AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
TR81 1
TR81
On order
WIKA · Temperature measurement · Family TR

Resistance thermometer for flue gas temperature measurements

Resistance thermometer for flue gas temperature measurements with thermowell model TW81, suitable for gaseous media up to 1 bar, with replaceable measuring insert and optional transmitter.
Range
-196…600 °C
Output
4-20mA · HART
Accuracy
Class B
Protection
IP53
RoHSEU declaration of conformityEMC directive EN 61326CEEACINMETRONEPSIKCPESODNOP-MakNIIGOSTKazInMetrMTSCHSBelGIMUkrSEPROUzstandard[II 2G Ex eb IIC T1 ... T6 Gb][II 3G Ex ec IIC T1 ... T6 Gc X][II 3D Ex tc IIIC TX °C Dc X][II 1G Ex ia IIC T1 ... T6 Ga][II 2G Ex ia IIC T1 ... T6 Gb][II 2D Ex tb IIIC TX °C Db][II 3G Ex nA IIC T1 ... T6 Gc X]IECExKCs-KOSHA[II 1G Ex iia IIC T1 ... T6 Ga][II 2G Ex iia IIC T1 ... T6 Gb][II 2D Ex tb IIC TX °C Db][II 3D Ex tc IIC TX °C Dc X][Ex iia IIC T1 ... T6 Ga][Ex iia IIC T1 ... T6 Ga/Gb][Ex iia IIC T1 ... T6 Gb][Ex iia IIC T125 ... T65 °C Da][0 Ex iia IIC T6 ... T1 Ga X][1 Ex iia IIC T6 ... T1 Gb X][Ex nA IIC T6 ... T1 Gc X][Ex iia IIC T3 ... T6 Ga][Ex iia IIC T3 ... T6 Ga/Gb][Ex iia IIC T3 ... T6 Gb][Exia IIC T1~~T6Ga][Exia IIC T1~~T6Ga/Gb][Exia IIC T1~T6Gb][Exia IIC T4...T6][Exib IIC T4...T6][II1G Exia IIC T3...T6Ga][II1/2G Exia IIC T3...T6Ga/Gb][II2G Exia IIC T3...T6Gb][II1D Exia IIIC T125...T65℃Da][II2D Exia IIIC T125...T65℃Db]
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

These straight resistance thermometers consist of a form B connection head, a measuring insert in accordance with DIN 43735 and a model TW81 thermowell. In addition to DIN form A or C thermowells, customer-specific versions are possible.

Possible process connections are stop flange or threaded bushing - the latter can realise a gas-tight connection.

These thermometers are suitable for gaseous media in the low pressure range (up to approx. 1 bar). Different thermowell materials, with or without enamelling, ensure matching to the respective thermal load.

Measuring insert is replaceable. This enables inspection, measuring equipment monitoring or, when servicing is necessary, replacement while the plant is running. The choice of standard lengths assists with short delivery times and the possibility of stocking spare parts.

for further approvals see page 2

Resistance thermometer for flue gas temperature measurements, model TR81

Thermowell material, connection head and sensor can each be selected to suit the respective application.

Optionally, a transmitter can be built in. Among the advantages of a built-in transmitter is an increased reliability of the signal transmission.

Special features

  • Application ranges up to +600 °C [+1,112 °F]
  • Thermowell from heat-resistant steel
  • Measuring insert replaceable
  • Gas-tight process connection (option)
Identification
ModelTR81
Product familyTR
Subcategorystraight resistance thermometer
Measuring range
Temperature ranges−196…+600 °C · −100…+450 °C · −50…+250 °C · −50…+500 °C · −30…+300 °C · +0…+150 °C
Accuracy
Accuracy classClass B
Safety integrity level (SIL)SIL 2
Process conditions
Process connection
stop flangethreaded bushingG 1G 1½G ½G ¾1 ½ inch, 150 lbs, RF1 ½ inch, 300 lbs, RF2 inch, 150 lbs, RF2 inch, 300 lbs, RF3 inch, 150 lbs, RF3 inch, 300 lbs, RF4 inch, 150 lbs, RF4 inch, 300 lbs, RFMating flangeFlange welded to thermowell
Process temperature−196…+600 °C
Electrical characteristics
Output signal4-20mA · HART · FOUNDATION Fieldbus · PROFIBUS-PA
Power supplyvaries by transmitter model
Electrical connectionM20 x 1.5
Materials
Probe materialstainless steel, carbon steel 1.0305, stainless steel 1.4571, stainless steel 1.4841, stainless steel 1.4762
Thermowell materialcarbon steel 1.0305, carbon steel 1.0305 enamelled, stainless steel 1.4571, stainless steel 1.4841, stainless steel 1.4762, Carbon steel 1.0305, enamelled
Operating environment
Ambient temperature−20…+85 °C
IP ratingIP53
Certifications and approvals
Certifications
RoHSEU declaration of conformityEMC directive EN 61326CEEACINMETRONEPSIKCPESODNOP-MakNIIGOSTKazInMetrMTSCHSBelGIMUkrSEPROUzstandard
Explosion protection
[II 2G Ex eb IIC T1 ... T6 Gb][II 3G Ex ec IIC T1 ... T6 Gc X][II 3D Ex tc IIIC TX °C Dc X][II 1G Ex ia IIC T1 ... T6 Ga][II 1/2G Ex ia IIC T1 ... T6 Ga/Gb][II 2G Ex ia IIC T1 ... T6 Gb][II 1D Ex ia IIIC T125 ... T65 °C Da][II 1/2D Ex ia IIIC T125 ... T65 °C Da/Db][II 2D Ex ia IIIC T125 ... T65 °C Db][II 2D Ex tb IIIC TX °C Db][II 3G Ex nA IIC T1 ... T6 Gc X]IECExEACINMETRONEPSIKCs-KOSHAPESODNOP-MakNII[II 1G Ex iia IIC T1 ... T6 Ga][II 1/2G Ex iia IIC T1 ... T6 Ga/Gb][II 2G Ex iia IIC T1 ... T6 Gb][II 1D Ex iia IIC T125 ... T65 °C Da][II 1/2D Ex iia IIC T125 ... T65 °C Da/Db][II 2D Ex iia IIC T125 ... T65 °C Db][II 2D Ex tb IIC TX °C Db][II 3D Ex tc IIC TX °C Dc X][Ex iia IIC T1 ... T6 Ga][Ex iia IIC T1 ... T6 Ga/Gb][Ex iia IIC T1 ... T6 Gb][Ex iia IIC T125 ... T65 °C Da][Ex iia IIC T125 ... T65 °C Da/Db][0 Ex iia IIC T6 ... T1 Ga X][1 Ex iia IIC T6 ... T1 Gb X][Ex iia IIC T80 ... T440 °C Da X][Ex iia IIC T80 ... T440 °C Db X][Ex nA IIC T6 ... T1 Gc X][Ex iia IIC T3 ... T6 Ga][Ex iia IIC T3 ... T6 Ga/Gb][Ex iia IIC T3 ... T6 Gb][Exia IIC T1~~T6Ga][Exia IIC T1~~T6Ga/Gb][Exia IIC T1~T6Gb][Exia IIC T4...T6][Exib IIC T4...T6][II1G Exia IIC T3...T6Ga][II1/2G Exia IIC T3...T6Ga/Gb][II2G Exia IIC T3...T6Gb][II1D Exia IIIC T125...T65℃Da][II1/2D Exia IIIC T125...T65℃Da/Db][II2D Exia IIIC T125...T65℃Db]
Additional details
Sensor typePt100
Sensor classA
Probe length2000 mm
Probe diameter15 mm
ThermowellYes
Thermowell formForm B
Datasheet languagesEN
Tables from datasheet
LogoDescriptionCountry
EU declaration of conformity ■ EMCdirective 1) EN 61326 emission (group 1, class B) and immunity (industrial application)European Union
IECEx (option) - in conjunction with ATEX Hazardous areas - Ex i ZoneInternational
Zone 21 dust [Ex ia IIIC T125 ...T65 °C Db] EAC (option) Hazardous areasEurasian Economic Community
INMETRO (option) Hazardous areas -Brazil
- Ex n Zone 2 gas [Ex nA IIC T6 ...T1 Gc X] Ex i Zone 0 gas [Ex ia IIC T3 ...T6 Ga]
LogoDescriptionCountry
NEPSI (option) Hazardous areas - Ex i Zone 0 gas [Ex ia IIC T1 ~ T6 Ga]China
KCs - KOSHA (option) Hazardous areas - Ex i Zone 0 gas [Ex ia IIC T4 ...T6] Zone 1 gas [Ex ib IIC T4 ...T6]South Korea
-PESO (option) Hazardous areas Ex i Zone 0 gas [Ex ia IIC T1 ...T6 Ga] Zone 1 mounting to zone 0 gas [Ex ia IIC T1 ...T6 Ga/Gb]India
DNOP - MakNII (option) Hazardous areas Ex i Zone 0 gas [II 1G Ex ia IIC T3 ...T6 Ga] Zone 1 mounting to zone 0 gas [II 1/2G Ex ia IIC T3 ...T6 Ga/Gb]Ukraine
GOST (option) Metrology, measurement technologyRussia
KazInMetr (option) Metrology, measurement technologyKazakhstan
-MTSCHS (option) Permission for commissioningKazakhstan
BelGIM (option) Metrology, measurement technologyBelarus
UkrSEPRO (option) Metrology, measurement technologyUkraine
Uzstandard (option) Metrology, measurement technologyUzbekistan
LogoDescription
SIL 2 Functional safety (only in conjunction with model T32 temperature transmitter)
NAMURNAMUR NE24 Hazardous areas (Ex i)
Connection method
Single elements1 x 2-wire 1 x 3-wire 1 x 4-wire
Dual elements2 x 2-wire 2 x 3-wire 2 x 4-wire 2)
View all (14)
Accuracy class / Range of use of the sensor per EN 60751
ClassSensor construction
Wire-woundThin-film
Class B-196 ...+600 °C-50 ...+500 °C
Class A 3)-100 ...+450 °C-30 ...+300 °C
Class AA 3)-50 ...+250 °C0 ... 150 °C
ModelMaterialCable entry thread sizeIngress protection 1)CapSurface
BSAluminiumM20 x 1.5IP53, IP65Cap with 2 screwsBlue, lacquered 2)
BSZAluminiumM20 x 1.5IP53, IP65Hinged cover with cylinder head screwBlue, lacquered 2)
BSZ-HAluminiumM20 x 1.5IP53, IP65Hinged cover with cylinder head screwBlue, lacquered 2)
ModelDescriptionData sheet
T15Digital transmitter, PC configurableTE 15.01
T32Digital transmitter, HART ® protocolTE 32.04
T53Digital transmitter, FOUNDATION Fieldbus and PROFIBUS ® PATE 53.01
T91.10Analogue transmitter, fixed measuring rangeTE 91.01
Connection headTransmitter model
T15T32T53T91.10
BS----
BSZ----
BSZ-H●●●●
Metal thermowell
Outer diameterWall thickness
Ø Fs
222
152
MaterialAISIApplicableResistance against
No.No.in airSulphurous gasesNitrogen-containing gases with low oxygen contentCarburisation
up to °COxidisingReducing
1.0305-550lowslightmediumslight
1.4571316 Ti800slightslightmediummedium
1.4762-1,200very highhighslightmedium
1.4841310 / 3141,150very slightvery slighthighslight
Material No.Range of applications
1.0305 (St35.8)Tempering furnaces for heat treatment plants, galvanising and tinning plants, carbon-dust-air mixture pipelines in steam power stations
1.0305 enamelled (St35.8 enamelled)Flue-gas desulphurisation plants, babbitt metal, lead and tin smelters
1.4762 X 10 CrAISi 25Combustion exhaust gases, cement and ceramic furnaces, heat treatment plants, annealing furnaces
1.4749 X 18 CrNi 28Flue gas ducts, annealing furnaces
1.4841 X 15 CrNiSi 25-21Combustion chambers, industrial furnaces, petrochemical industry, hot blast stoves, cyanide baths
ThermowellDimensions inmmProcess connection
External ØØ f/f 4i min.E
2222.520G1,1G1½
1515.520G½,G¾,G1
ThermowellDimensions inmm
External ØØ f/f 4C (hole)
2222.570
1515.555
Flange diameterMaterial
1 ½inch, 150 lbs, RFStainless steel 316
1 ½inch, 300 lbs, RFStainless steel 316
2 inch, 150 lbs, RFStainless steel 316
2 inch, 300 lbs, RFStainless steel 316
3 inch, 150 lbs, RFStainless steel 316
3 inch, 300 lbs, RFStainless steel 316
4 inch, 150 lbs, RFStainless steel 316
4 inch, 300 lbs, RFStainless steel 316