SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

SITRANS FUH1010 Oil clamp-on

SITRANS FUH1010 clamp-on non-intrusive ultrasonic flowmeter is ideal for applications carrying crude oil, refined petroleum or liquefied gas.

SITRANS FUH1010 has three application areas: Interface detectors, volumetric flowmeters and mass or standard volume flow meters.

Особенности

For all FUH1010 products

  • Easy installation; no need to cut pipe or stop flow
  • Minimal maintenance; external transducers do not require periodic cleaning
  • No moving parts to foul or wear
  • No pressure drop or energy loss
  • Wide turn-down ratio, 30:1
  • Choice of single, dual, or optional, three or four beam versions.
  • Single beam version reduces initial investment
  • Two or optional three and four beam versions provide higher accuracy, especially where limited straight run or poor flow profile exists
  • Wide-Beam technology
  • Helps provide improved accuracy over a wide range of liquid conditions and flow rates
  • Accommodates pipelines transporting multiple liquid products
  • Zeromatic Path automatically corrects for zero drift without stopping flow

Interface detectors / Density meters (“Interface Detector”)

  • Outputs liquid density and API as a direct replacement for intrusive densitometers
  • Exceptional repeatability is maintained, independent of changes in temperature, pressure or viscosity
  • No need for straight run

Viscosity compensated volumetric flowmeters (“precision volume”)

  • Moderate cost
  • Precise measurement is maintained with automatic „Reynolds Number“ compensation for temperature and viscosity changes

Standard volume (net) mass flowmeters (“standard volume / mass”)

  • Exceptional repeatability is maintained, independent of changes in temperature, density or viscosity
  • Batch interface and product quality diagnostics provided
  • Density and API outputs provided
  • Scraper (“pig”) detection provided

Область применения

Interface detectors / Density meters

  • Precise identification of interfaces on multi-liquid pipelines
  • Rapid and precise scraper “pig” indication
  • Product identification
  • Density indication

Viscosity compensated volumetric flowmeters

  • Applications with multiple liquids having a wide viscosity range
  • Automatic gross volume compensation due to viscosity changes

Standard volume (net) mass flowmeters

  • Standard (net) volume flow measurement
  • Suitable for use in leak detection systems
  • Interface detection
  • Pig detection
  • Chemical and petrochemical processing

Дизайн

FUH1010 is available in three enclosures:

  • IP65 (NEMA 4X) Enclosure
  • Single beam
  • Dual beam
  • Optional four beam
  • IP65 (NEMA 7) Compact explosion proof enclosure
  • Single beam
  • Dual beam (option)
  • IP66 (NEMA 7) Wall mount explosion proof enclosure, waterproof
  • Single beam
  • Dual beam
  • Four beam (optional)

Функции

  • IP65 (NEMA 4X) and IP66 (NEMA 7) flow display computers have integral 33 button keypads and large (128 x 240 pixel) graphic displays visible up to 12 m (40 ft) away
  • IP65 (NEMA 7) compact flow display computer has a 2 x 16 alphanumeric LCD display
  • Current, voltage, status alarm, frequency and RS232 outputs (see specification section for details)
  • Analog inputs (see specification section for details)
  • Zeromatic Path automatically corrects for zero drift
  • Bidirectional flow operation
  • 1 MByte data logger with both site and data logger storage
  • English, Spanish, German, Italian and French language options

Технические данные

SITRANS FUH1010
Specifications for interface detectors
Accuracy
Accuracy ± 0.05 of API No.
Repeatability ± 0.01 of API No.
Specifications for volumetric and mass flowmeters
Input
Flow range ± 24 m/s (± 80 ft/s), bidirectional
Flow sensitivity 0.0003 m/s (0.001 ft/s), flow rate independent
Accuracy
Calibratable accuracy ± 0.15% … 0.3% of flow, depending on version
Batch repeatability ± 0.05% of flow, maximum
Specifications for all FUH1010 products
Input
Pipe size 6.4 mm ... 9.14 m (0.25”... 360”)
Analog inputs - Current: 4x 4 ... 20 mA (IP65 (NEMA 7) enclosure has (2))
Output
Outputs - Current: 2x 4 … 20 mA (1 kΩ at 30 V DC) - Voltage: 2x 0 … 10 V DC (5 kΩ minimum) (None for IP65 (NEMA 7) enclosure) - 1x 0 ... 5 kHz Pulse Rate, Digital Quad. (None for IP65 (NEMA 7) enclosure) - RS232 Serial Port
Optional outputs - MODBUS (not for IP65 (NEMA 7) enclosure) - Ethernet (not for IP65 (NEMA 7) enclosure) - RS232 standard - Telephone modem (not for IP65 (NEMA 7) enclosure) - Up to 4x additional 4-20mA (not for IP65 (NEMA 7)enclosure) - 4x Mercury wetted relays (not for IP65 (NEMA 7) enclosure) - Up to 4x digital pulse (not for IP65 (NEMA 7) enclosure)
Status/Alarm I/O - 4x Programmable relays(not for IP65 (NEMA 7) enclosure) - 2x Optically coupled output logic gates(for IP65 (NEMA 7) enclosure, only) - 1x Totalizer clear switch input(not for IP65 (NEMA 4X) enclosure)1) - 1x Totalizer hold switch input(not for IP65 (NEMA 7) enclosure) 1) - 1x Opto iso. totalizer clear switch input(for IP65 (NEMA 7) enclosure, only) 1) - 1x Opto iso. totalizer hold switch input(for IP65 (NEMA 7) enclosure, only) 1) 1) Totalizer switch inputs are not provided for the interface detector
Accuracy
Zero Drift 0.0003 m/s (0.001 ft/s), with ZeroMatic Path active(not provided for interface detector)
Data refresh rate 5 Hz (80 Hz output for flow rate available on special order)
Rated operation conditions
Degree of protection
- Wall mount enclosure IP65 (NEMA 4X)
- Compact explosion proof IP65 (NEMA 7)
- Wall mount explosion proof IP66 (NEMA 7)
Liquid temperature
- Standard -40 ... +120 °C (-40 ... +250 °F)
- Optional -40 ... +230 °C (-40 ... +450 °F)
Ambient temperature -18 ... +60 °C (0 ... 140 °F)
Design
Dimensions see SITRANS F US Clamp-on „System info and selection guide“
Weight see diagrams
Power supply
- IP65 (NEMA 4X) and IP66 (NEMA 7) Wall Mount - 90 ... 240 V AC, 50 … 60 Hz, 30 VA or 9 ... 36 V DC, 12 W
- IP65 (NEMA 7) Compact - 90 ... 240 V AC, 50 ... 60 Hz, 15 VA or 9 ... 36 V DC, 10 W
Indication and operation
Data logger memory 1 MByte
Display
- IP65 (NEMA 4X) and IP66 (NEMA 7) Enclosures 128 x 240 pixel LCD with backlight
- IP65 (NEMA 7) Enclosure 2 x 16 Alphanumeric LCD Display
Keypad
- IP65 (NEMA 4X) and IP66 (NEMA 7) Enclosures 33 keypad buttons with tactile feedback
- IP65 (NEMA 7) Enclosure 5 Magnetic hall effect switches
Language options English, Spanish, German, Italian, French
Certicates and approvals
IP65 (NEMA 4X) flow display computer ratings
FM and CSA ratings I.S. Class 1, 2, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only)
ATEX ratings - Flow Display Computer:Ex II (1) G [EEx ia] IICEX II 3 (1) G EEx nC [ia] IIC T5 - Transducers:Ex II 1 G EEx ia IIC T5Ex II 2 G EEx m II T5 (For use with flowmeter in safe area only)
CCOE rating EEx (ia)
CEPEL Ratings - Flowmeter: [BR-Ex ia] IIC T6 (pending on 4 channel)BR-Ex nC [ia] IIC T6 (pending) - Transducers:BR-Ex ia IIC T6 IP65
GoST ratings Flowmeter: [Exia] IIC Transducers: 0 Ex ia IIC T5
IP65 (NEMA 7) compact explosion proof enclosure ratings
FM and CSA ratings Ex Class 1, Div 1D-I Class 2, Div 1I.S. Class 1, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only)
ATEX ratings - Flowmeter:Ex II 2 (1) G EEx d [ia] IIC T5 - Transducers:Ex II 1 G EEx ia IIC T5Ex II 2 G EEx m II T5
CCOE rating EEx d
CEPEL ratings - Flowmeter:BR-Ex d [ia] IIC T6 - Transducers:BR-Ex ia IIC T6 IP65
IP66 (NEMA 7) wall mount explosion proof enclosure ratings
FM and CSA ratings Ex Class 1, Div 1D-I Class 2, Div 1I.S. Class 1, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only)
ATEX ratings - Flowmeter:Ex II (1) G [EEx ia] IICEx II 3 (1) G EEx nC [ia] IIC T5Ex II 2 (1) G EEx d [ia IIC] IIB T5Ex II 2 (1) G EEx d [ia IIC] IIB+H2 T5 - Transducers:Ex II 1 G EEx ia IIC T5
CEPEL ratings - Flowmeter:[BR-Ex ia] IIC T6 (pending)BR-Ex nC [ia] IIC T6 (pending)BR-Ex d [ia] IIC T6 (pending) - Transducers:BR-Ex ia IIC T6 IP65

Transducer Selection Charts

High precision transducers for steel pipe with outer diameter/wall thickness ratio >10
Transducer Order Code Pipe wall (mm) Pipe wall (inches)
Size code min. max. min. max.
A1H G 0.64 1.02 0.025 0.04
A2H H 1.02 1.52 0.04 0.06
A3H J 1.52 2.03 0.06 0.08
B1H K 2.03 3.05 0.08 0.12
B2H L 3.05 4.06 0.12 0.16
C1H M 4.06 5.84 0.16 0.23
C2H N 5.84 8.13 0.23 0.32
D1H P 8.13 11.18 0.32 0.44
D2H Q 11.18 15.75 0.44 0.62
D4H R 15.75 31.75 0.62 1.25
B3H T 2.7 3.3 0.106 0.128
D3H U 7.4 9.0 0.293 0.354

Transducer Cable Selection Chart

Transducer cable codes for length and type options
Cable length m (ft) Standard (PVCjacket)-40 … +80 °C(-40 … +176 °F) Submersible(polyethylene jacket)-40 … +80 °C(-40 … +176 °F) Plenum Rated(teflon jacket)-40 … +200 °C(-40 … +392 °F) Armored-40 … +80 °C(-40 … +176 °F)
Order code
6 (20) K01 K11 K21 K31
15 (50) K02 K12 K22 K32
30 (100) K03 K13 K23 K33
46 (150) K04 K14 K24 K34
61 (200) K05 K15 K25 K35
91 (300) K06 K16 K26 K36

RTD Cable Selection Chart

RTD cable codes for length and type
Cable length m (ft) Standard (teflon wrapped) -40 ... +200 °C(-40 … +392 °F) Submersible (extruded jacket) -40 ... +200 °C(-40 … +392 °F)
Order code
6 (20) R01 R11
15 (50) R02 R12
30 (100) R03 R13
46 (150) R04 R14
61 (200) R05 R15
91 (300) R06 R16

Заказные данные

Заказной № Описание Вес (кг) Доставка Мин. зак. (шт)
7ME3600-.....-.... SITRANS FUH1010 OIL CLAMP-ON, IP65 (NEMA 4X) 4.1 по запросу (D) 1
7ME3601-.....-.... SITRANS FUH1010 OIL CLAMP-ON, IP65 (NEMA 7) COMPACT 4.4 по запросу (X) 1
7ME3602-.....-.... SITRANS FUH1010 OIL CLAMP-ON, IP66 (NEMA 7) WALL MOUNTED 29 по запросу (X) 1