WIKA · Temperature measurement · Family TCC
Linear sensor for hot spot detection
Linear sensor for hot spot detection with virtual junction, continuous temperature measurement up to 400 °C, Type K thermocouple conductors, self-restoring.
Range
-223…400 °C
Output
4-20mA · HART
Protection
IP65
RoHSEU declaration of conformityCEEx version possible
Price
On request
Depends on configuration
Description
Unlike a traditional thermocouple which has a hot junction made of a physical union of two conductors, the model TCC creates a virtual junction at the maximum temperature point. With this virtual junction, the sensor is able to detect a maximum temperature along its entire length. It can even detect, in real time, the maximum temperature even if the position of the hot spot changes.
By setting up multiple sensors to cover a large surface area, monitoring of different zones can be achieved to enable localisation of the hot spot.
Linear sensor for hot spot detection, model TCC
Special features
- Continuous temperature measurement over entire length of sensor sheath
- Temperature measurement up to 400 °C [750 °F]
- Type K thermocouple conductors
- Self-restoring
Identification
| Model | TCC |
| Subcategory | Linear sensor for hot spot detection |
Measuring range
| Temperature ranges | +0…+400 °C · −223…+400 °C |
Process conditions
| Process connection | M12 x 1.5½NPTM16 x 1.5M20 x 1.5¾NPT |
| Process temperature | −223…+400 °C |
Electrical characteristics
| Output signal | 4-20mA · HART |
| Electrical connection | Rack-mounting terminals, Ceramic terminal block, Thermoplastic terminal block |
Materials
| Probe material | Stainless steel 316 |
Operating environment
| Ambient temperature | −20…+250 °C |
| IP rating | IP65 |
Certifications and approvals
| Certifications | RoHSEU declaration of conformityCE |
| Explosion protection | Ex version possible |
Additional details
| Sensor type | Type K |
| Probe diameter | 3.5 mm |
| Thermowell | No |
| Datasheet languages | EN |
Tables from datasheet
| Measuring element | 1 1 | |
|---|---|---|
| Type of measuring element | Thermocouple characteristics per IEC 60584-1 or ASTM E230 Type K thermocouple conductors 3 2 | |
| Connection method | ||
| Single element | 1 x 2-wire | Anschlussbelegung Reihenklemmen Thermoelement |
| Single element | Rack-mounting terminals | + - + - + 1 4 2 2 2 1 2 1 3 4 2 1 |
| Single element | Ceramic terminal block | |
| Single element | Thermoplastic terminal block | + - + - |
| Versions of the hot junction | Position of the hot junction | Thermocouple conductors Virtual hot junction Sheath Hot spot |
| Marking of the polarity | Single thermocouple marking per IEC 60584-1 or ASTM E230 |
Sheathed cable
| Design | MIMS cable (sheathed cable) Thermocouple wires embedded in highly compressed ceramic powder | |
|---|---|---|
| Diameter | 3.5 mm±0.5 mm[0.138 in ±0.020 in] | |
| Material | Stainless steel 316 | ■ Up to 850 °C [1,562 °F] ■ Self-reinstatement of normal operating conditions after any hot spot |
| → Other materials on request |
| Model | Material | Cap | Surface | Cable thread size | Ingress protection (max.) 1) IEC/EN 60529 | Dimensions in mm[in] | |
|---|---|---|---|---|---|---|---|
| Field case (Inputs on one side) | Plastic (ABS) | Flat cover with 4 plug screws | Grey | ■ M12 x 1,5 ■ ½NPT ■ M16 x 1,5 | IP65 | 82 x 80 x 55 [3.2 x 3.1 x 2.2] (LxWxH) | |
| Field case (Inputs on one side) | Aluminium | Flat cover with 4 plug screws | Natural finish | ■ M12 x 1.5 ■ ½NPT ■ M16 x 1.5 | IP65 | 80 x 75 x 57 [3.1 x 2.9 x 2.3] (LxWxH) | |
| Field case (Inputs opposite each other) | Plastic (ABS) | Flat cover with 4 plug screws | Grey | ■ M12 x 1.5 ■ ½NPT ■ M16 x 1.5 | IP65 | 82 x 80 x 55 [3.2 x 3.1 x 2.2] (LxWxH) | |
| Field case (Inputs opposite each other) | Aluminium | Flat cover with 4 plug screws | Natural finish | ■ M12 x 1.5 ■ ½NPT ■ M16 x 1.5 | IP65 | 80 x 75 x 57 [3.1 x 2.9 x 2.3] (LxWxH) | |
| 1/4000 | 1/4000 | Aluminium | Screw-on lid | Blue, painted 1) | ■ M20 x 1.5 ■ ½NPT ■ ¾NPT | IP66 2) | - |
| 1/4000 5/6000 | Stainless steel 7/8000 | Screw-on lid 7/8000 DIH50 | Natural finish andere | ■ M20 x 1.5 ■ ½NPT ■ ¾NPT KN4-P Anschlussgehäuse | IP66 2) BVC | - | |
| 7/8000 | Aluminium | Screw-on lid | Blue, painted 1) | ■ M20 x 1.5 ■ ½NPT ■ ¾NPT | IP66 2) | - | |
| 7/8000 | Stainless steel | Screw-on lid | Natural finish | ■ M20 x 1.5 ■ ½NPT ■ ¾NPT | IP66 2) | - | |
| 7/8000 DIH50 | 5/6000 andere Anschlussgehäuse | Aluminium KN4-P | Screw-on lid, with digital temperature display, model DIH50-B BVC | Blue, painted 1) | ■ 2 x M20 x 1.5 ■ 2x½NPT ■ 2x¾NPT | IP66 2) | - |
| 5/6000 | Stainless steel | Screw-on lid, with digital temperature display, model DIH50-B | Natural finish | ■ 2 x M20 x 1.5 ■ 2x½NPT ■ 2x¾NPT | IP66 2) | - | |
| PIH-L | Aluminium | Screw-on lid, flat | Blue lid, painted Grey lower body, painted | ■ ½NPT/ closed ■ M20 x 1.5 / closed ■ 2x½NPT ■ 2 x M20 x 1.5 | IP66 2) | - | |
| PIH-H | Aluminium | Screw-on lid, high | Blue lid, painted | ■ ½NPT ■ M20 x 1.5 ■ 2x½NPT | IP66 2) | - | |
| Grey lower body, painted | ■ 2 x M20 x 1.5 |
Operating conditions
| Ambient temperature | 250 °C [480 °F] |
|---|---|
| Operating temperature | Max. 400 °C [752 °F] 1) |
View all (8)
| Transmitter models | T16.H | T38.H |
|---|---|---|
| Data sheet | TE 16.01 | TE 38.01 |
| Figure | ||
| Output | ||
| 4 ...20mA | x | x |
| HART ® protocol | - | x |
| Minimum requiredTCC measuring string length | 15 m[49.2 ft] | 15 m[49.2 ft] |
| Input | Type K | Type K |
| Explosion protection | Ex version possible |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity | European Union | |
| RoHS directive |
Certificates
| Certificates | ■ 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing) ■ 3.1 inspection certificate per EN 10204 on demand (e.g. material proof for wetted metal parts) |
|---|
| Model | Description | Order number |
|---|---|---|
| Welding stud, M6 x 20, Material: Stainless steel A2-50 | 14767350 | |
| Mounting channel, slotted, 1,500 mmlong, Material: Stainless steel 304 | 14767267 |
Industry
Oil & Gas
Pipeline monitoring
Industry
Chemistry / Pharma
Detection of refractory failure in refractory-lined reactors