SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

SITRANS FUG1010 Gas meter clamp-on

SITRANS FUG1010 clamp-on non-intrusive ultrasonic flowmeter is ideal for natural and process gas applications, including checkmetering, allocation, production, storage and gas fired power station applications.

SITRANS FUG1010 is available in single, dual and optional four beam configurations, with your choice of IP65 (NEMA 4X) or IP65 (NEMA 7) and IP66 (NEMA 7) explosion proof enclosures.

Особенности

  • Easy installation; no need to cut pipe or stop flow
  • Minimal maintenance; external transducers do not require periodic cleaning
  • No moving parts to foul or wear as found in turbine and PD meters
  • Eliminates the pressure drop or energy loss in orifice metering
  • Wide turn-down ratio
  • Choice of single, dual or optional four beam versions
  • Single beam version reduces initial investment
  • Multiple beam versions provide higher accuracy, especially with limited straight run and poor flow profile conditions
  • In diametric reflect mode configuration, the meter is less sensitive to crossflow and swirl
  • Wide-Beam technology provides improved accuracy over a wide range of flow velocity and operating pressure
  • Zeromatic Path automatically sets zero without stopping flow and reduces zero drift, even at low flow
  • Tolerant of most wet gas conditions
  • Immune to most pressure reducing valve noise
  • Optional rugged stainless steel transducer enclosure permits permanent and direct burial installations
  • Easy to use “DataView” diagnostic software

Область применения

SITRANS FUG1010 is ideal for most natural and process gas industry applications, including:

  • Checkmetering
  • Allocation
  • Flow survey verification
  • Lost and unaccounted for (LAUF) gas analysis
  • Production
  • Storage

Дизайн

FUG1010 is available in three enclosures:

  • IP65 (NEMA 4X) enclosure
  • Single beam
  • Dual beam
  • Four beam (optional)
  • IP65 (NEMA 7) Compact explosion proof enclosure
  • Single beam
  • Dual beam
  • IP66 (NEMA 7) Wall mount explosion proof enclosure, waterproof
  • Single beam
  • Dual beam
  • Four beam (optional)

Функции

  • IP65 (NEMA 4X) and IP66 (NEMA 7) flow display computers have integral 33 button keypads and large (128 x 240 pixel) graphic displays visible up to 12 m (40 ft) away
  • IP65 (NEMA 7) compact flow display computer has a 2x 16 alphanumeric LCD display
  • Current, voltage, frequency and RS232 outputs (see specification section for details)
  • Analog inputs for pressure and temperature
  • Zeromatic Path automatically compensates for zero flow drift
  • Bidirectional flow operation
  • 1 Mbyte data logger with both site and data logger storage
  • English, Spanish, German, Italian and French language options
  • Internal AGA-8 table for fixed gas composition is available for standard volume computation
  • Complete application and operation diagnostics, to assure calibration and operational integrity
  • Upward compatibility and compliance with expected AGA-10 speed of sound measurement practice

Технические данные

SITRANS FUG1010
Input
Flow range ± 30 m/s (± 100 ft/s), bidirectional
Flow sensitivity 0.0003 m/s (0.001 ft/s), flow rate independent
Minimum pressure 7 … 10 bar (100 … 145 psi), typical (gas composition and application dependent; plastic pipes support operation at atmospheric pressure)
Pipe size 25 mm … 1.52 m (1”… 60“) (for other sizes, consult factory)
Analog inputs Current: 4x 4 … 20 mA, programmable(IP65 (NEMA 7) enclosure has (2x))
Output
Outputs - Current: 2x 4 … 20 m, a programmable, standardAdditional 2x optional, except IP65 (NEMA 7) - Voltage: 2x 0 … 10 V DC, menu programmable(None for IP65 (NEMA 7) enclosure) - 2x Open collector digital pulses (quadrature)(None for IP65 (NEMA 7) enclosure) - 2x 0 … 5 kHz, TTL pulse square wave +(None for IP65 (NEMA 7) enclosure) - 1x Optically isolated digital pulse & source, IP65 (NEMA 7) enclosure only - RS232 Serial Port
Optional outputs - MODBUS (RS485/422/232)(not for IP65 (NEMA 7) - Ethernet (not for IP66 (NEMA 7) - Telephone modem (not for IP66 (NEMA 7))
Status/Alarm I/O - 4x programmable form C relays(not for IP65 (NEMA 7) enclosure) - 4x programmable N.O. Mer. Wet. Relays optional (not for IP65 (NEMA 7) enclosure) - 2x Optically coupled output logic gates(for IP65 (NEMA 7) enclosure, only) - 1 Totalizer clear switch input(not for IP65 (NEMA 4X) enclosure, only) - 1 Totalizer hold switch input(not for IP65 (NEMA 7) enclosure) - 1x Opto iso. totalizer clear switch input(for IP65 (NEMA 7) enclosure, only) - 1x Opto iso. totalizer hold switch input(for IP 65 (NEMA 7) enclosure, only)
Accuracy
Typical accuracy 1% … 2% of actual volume reading (higher accuracy is pipe condition and flow profile dependent)
Repeatability 0.05% … 0.1%, of actual volume reading, for 1.5 … 30 m/s (5 … 100 ft/s) velocities (pipe condition dependent)
Zero drift 0.0003 m/s (0.001 ft/s), with ZeroMatic Path active
Data refresh rate 5 Hz (80 Hz optional)
Rated operation conditions
Degree of protection
- Wall mount enclosure IP65 (NEMA 4X)
- Compact explosion proof IP65 (NEMA 7)
- Wall mount explosion proof IP66 (NEMA 7)
Gas temperature -40 … +60 °C (-40 … +140 °F) (for higher temperatures consult factory)
Ambient temperature -18 … +60 °C (0 … 140 °F)
Design
Dimensions see SITRANS F US Clamp-on „System info and selection guide“
Weight see diagrams
Power supply
- For IP65 (NEMA 4X) and IP66 (NEMA 7) - 90 … 240 V AC,50 … 60 Hz (30 VA) or 9 … 36 V DC (12 W)
- For IP65 (NEMA 7) - 90 … 240 V AC,50 … 60 Hz (15 VA) or 9 … 36 V DC (10 W)
Indication and operation
Data logger memory 1 Mbyte, programmable for 17 data functions
Display
- IP65 (NEMA 4X) and IP66 (NEMA 7) enclosures 128 x 240 pixel LCD with backlight
- IP65 (NEMA 7) enclosure 2 x 16 alphanumeric LCD display
Keypad
- IP65 (NEMA 4X) and IP66 (NEMA 7) enclosures 33 keypad buttons with tactile feedback
- IP65 (NEMA 7) enclosure 5 magnetic hall effect switches
Language options English, Spanish, German, Italian, French
Certificates and approvals
IP65 (NEMA 4X) flow display computer ratings
FM and CSA ratings I.S. Class 1, 2, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only)
ATEX ratings - Flowmeter:Ex II (1) G [EEx ia] IICEx II 3 (1) G EEx nC [ia] IIC T5 - Transducers:Ex II 1 G EEx ia IIC T5Ex II 2 G EEx m II T5 (for use with flowmeter in safe area)
CCOE rating EEx (ia)
CEPEL ratings - Flowmeter:[BR-Ex ia] IIC T6 (pending on 4 channel) - Transducers:BR-Ex ia IIC T6 IP65
GoST ratings - Flowmeter:0ExiaIICT5 - Transducers:Exia]IIC
IP65 (NEMA 7) compact explosion proof enclosure ratings
FM and CSA ratings Ex Class 1, Div 1D-I Class 2, Div 1I.S. Class 1, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only)
ATEX ratings - Flowmeter:Ex II 2 (1) G EEx d [ia] IIC T5 - Transducers:Ex II 1 G EEx ia IIC T5
CCOE rating EEx d
CEPEL ratings - Flowmeter:BR-Ex d [ia] IIC T6 - Transducers:BR-Ex ia IIC T6 IP65
IP66 (NEMA 7) wall mount explosion proof enclosure ratings
FM and CSA ratings Ex Class 1, Div 1D-I Class 2, Div 1I.S. Class 1, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only)
ATEX ratings - Flowmeter:Ex II (1) G [EEx ia] IICEx II 3 (1) G EEx nC [ia] IIC T5Ex II 2 (1) G EEx d [ia IIC] IIB T5Ex II 2 (1) G EEx d [ia IIC] IIB+H2 T5 - Transducers:Ex II 1 G EEx ia IIC T5
CEPEL ratings - Flowmeter:[BR-Ex ia] IIC T6 (pending)BR-Ex nC [ia] IIC T6 (pending)BR-Ex d [ia IIC] IIB T6 (pending)BR-Ex d [ia IIC] IIB+H2 T6 (pending) - Transducers:BR-Ex ia IIC T6 IP65

Transducer Selection Chart

High precision transducers for steel pipe with outer diameter/wall thickness ratio >10
Transducer Order Code Pipe wall (mm) Pipe wall (inches)
Size code min. max. min. max.
B1H K 2.0 3.0 0.08 0.12
B2H L 3.0 4.1 0.12 0.16
B3H T 2.7 3.3 0.106 0.128
C1H M 4.1 5.8 0.16 0.23
C2H N 5.8 8.1 0.23 0.32
D1H P 8.1 11.2 0.32 0.44
D2H Q 11.2 15.7 0.44 0.62
D3H U 7.4 9.0 0.293 0.354
D4H R 15.7 31.8 0.62 1.25

Transducer Cable Selection Chart

Transducer cable codes for length and type options
Cable length m (ft) Standard(PVC Jacket)-40 … +80 °C(-40 … +176 °F) Submersible(Polyethylene Jacket)-40 … +80 °C(-40 … +176 °F) Plenum Rated(Teflon Jacket)-40 … +200 °C(-40 … +392 °F) Armored-40 … +80 °C(-40 … +176 °F)
Order code
6 (20) K01 K11 K21 K31
15 (50) K02 K12 K22 K32
30 (100) K03 K13 K23 K33
46 (150) K04 K14 K24 K34
61 (200) K05 K15 K25 K35
91 (300) K06 K16 K26 K36

RTD Cable Selection Chart

RTD cable codes for length and type
Cable length m (ft) Standard (teflon wrapped)-40 … +200 °C(-40 … +392 °F) Submersible (extruded jacket)-40 … +200 °C(-40 … +392 °F)
Order code
6 (20) R01 R11
15 (50) R02 R12
30 (100) R03 R13
46 (150) R04 R14
61 (200) R05 R15
91 (300) R06 R16

Заказные данные

Заказной № Описание Вес (кг) Доставка Мин. зак. (шт)
7ME3610-.....-.... SITRANS FUG1010 GAS METER CLAMP-ON, IP65 (NEMA 4X) 4.1 по запросу (D) 1
7ME3611-.....-.... SITRANS FUG1010 GAS METER CLAMP-ON, IP65 (NEMA 7) COMPACT 4.4 по запросу (X) 1
7ME3612-.....-.... SITRANS FUG1010 GAS METER CLAMP-ON, IP66 (NEMA 7) WALL MOUNTED 29 по запросу (X) 1