SiemensETIJohnson ControlsIFMSICKWIKABosch RexrothELKO EPHYUNDAIABBVEGAKSR KUEBLERAlfa Laval

Alarm · SINAMICS G120XA

A07325Drive: Hibernation mode active - drive automatically switched-on again

What it means

A07325 (Drive: Hibernation mode active - drive automatically switched-on again) reports that the hibernation function of the drive is active; the function is configured with p2398. While it is active, the drive powers itself up again automatically as soon as the restart conditions are present. The alarm only reports this state — no remedy is necessary.

Why it appears

  • The hibernation function configured in p2398 is active; the drive switches itself on again automatically once the restart conditions are present.

Parameters the manual names

  • p2398 (hibernation mode operating type) — the setting through which the hibernation function is configured; while A07325 is shown, the function selected in this parameter is running.

Acknowledging and restarting

No acknowledgement is required and no remedy is necessary. The alarm is withdrawn automatically: it disappears when the motor is restarted or when the motor is manually switched off.

The same on every family

Every manual that describes A07325 gives it the same reaction, acknowledgement and message class.

Drive familyReactionAcknowledgeMessage classComponentManual
G120XANONENONESINAMICS G120XA PN converter · p. 1125

Questions technicians ask

What does alarm A07325 mean on a SINAMICS drive?

It reports that the hibernation function is active. The drive powers itself up again automatically as soon as the restart conditions are present.

How do I clear or acknowledge A07325?

You do not have to — no acknowledgement and no remedy are necessary. The alarm is withdrawn automatically when the motor is restarted or when the motor is manually switched off.

Which parameter is behind the A07325 hibernation alarm?

p2398, the hibernation mode operating type. The alarm indicates that the hibernation function configured with this parameter is active.

Codes next to this one

Source

Written from Siemens' own List Manuals and operating instructions; every number, designation and parameter on this page is checked against them before publication.

All SINAMICS codes: fault and alarm codes · the A07xxx group · SINAMICS manuals · Siemens manuals