A13030Trial License activated

What it means

A13030 — Trial License activated belongs to the drive's licensing messages. It appears because the "Trial License" function was activated and one of the available periods is expiring. The alarm announces the approaching end of such a period and then goes away by itself; no corrective work is connected with it. The directly adjacent alarms A13031 (Trial License period expired), A13032 (Trial License last period activated) and A13033 (Trial License last period expired) continue this message group, and the further licensing alarms A13000, A13001 and A13021 are described on their own pages.

Why it appears

  • The Trial License function is activated on the drive, and one of its available periods is approaching its end.

What to check

  1. No remedial action is required: the manual states that the remedy is not necessary, because the alarm withdraws automatically once the periods have expired.
  2. To see the current licensing state, read r9919 (Licensing Trial License status); the alarm references this status parameter alongside p9918 (Licensing active Trial License).

Parameters the manual names

  • p9918 (Licensing active Trial License) — the licensing parameter for the active Trial License that this alarm reports; the alarm's cause refers to it.
  • r9919 (Licensing Trial License status) — shows the Trial License status; use it to check the licensing state connected with this alarm.

Acknowledging and restarting

Nothing has to be acknowledged or reset here. The manual's remedy reads simply: Not necessary. The alarm is automatically withdrawn after the periods have expired. The drive therefore removes the alarm on its own.

The same on every family

Every manual that describes A13030 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
S120, S150NONENONEError in the parameterization / configuration / commissioning procedure (18)Control Unit (CU)SINAMICS S120, S150 List Manual · p. 2933

The drives this code lives on

A13030 is described for S120, S150. These are the converters of those families in our catalogue — price on request.

Questions technicians ask

What does SINAMICS alarm A13030 "Trial License activated" mean?

It reports that the "Trial License" function was activated on the drive and one of the available periods is expiring. The alarm withdraws itself automatically once the periods have expired.

How do I acknowledge or reset A13030?

No acknowledgment or reset is needed. The manual states the remedy is not necessary, because the alarm is automatically withdrawn after the periods have expired.

Which parameters belong to A13030?

p9918 (Licensing active Trial License) and r9919 (Licensing Trial License status) are referenced with this alarm. r9919 shows the Trial License status, and p9918 belongs to the active Trial License.

Are there related licensing alarms?

Yes. A13031, A13032 and A13033 are the neighbouring Trial License alarms, and A13000, A13001 and A13021 cover further licensing conditions. Each is described on its own page.