SITRANS FUH1010 clamp-on non-intrusive ultrasonic flowmeter is ideal for applications carrying crude oil, refined petroleum or liquefied gas.
SITRANS FUH1010 has three application areas: Interface detectors, volumetric flowmeters and mass or standard volume flow meters.
Особенности
For all FUH1010 products
- Easy installation; no need to cut pipe or stop flow
- Minimal maintenance; external transducers do not require periodic cleaning
- No moving parts to foul or wear
- No pressure drop or energy loss
- Wide turn-down ratio, 30:1
- Choice of single, dual, or optional, three or four beam versions.
- Single beam version reduces initial investment
- Two or optional three and four beam versions provide higher accuracy, especially where limited straight run or poor flow profile exists
- Wide-Beam technology
- Helps provide improved accuracy over a wide range of liquid conditions and flow rates
- Accommodates pipelines transporting multiple liquid products
- Zeromatic Path automatically corrects for zero drift without stopping flow
Interface detectors / Density meters (“Interface Detector”)
- Outputs liquid density and API as a direct replacement for intrusive densitometers
- Exceptional repeatability is maintained, independent of changes in temperature, pressure or viscosity
- No need for straight run
Viscosity compensated volumetric flowmeters (“precision volume”)
- Moderate cost
- Precise measurement is maintained with automatic „Reynolds Number“ compensation for temperature and viscosity changes
Standard volume (net) mass flowmeters (“standard volume / mass”)
- Exceptional repeatability is maintained, independent of changes in temperature, density or viscosity
- Batch interface and product quality diagnostics provided
- Density and API outputs provided
- Scraper (“pig”) detection provided
Область применения
Interface detectors / Density meters
- Precise identification of interfaces on multi-liquid pipelines
- Rapid and precise scraper “pig” indication
- Product identification
- Density indication
Viscosity compensated volumetric flowmeters
- Applications with multiple liquids having a wide viscosity range
- Automatic gross volume compensation due to viscosity changes
Standard volume (net) mass flowmeters
- Standard (net) volume flow measurement
- Suitable for use in leak detection systems
- Interface detection
- Pig detection
- Chemical and petrochemical processing
Дизайн
FUH1010 is available in three enclosures:
- IP65 (NEMA 4X) Enclosure
- Single beam
- Dual beam
- Optional four beam
- IP65 (NEMA 7) Compact explosion proof enclosure
- Single beam
- Dual beam (option)
- IP66 (NEMA 7) Wall mount explosion proof enclosure, waterproof
- Single beam
- Dual beam
- Four beam (optional)
Функции
- IP65 (NEMA 4X) and IP66 (NEMA 7) flow display computers have integral 33 button keypads and large (128 x 240 pixel) graphic displays visible up to 12 m (40 ft) away
- IP65 (NEMA 7) compact flow display computer has a 2 x 16 alphanumeric LCD display
- Current, voltage, status alarm, frequency and RS232 outputs (see specification section for details)
- Analog inputs (see specification section for details)
- Zeromatic Path automatically corrects for zero drift
- Bidirectional flow operation
- 1 MByte data logger with both site and data logger storage
- English, Spanish, German, Italian and French language options
Технические данные
| SITRANS FUH1010 | |
|---|---|
| Specifications for interface detectors | |
| Accuracy | |
| Accuracy | ± 0.05 of API No. |
| Repeatability | ± 0.01 of API No. |
| Specifications for volumetric and mass flowmeters | |
| Input | |
| Flow range | ± 24 m/s (± 80 ft/s), bidirectional |
| Flow sensitivity | 0.0003 m/s (0.001 ft/s), flow rate independent |
| Accuracy | |
| Calibratable accuracy | ± 0.15% … 0.3% of flow, depending on version |
| Batch repeatability | ± 0.05% of flow, maximum |
| Specifications for all FUH1010 products | |
| Input | |
| Pipe size | 6.4 mm ... 9.14 m (0.25”... 360”) |
| Analog inputs | - Current: 4x 4 ... 20 mA (IP65 (NEMA 7) enclosure has (2)) |
| Output | |
| Outputs | - Current: 2x 4 … 20 mA (1 kΩ at 30 V DC) - Voltage: 2x 0 … 10 V DC (5 kΩ minimum) (None for IP65 (NEMA 7) enclosure) - 1x 0 ... 5 kHz Pulse Rate, Digital Quad. (None for IP65 (NEMA 7) enclosure) - RS232 Serial Port |
| Optional outputs | - MODBUS (not for IP65 (NEMA 7) enclosure) - Ethernet (not for IP65 (NEMA 7) enclosure) - RS232 standard - Telephone modem (not for IP65 (NEMA 7) enclosure) - Up to 4x additional 4-20mA (not for IP65 (NEMA 7)enclosure) - 4x Mercury wetted relays (not for IP65 (NEMA 7) enclosure) - Up to 4x digital pulse (not for IP65 (NEMA 7) enclosure) |
| Status/Alarm I/O | - 4x Programmable relays(not for IP65 (NEMA 7) enclosure) - 2x Optically coupled output logic gates(for IP65 (NEMA 7) enclosure, only) - 1x Totalizer clear switch input(not for IP65 (NEMA 4X) enclosure)1) - 1x Totalizer hold switch input(not for IP65 (NEMA 7) enclosure) 1) - 1x Opto iso. totalizer clear switch input(for IP65 (NEMA 7) enclosure, only) 1) - 1x Opto iso. totalizer hold switch input(for IP65 (NEMA 7) enclosure, only) 1) 1) Totalizer switch inputs are not provided for the interface detector |
| Accuracy | |
| Zero Drift | 0.0003 m/s (0.001 ft/s), with ZeroMatic Path active(not provided for interface detector) |
| Data refresh rate | 5 Hz (80 Hz output for flow rate available on special order) |
| Rated operation conditions | |
| Degree of protection | |
| - Wall mount enclosure | IP65 (NEMA 4X) |
| - Compact explosion proof | IP65 (NEMA 7) |
| - Wall mount explosion proof | IP66 (NEMA 7) |
| Liquid temperature | |
| - Standard | -40 ... +120 °C (-40 ... +250 °F) |
| - Optional | -40 ... +230 °C (-40 ... +450 °F) |
| Ambient temperature | -18 ... +60 °C (0 ... 140 °F) |
| Design | |
| Dimensions | see SITRANS F US Clamp-on „System info and selection guide“ |
| Weight | see diagrams |
| Power supply | |
| - IP65 (NEMA 4X) and IP66 (NEMA 7) Wall Mount | - 90 ... 240 V AC, 50 … 60 Hz, 30 VA or 9 ... 36 V DC, 12 W |
| - IP65 (NEMA 7) Compact | - 90 ... 240 V AC, 50 ... 60 Hz, 15 VA or 9 ... 36 V DC, 10 W |
| Indication and operation | |
| Data logger memory | 1 MByte |
| Display | |
| - IP65 (NEMA 4X) and IP66 (NEMA 7) Enclosures | 128 x 240 pixel LCD with backlight |
| - IP65 (NEMA 7) Enclosure | 2 x 16 Alphanumeric LCD Display |
| Keypad | |
| - IP65 (NEMA 4X) and IP66 (NEMA 7) Enclosures | 33 keypad buttons with tactile feedback |
| - IP65 (NEMA 7) Enclosure | 5 Magnetic hall effect switches |
| Language options | English, Spanish, German, Italian, French |
| Certicates and approvals | |
| IP65 (NEMA 4X) flow display computer ratings | |
| FM and CSA ratings | I.S. Class 1, 2, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only) |
| ATEX ratings | - Flow Display Computer:Ex II (1) G [EEx ia] IICEX II 3 (1) G EEx nC [ia] IIC T5 - Transducers:Ex II 1 G EEx ia IIC T5Ex II 2 G EEx m II T5 (For use with flowmeter in safe area only) |
| CCOE rating | EEx (ia) |
| CEPEL Ratings | - Flowmeter: [BR-Ex ia] IIC T6 (pending on 4 channel)BR-Ex nC [ia] IIC T6 (pending) - Transducers:BR-Ex ia IIC T6 IP65 |
| GoST ratings | Flowmeter: [Exia] IIC Transducers: 0 Ex ia IIC T5 |
| IP65 (NEMA 7) compact explosion proof enclosure ratings | |
| FM and CSA ratings | Ex Class 1, Div 1D-I Class 2, Div 1I.S. Class 1, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only) |
| ATEX ratings | - Flowmeter:Ex II 2 (1) G EEx d [ia] IIC T5 - Transducers:Ex II 1 G EEx ia IIC T5Ex II 2 G EEx m II T5 |
| CCOE rating | EEx d |
| CEPEL ratings | - Flowmeter:BR-Ex d [ia] IIC T6 - Transducers:BR-Ex ia IIC T6 IP65 |
| IP66 (NEMA 7) wall mount explosion proof enclosure ratings | |
| FM and CSA ratings | Ex Class 1, Div 1D-I Class 2, Div 1I.S. Class 1, Div 1N-I Class 1, Div 2S Class 2, Div 2 (FM only) |
| ATEX ratings | - Flowmeter:Ex II (1) G [EEx ia] IICEx II 3 (1) G EEx nC [ia] IIC T5Ex II 2 (1) G EEx d [ia IIC] IIB T5Ex II 2 (1) G EEx d [ia IIC] IIB+H2 T5 - Transducers:Ex II 1 G EEx ia IIC T5 |
| CEPEL ratings | - Flowmeter:[BR-Ex ia] IIC T6 (pending)BR-Ex nC [ia] IIC T6 (pending)BR-Ex d [ia] IIC T6 (pending) - Transducers:BR-Ex ia IIC T6 IP65 |
Transducer Selection Charts
| High precision transducers for steel pipe with outer diameter/wall thickness ratio >10 | |||||
|---|---|---|---|---|---|
| Transducer | Order Code | Pipe wall (mm) | Pipe wall (inches) | ||
| Size code | min. | max. | min. | max. | |
| A1H | G | 0.64 | 1.02 | 0.025 | 0.04 |
| A2H | H | 1.02 | 1.52 | 0.04 | 0.06 |
| A3H | J | 1.52 | 2.03 | 0.06 | 0.08 |
| B1H | K | 2.03 | 3.05 | 0.08 | 0.12 |
| B2H | L | 3.05 | 4.06 | 0.12 | 0.16 |
| C1H | M | 4.06 | 5.84 | 0.16 | 0.23 |
| C2H | N | 5.84 | 8.13 | 0.23 | 0.32 |
| D1H | P | 8.13 | 11.18 | 0.32 | 0.44 |
| D2H | Q | 11.18 | 15.75 | 0.44 | 0.62 |
| D4H | R | 15.75 | 31.75 | 0.62 | 1.25 |
| B3H | T | 2.7 | 3.3 | 0.106 | 0.128 |
| D3H | U | 7.4 | 9.0 | 0.293 | 0.354 |
Transducer Cable Selection Chart
| Transducer cable codes for length and type options | ||||
|---|---|---|---|---|
| Cable length m (ft) | Standard (PVCjacket)-40 … +80 °C(-40 … +176 °F) | Submersible(polyethylene jacket)-40 … +80 °C(-40 … +176 °F) | Plenum Rated(teflon jacket)-40 … +200 °C(-40 … +392 °F) | Armored-40 … +80 °C(-40 … +176 °F) |
| Order code | ||||
| 6 (20) | K01 | K11 | K21 | K31 |
| 15 (50) | K02 | K12 | K22 | K32 |
| 30 (100) | K03 | K13 | K23 | K33 |
| 46 (150) | K04 | K14 | K24 | K34 |
| 61 (200) | K05 | K15 | K25 | K35 |
| 91 (300) | K06 | K16 | K26 | K36 |
RTD Cable Selection Chart
| RTD cable codes for length and type | ||
|---|---|---|
| Cable length m (ft) | Standard (teflon wrapped) -40 ... +200 °C(-40 … +392 °F) | Submersible (extruded jacket) -40 ... +200 °C(-40 … +392 °F) |
| Order code | ||
| 6 (20) | R01 | R11 |
| 15 (50) | R02 | R12 |
| 30 (100) | R03 | R13 |
| 46 (150) | R04 | R14 |
| 61 (200) | R05 | R15 |
| 91 (300) | R06 | R16 |
Заказные данные
| Заказной № | Описание | Вес (кг) | Доставка | Мин. зак. (шт) |
|---|---|---|---|---|
| 7ME3600-.....-.... | SITRANS FUH1010 OIL CLAMP-ON, IP65 (NEMA 4X) | 4.1 | по запросу (D) | 1 |
| 7ME3601-.....-.... | SITRANS FUH1010 OIL CLAMP-ON, IP65 (NEMA 7) COMPACT | 4.4 | по запросу (X) | 1 |
| 7ME3602-.....-.... | SITRANS FUH1010 OIL CLAMP-ON, IP66 (NEMA 7) WALL MOUNTED | 29 | по запросу (X) | 1 |