inches)
Size Code min max min max
A1H G 0.635 1.016 0.025 0.04
A2H H 1.016 1.524 0.04 0.06
A3H J 1.524 2.032 0.06 0.08
B1H K 2.032 3.048 0.08 0.12
B2H L 3.048 4.064 0.12 0.16
C1H M 4.064 5.842 0.16 0.23
C2H N 5.842 8.128 0.23 0.32
D1H P 8.128 11.176 0.32 0.44
D2H Q 11.176 15.748 0.44 0.62
D4H R 15.748 31.75 0.62 1.25

Transducer cable selection chart

Transducer cable codes for length and type options
Cable length m (ft) Standard (PVCjacket)-40 … +80 °C(-40 … +176 °F) Submersible(polyethylene jacket)-40 … +80 °C(-40 … +176 °F) Plenum Rated(teflon jacket)-40 … +200 °C(-40 … +392 °F) Armored-40 … +80 °C(-40 … +176 °F)
Order code
6 (20) K01 K11 K21 K31
15 (50) K02 K12 K22 K32
30 (100) K03 K13 K23 K33
46 (150) K04 K14 K24 K34
61 (200) K05 K15 K25 K35
91 (300) K06 K16 K26 K36

RTD cable selection chart

RTD cable codes for length and type
Cable length m (ft) Standard (teflon wrapped) -40 ... +200 °C(-40 … +392 °F) Submersible (extruded jacket) -40 ... +200 °C(-40 … +392 °F)
Order code
6 (20) R01 R11
15 (50) R02 R12
30 (100) R03 R13
46 (150) R04 R14
61 (200) R05 R15
91 (300) R06 R16

Заказные данные

Заказной № Описание Вес (кг) Доставка Мин. зак. (шт)
7ME3530-.....-.... SITRANS FUS1010 STANDARD CLAMP-ON, IP65 (NEMA 4X) 4.1 по запросу (D) 1
7ME3531-.....-.... SITRANS FUS1010 STANDARD CLAMP-ON, IP65 (NEMA 7), COMPACT 4.4 по запросу (X) 1
7ME3532-.....-.... SITRANS FUS1010 STANDARD CLAMP-ON, IP66 (NEMA 7), WALL MOUNTED 29 по запросу (X) 1
7ME3533-.....-.... SITRANS FUS1010 STANDARD CLAMP-ON, IP66 (NEMA 7), WALL MOUNTED, WITH DISPLAY WINDOW 31.8 по запросу (X) 1