Fault · SINAMICS G130, G150, S120, S150

F36885Hub DRIVE-CLiQ (CU): Cyclic data transfer error

What it means

F36885 is raised when the cyclic data transfer over DRIVE-CLiQ between a DRIVE-CLiQ Hub Module and the Control Unit (CU) fails: the two nodes no longer send and receive in synchronism. The message value names the hub concerned (component number, %1) and the reason for the breakdown (fault cause, %2); the drive stores this coded as 0000yyxx hex in r0949 and r2124. The neighbouring hub codes F36851, F36860, F36875, F36886, F36887, F36895, F36896 and F36899 are described on their own pages.

Why it appears

  • DRIVE-CLiQ communication error from the DRIVE-CLiQ Hub Module in question to the Control Unit — the nodes do not send and receive in synchronism.
  • The manual distinguishes several fault causes for this breakdown: a sign-of-life bit that is not set in the receive telegram, a cyclic telegram that never arrives, a timeout in the telegram receive list, a timeout in the telegram send list, and an error at the transition to cyclic operation. The codes and exact wording are decoded in the fault value section below.

What to check

  1. Read the message value in r0949 (or in r2124) and decode it as 0000yyxx hex — yy identifies the hub (component number) whose transfer to the CU failed, xx gives the fault cause.
  2. Check the supply voltage of the component involved.
  3. Carry out a POWER ON.
  4. Replace the component involved.

Reading the message value

  • The drive enters the component number into %1 and the fault cause into %2; in the message value (r0949/r2124) the information is coded as 0000yyxx hex, where yy is the component number and xx the error cause.
  • Fault cause 26 (= 1A hex): Sign-of-life bit in the receive telegram not set and the receive telegram is too early.
  • Fault cause 33 (= 21 hex): The cyclic telegram has not been received.
  • Fault cause 34 (= 22 hex): Timeout in the telegram receive list.
  • Fault cause 64 (= 40 hex): Timeout in the telegram send list.
  • Fault cause 98 (= 62 hex): Error at the transition to cyclic operation.

Parameters the manual names

  • r0949 (fault value) — holds the coded message value of this fault; decode it as 0000yyxx hex to identify the hub involved and the fault cause.
  • r2124 (alarm value) — the manual names this alarm value alongside r0949 as the location of the same coded value for this message.

Acknowledging and restarting

The drive takes no automatic action in response to this fault, and the message can be acknowledged immediately. It only stays cleared once the hub and the CU again exchange cyclic telegrams in synchronism — if the fault returns, work through the checks above in order.

What differs between the drive families

Straight from the manuals' own fields — F36885 is not described identically everywhere.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150Internal (DRIVE-CLiQ) communication error (12)Terminal Board (TB)SINAMICS S120, S150 List Manual · p. 3256
G130, G150NONEIMMEDIATELYInternal (DRIVE-CLiQ) communication error (12)Terminal Board (TB)SINAMICS G130, G150 List Manual · p. 1918

The drives this code lives on

F36885 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does fault F36885 mean on a SINAMICS drive?

The cyclic DRIVE-CLiQ data transfer between a DRIVE-CLiQ Hub Module and the Control Unit has failed — the nodes do not send and receive in synchronism.

How do I identify the affected hub with F36885?

Read the message value in r0949 (or in r2124) and decode it as 0000yyxx hex: yy is the component number of the hub, xx is the fault cause.

What does fault cause 26 in F36885 mean?

Fault cause 26 (= 1A hex) means the sign-of-life bit in the receive telegram is not set and the receive telegram arrives too early. The other causes 33, 34, 64 and 98 are decoded on the page.

How do I clear and acknowledge F36885?

Check the supply voltage of the component involved, carry out a POWER ON, and replace the component if the fault persists. The fault triggers no automatic reaction and can be acknowledged immediately.