AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
TRN 1
TRN
On order
WIKA · Temperature measurement · Family TRN

Resistance thermometer for civil nuclear applications

Resistance thermometer for civil nuclear applications with IEEE conformity, suitable for reactor buildings, peripherals, HVAC, and accident-proof applications.
Range
-50…600 °C
Output
80 ... 314 Ω
Accuracy
Class A: ±(0.15 + 0.0020 |t|) °C; Class B: ±(0.30 + 0.0050 |t|) °C
Protection
IP65
RoHSUKCACE
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

Thermometer for use in nuclear power plants comprise:

- ■ Resistance thermometer, model TRN - ■ Thermowell/protection tube - ■ Accessories

The model TRN resistance thermometer can be combined with a large number of thermowell/protection tube designs. Operation without thermowell/protection tube is only recommended in certain applications.

Cable couplings are available as accessories.

Special features

  • Measuring range from -50 ... +600 °C [-58 ... +1,112 °F]
  • For mounting in all standard thermowell/protection tube designs
  • Spring-loaded measuring insert
  • Pt100 measuring resistors
Identification
ModelTRN
SubcategoryResistance thermometer
Measuring range
Temperature ranges−50…+600 °C · −50…+400 °C · −30…+300 °C
Accuracy
Accuracy classClass A: ±(0.15 + 0.0020 |t|) °C; Class B: ±(0.30 + 0.0050 |t|) °C
Process conditions
Process temperature−50…+600 °C
Electrical characteristics
Output signal80 ... 314 Ω
Electrical connectionHarting connector, TS connector LOCA, Connector LOCA + SA
Materials
Probe materialStainless steel 1.4571
Operating environment
Ambient temperature−40…+80 °C
IP ratingIP65
Certifications and approvals
Certifications
RoHSUKCACE
Additional details
Sensor typePt100
Sensor classA, B
Probe diameter4 mm
ThermowellYes
Datasheet languagesEN
Tables from datasheet
Measurement principleDesignOperating conditions (connector)
Code / PlaceholderXYZ
ExampleTRN-IH
DescriptionResistance thermometerImmersedHarting connector
ModelDescription
TRN-IzImmersed, with and without thermowell/protection tube (I = immersed)
TRN-AzRoom air sensor (A = ambient)
TRN-SzSurface probe (S = surface); for versions, see model TR50, data sheetTE 60.50
TRN-PzResistance Thermometer for cooling ponds and similar applications (P = pool)
TRN-GzCombined sensor (G = gradient)
TRN-yH (14481879)TRN-yA (14479583)TRN-yC (14529466)
Connector descriptionHarting (HAN7D...)TS connector LOCAConnector LOCA + SA
IP ingress protectionIP65 (IP67 possible without radiation)IP68IP68
IEEE ratingN1E Harsch1E1E + SA
Qualified lifetime12 years at 45 °C ambient tem- perature55 years at 45 °C ambient tem- perature55 years at 45 °C ambient tem- perature
Maximum radiation during normal operation100 kGy TID - 'Total Integrated Dose'250 kGy TID - 'Total Integrated Dose'250 kGy TID - 'Total Integrated Dose'
Maximum radiation during accident-600 kGy (TID: 850 kGy)600 kGy (TID: 850 kGy)
LOCA test conditions-max. 195 °C, 5.4 bar (g), 24 h1 h at 250 °C; 5 h at 207 °C
Accidental radiation after LOCA--1,000 kGy (TID: 1,850 kGy)
Humidity90 %relative humidity100 %relative humidity100 %relative humidity
Ambient and storage temper- ature-40 …+80 °C [-40 …+176 °F]-40 …+80 °C [-40 …+176 °F]-40 …+80 °C [-40 …+176 °F]
Measuring tipØ4mmMeasuring tipØ4mm
Thermometer version
Sensor1 x Pt1001 x Pt100 / Differential thermocouple 1)
Connection method4-wire3-wire
Diameter4mmPt100: 4 mm/ Differential thermocouple:1.2mm
Probe length150 ...1,100mm150 ...1,100mm
MaterialStainless steel 1.4571Stainless steel 1.4571
Response time in seconds (+/-10 %)
t 0.55.0Pt100: 5.0 / Differential thermocouple: < 3 incl. calculation in the transmitter
t 0.636.0Pt100: 6.0 / Differential thermocouple: < 3 incl. calculation in the transmitter
t 0.912.0Pt100: 12.0 / Differential thermocouple: < 3 incl. calculation in the transmitter
View all (7)
LogoDescriptionRegion
EU declaration of conformityEuropean Union
UKCA Restriction of hazardous substances (RoHS) regulationsUnited Kingdom
CertificatesMeasurement accuracyMaterial certificate 1)
2.2 test reportxx
3.1 inspection certificatexx
DAkkS calibration certificatex-
ModelDescriptionOrder number
Cable couplingsMounting type depending on cable / customer specificationcustomer-specific