What it means
F30885 reports a cyclic DRIVE-CLiQ data transfer error inside the converter: communication from the power unit to the involved Control Unit has failed because the nodes no longer send and receive in synchronism. The drive coasts down and the fault must be acknowledged before it will run again. The message value tells you which component is affected and which of the possible fault causes triggered the message, so read it out before replacing anything.
Why it appears
- A DRIVE-CLiQ communication error has occurred in the cyclic data transfer from the power unit to the involved Control Unit — the nodes do not send and receive in synchronism.
- Both manuals that describe this fault give the same underlying cause; the specific reason is identified by the fault cause coded in the message value (see the fault value list below).
What to check
- Check the power supply voltage of the component involved.
- Carry out a POWER ON.
- Replace the component involved.
Reading the message value
- The message value consists of two placeholders: %1 is the component number, %2 is the fault cause.
- The individual information is coded in the message value (r0949/r2124) as 0000yyxx hex, where yy is the component number and xx is the error cause.
- Fault cause 26 (= 1A hex): the sign-of-life bit in the receive telegram is not set and the receive telegram is too early.
- Fault cause 33 (= 21 hex): the cyclic telegram has not been received.
- Fault cause 34 (= 22 hex): timeout in the telegram receive list.
- Fault cause 64 (= 40 hex): timeout in the telegram send list.
- Fault cause 98 (= 62 hex): error at the transition to cyclic operation.
Parameters the manual names
- r0949 (fault value): read the coded message value of F30885 here — 0000yyxx hex, with the component number in yy and the fault cause in xx.
- r2124 (alarm value): named by the manual together with r0949 as the place where the same coded message value is stored.
- p9915 (DRIVE-CLiQ data transfer error shutdown threshold master / DQ fault master): the remedy entry for this fault refers to this parameter as related reading.
Acknowledging and restarting
The fault must be acknowledged immediately once it occurs. The remedy sequence of the manual is: check the power supply voltage of the affected component, then carry out a POWER ON; if the fault still occurs, replace the component involved.
The same on every family
Every manual that describes F30885 gives it the same reaction, acknowledgement and message class.
| Drive family | Reaction | Acknowledge | Message class | Component | Manual |
|---|---|---|---|---|---|
| G130, G150 | OFF2 | IMMEDIATELY | Internal (DRIVE-CLiQ) communication error (12) | Power Module | SINAMICS G130, G150 List Manual · p. 1711 |
| S120, S150 | OFF2 | IMMEDIATELY | Internal (DRIVE-CLiQ) communication error (12) | Power Module | SINAMICS S120, S150 List Manual · p. 3020 |
The drives this code lives on
F30885 is described for G130, G150, S120, S150. These are the converters of those families in our catalogue — price on request.
Questions technicians ask
What does fault F30885 mean on a SINAMICS drive?
It reports a cyclic DRIVE-CLiQ data transfer error between the power unit and the Control Unit: the nodes do not send and receive in synchronism, and the drive coasts down until the fault is acknowledged.
How do I clear F30885?
Check the power supply voltage of the component involved, carry out a POWER ON, and replace the component involved if the fault persists. The fault itself must be acknowledged immediately.
How is the fault cause of F30885 coded?
In the message value (r0949/r2124) as 0000yyxx hex: yy is the component number and xx the fault cause — for example 33 (= 21 hex) means the cyclic telegram was not received.
What does fault cause 98 for F30885 indicate?
Fault cause 98 (= 62 hex) stands for an error at the transition to cyclic operation and is read from the xx part of the coded message value.
Codes next to this one
Source
Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.