Multipoint thermocouple
Description
Multipoint thermocouples are often used for measuring temperature profiles in reactors or fuel depots or for the detection of the so-called 'hotspots'.
The so-called multipoint thermocouple T-Bar design is common for certain vessel designs. In this design, several exchangeable thermocouples are linearly arranged in a T-Bar/pipe design.
The thermocouples are replaceable within the protection tube/flanged primary pressure containment. This design can be provided with a secondary containment option and various neck extensions to suit customer requirements. Connection terminals or temperature transmitters are placed in the connection housing which is either a component of the multipoint thermocouple or can be mounted separately, e.g. on a wall or pipeline.
Special features
- Versions to customer specification
- Secondary containment option
- Exchangeable measuring inserts
- Anchored support
| Model | TC94 |
| Product family | TC |
| Subcategory | Multipoint thermocouple |
| Process connection | Flanges of all major national and international standardsANSI/ASME B16.5EN 1092-1DIN 2527Flanges according to ANSI/ASME B16.5Flanges according to EN 1092-1Flanges according to DIN 2527Custom flangesFlanges according to ASME B16.5 (2" to 4", class 150 to 2500)Flanges according to EN 1092-1 (DN 50 to DN 200, PN 16 to PN 100)Flanges to customer specification |
| Electrical connection | Cable compression fittings according to customer specification |
| Probe material | Stainless steel 316, Stainless steel 316L, Stainless steel 347, Stainless steel 321, Special alloys, Carbon steel |
| Thermowell material | Stainless steel 316, Stainless steel 316L, Stainless steel 347, Stainless steel 321, Special alloys, Carbon steel, Carbon steels |
| Sensor type | thermocouple |
| Probe diameter | 6.35 mm |
| Thermowell | Yes |
| Thermowell form | T-Bar |
| Datasheet languages | EN |
| Standards | Flange design |
|---|---|
| ASME B16.5 | Nominal width: 2 ... 4" Pressure rating: class 150 ... 2,500 |
| EN 1092-1/DIN 2527 | Nominal width:DN 50 ...DN 200 Pressure rating:PN 16 ...PN 100 |