TR36 1
TR36
In stock at WIKA
WIKA · Temperature measurement · Family TR

Resistance thermometer

Resistance thermometer, threaded, compact version with Pt100/Pt1000 or 4-20mA transmitter output, for use in machine building, plant construction, and hydraulics.
Range
-50…250 °C
Output
4-20mA · HART
Accuracy
±0.25 K or 0.25 % of set span
Protection
IP65
RoHSCE2.2 test report3.1 inspection certificateDAkkS calibration certificate
Price
From €96
Confirm at order time
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

Resistance thermometers of these series are used as universal thermometers for the measurement of liquid and gaseous media in the range -50 ... +250 °C [-58 ... +482 °F].

They can be used for pressures up to 140 bar [2,030 psi] with 3 mm [0.12 in] protection tube diameters, up to 270 bar [3,916 psi] with 6 mm [0.24 in] protection tube diameters, and up to 400 bar [5,801 psi] with 8 mm [0.31 in] protection tube diameters, depending on the instrument version. All electrical components are protected against splash water and designed to withstand vibration (8 g, depending on instrument version).

Special features

  • Sensor range -50 ... +250 °C [-58 ... +482 °F]
  • Compact design
  • Electrical connection via angular connector DIN EN 175301-803 form A
  • With direct sensor output (Pt100 in 2-, 3- or 4-wire connection) or integrated transmitter
  • Integrated transmitter with 4 ... 20 mA output signal, individually parameterisable with free-of-charge WIKAsoft-TT PC configuration software
Identification
ModelTR36
Product familyTR
SubcategoryThreaded resistance thermometer
Measuring range
Temperature ranges−50…+250 °C · −30…+150 °C · −30…+250 °C · −50…+150 °C
Accuracy
Accuracy class±0.25 K or 0.25 % of set span
Process conditions
Process connection
M12 x 1.5M20 x 1.5G 1/4 BG 3/8 BG 1/2 B1/4 NPT1/2 NPTG¼BG⅜BG½B¼NPT½NPTThreaded (parallel or tapered)Compression fittingWithout process connection
Process temperature−50…+250 °C
Electrical characteristics
Output signal4-20mA · HART · HART (configurable via software)
Power supplyDC 10 ... 30 V
Electrical connectionAngular connector DIN EN 175301-803 form A
Materials
Probe materialStainless steel 1.4571, 1.4571, Stainless steel
Operating environment
Ambient temperature−40…+85 °C
IP ratingIP65
Weight0.45 kg
Certifications and approvals
Certifications
RoHSCE2.2 test report3.1 inspection certificateDAkkS calibration certificate
Additional details
Sensor typePt100
Sensor classA
Probe length100 mm
Probe diameter3 mm
ThermowellNo
Datasheet languagesEN, DE
Tables from datasheet
Measuring element
Type of measuring element
Version 4 ...20mAPt1000 (measuring current < 0.3 mA;self-heating can be ignored)
Version Pt100Pt100 (measuring current 0.1 ... 1.0 mA)
→ For detailed specifications for Pt sensors, see Technical information IN 00.17 at www.wika.com.
Connection method
Version 4 ...20mA2-wire
Version Pt1002-wireThe lead resistance is recorded as an error in the measurement
3-wireWith a cable length of 30 mor longer, measuring deviations can occur
4-wireThe lead resistance can be ignored
Tolerance value of the measuring element 1) per IEC 60751
Version 4 ...20mAClass A
Version Pt100■ Class A ■ Class B at2-wire
Accuracy specifications (4 ... 20 mA version)
Tolerance value of the measuring element 1) per IEC 60751Class A
Measuring deviation of the transmitter per IEC 62828±0.25 K or 0.25 %of the set span (greater value applies)
Total measuring deviation per IEC 62828 2)Measuring deviation of the measuring element + transmitter
Influence of ambient temperature0.1 %of the set measuring span / 10 KT a
Influence of supply voltage±0.025 %of the set measuring span /V (depending on the supply voltage U B )
Influence of load±0.05 %of the set measuring span / 100Ω
LinearisationLinear to temperature per IEC 60751
Output error±0.1% 3) of the set measuring span
Reference conditions
Ambient temperatureT a ref23 °C
Supply voltage U B refDC 24V
Measuring range
Temperature range
Version 4 ...20mAWithout neck tube -30 ...+150 °C [-22 ...+302 °F] With neck tube -30 ...+250 °C [-22 ...+482 °F] 1)
Version Pt100Class AWithout neck tube -30 ...+150 °C [-22 ...+302 °F] With neck tube -30 ...+250 °C [-22 ...+482 °F] 1)
Class BWithout neck tube -50 ...+150 °C [-58 ...+302 °F] With neck tube -50 ...+250 °C [-58 ...+482 °F] 1)
Unit (4 ... 20 mA version)Configurable °C, °F, K
Temperature at the connector (Pt100 version)Max. 85 °C [185 °F]
Measuring span (4 ... 20 mA version)Minimum 20 K, maximum 300 K
Process connection
Type of process connection■ G¼B ■ G⅜B ■ G½B ■ ¼NPT ■ ½NPT ■ M12 x 1.5 ■ M20 x 1.5
Protection tube
Protection tube diameter■ 3 mm[0.12 in] ■ 6 mm[0.24 in] ■ 8 mm[0.31 in]
Insertion length U 1■ 50 mm[1.97 in] ■ 75 mm[2.95 in] 1) ■ 100 mm[3.94 in] 1) ■ 120 mm[4.72 in] 1) ■ 150 mm[5.91 in] 1) ■ 200 mm[7.87 in] 1) ■ 250 mm[9.84 in] 1) ■ 300 mm[11.81 in] 1) ■ 350 mm[13.78 in] 1) ■ 400 mm[15.75 in] 1) Other insertion lengths on
request
Material (wetted)Stainless steel 1.4571
View all (10)
Output signal (4 ... 20 mA version)
Factory configuration
Measuring rangeMeasuring range 0 ... 150 °C [32 ... 302 °F]
Other measuring ranges are adjustable
Current signals for error signallingConfigurable in accordance with NAMUR NE 043 downscale < 3.6 mA(3.5 mA) upscale > 21.0 mA(21.5 mA)
Current value for sensor short-circuitNot configurable in accordance with NAMUR NE 043 downscale ≤ 3.6 mA(3.5 mA)
Communication
Info dataTAG no., description and user message can be stored in transmitter
Configuration and calibration dataPermanently stored
Configuration softwareWIKAsoft-TT → Configuration software (multilingual) as a download from www.wika.com
Voltage supply
Supply voltage U BDC 10 ...30V
Supply voltage inputProtected against reverse polarity
Permissible residual ripple of supply voltage10 %generated by U B < 3 %ripple of the output current
Time response
Switch-on delay, electricalMax. 4 s (time before the first measured value)
Warm-up timeAfter approx. 4 minutes, the instrument will function to the specifications (accuracy) given in the data sheet.
Electrical connection
Connection typeAngular connector DIN EN 175301-803 form A for cables with 6 ...8mm [0.24 ... 0.31 in] diameter, cross-section max. 1.5 mm²
Material
Case material of the connectorPA
Flat gasketVMQ
Operating conditions
Ambient temperature range-40 ...+85 °C [-40 ...+185 °F]
Storage temperature range-40 ...+85 °C [-40 ...+185 °F]
Climate class per IEC 60654-1Cx (-40 ...+85 °C [-40 ...+185 °F], 5 ... 95 %r.h.)
Maximum permissible humidity, condensation100 %r.h., condensation allowed
Maximum operating pressure 1) 2)
For protection tube diameter 3 mm[0.12 in]140 bar [2,030 psi]
For protection tube diameter 6 mm[0.24 in]270 bar [3,916 psi]
For protection tube diameter 8 mm[0.31 in]400 bar [5,801 psi]
Salt fogIEC 60068-2-11
Vibration resistance per IEC 6075110 ... 2,000 Hz, 8 g 1)
Shock resistance per IEC 60068-2-2750 g, 6 ms, 3 axes, 3 directions, three times per direction
Ingress protection (IP code)IP65 per IEC/EN 60529
The stated ingress protection only applies when plugged in using line connectors that have the appropriate ingress protection.
WeightApprox. 0.2 ... 0.7 kg [0.44 ... 1.54 lbs] - depending on version
LogoDescriptionRegion
EU declaration of conformityEuropean Union
Certification typeMeasurement accuracyMaterial certificate
2.2 test reportxx
3.1 inspection certificatexx
DAkkS calibration certificatex-
ModelDescriptionOrder number
Programming unit Model PU-548■ Easy to use ■ LED status display ■ Compact design ■ No further voltage supply needed, neither for the programming unit nor for the transmitter (replaces programming unit model PU-448)14231581
-Adapter cable DIN angular connector for the connection of a resistance thermometer with a DIN EN 175301-803 angular connector form A to the model PU-548 programming unit14005324