Sapphire-design thermocouple
Description
This high-temperature thermocouple with a gas-tight sapphire protection tube has been specifically developed for use in gasification reactors. Through the monocrystalline structure, the sapphire protects the noble metal of the thermocouple from poisonous toxic media in the aggressive atmosphere of the gasification reactor.
This solution has been used successfully in different reactors worldwide since 1997 under the designation model T-FZV. Hermetically sealed, pressure-tight junctions between the sapphire and metal protection tube, and also a multifold sealing system in the connection housing prevents toxic gases from being able to escape the reactor.
For further approvals, see page 4
Special features
- 3 times longer service life in comparison to purely ceramic protection tubes due to the monocrystalline structure of the sapphire sensor
- High process safety with processes up to 1,700 °C [3,092 °F] and 65 bar [943 psi]
- Reduction of unplanned downtime
- Increased safety through double sealing system against escape of toxic media
- Cost savings through the elimination of a purge system and the repairability of the sensor
| Model | TC84 |
| Product family | TC |
| Subcategory | High-temperature thermocouple with sapphire protection tube |
| Temperature ranges | +0…+1600 °C · +0…+1700 °C |
| Accuracy class | Per IEC 60584-1:2013 |
| Process connection | ASME B16.5EN 1092-1ASME 1.5 ... 4"EN 1092-1 DN40 ... DN100RFLTSTForm B1Form B2Form EForm CFlange |
| Process temperature | +0…+1700 °C |
| Probe material | Sapphire, Ceramic C799, Ceramic C610 |
| Thermowell material | Sapphire, Ceramic, 1.4541, 1.5415, 1.7335, 1.7380, F11, F22, SS321, Ceramic C799, Ceramic C610 |
| Ambient temperature | −40…+195 °C |
| IP rating | IP65 |
| Certifications | RoHSCEEMC EN 61326EACREACH |
| Explosion protection | ATEX Ex ec IIC T1...T6 Gc XIECEx Ex ec IIC T1...T6 GcEAC Ex ec IIC T1...T6 GcCCC Ex ec IIC T1...T6 GcECAS Ex ec IIC T1...T6 Gb XATEX directive Hazardous areas - Ex e Zone 2 gas II 3G Ex ec IIC T1 ...T6 Gc XIECEx (option) Hazardous areas - Ex e Zone 2 gas Ex ec IIC T1 ...T6 GcEAC Hazardous areas - Ex e Zone 2 gas Ex ec IIC T1 ...T6 GcCCC Hazardous areas - Ex e Zone 2 gas Ex ec IIC T1 ...T6 GcECAS Hazardous areas - Ex e Zone 2 gas Ex ec IIC T1 ...T6 Gb XII 3G Ex ec IIC T1 ...T6 Gc XIECEx (option)Ex e Zone 2 gas |
| Sensor type | Type S, Type R, Type B |
| Sensor class | 1, 2 |
| Probe length | 1200 mm |
| Probe diameter | 8 mm |
| Thermowell | Yes |
| Thermowell form | fabricated |
| Datasheet languages | EN, DE |
| Operating temperature | |
|---|---|
| Type S | Max. 1,600 °C [2,912 °F] |
| Type R | Max. 1,600 °C [2,912 °F] |
| Type B | Max. 1,700 °C [3,092 °F] |
| Ambient temperature range | |
| T1 ...T6 | -40 ...+80 °C [-40 ...+176 °F] |
| T1 ...T3 | -40 ...+195 °C [-40 ...+383 °F] |
| Storage temperature range | -40 ...+200 °C [-40 ...+392 °F] |
| Pressure limitation | to 65 bar [943 psi] |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity EMCdirective EN 61326 emission (group 1, class B) and immunity (industrial environments) | European Union |
| Description | Logo | Region | |
|---|---|---|---|
| EU declaration of conformity | European Union | ||
| ATEX directive Hazardous areas - Ex e Zone 2 gas II 3G Ex ec IIC T1 ...T6 Gc X | |||
| IECEx (option) Hazardous areas - Ex e Zone 2 gas Ex ec IIC T1 ...T6 Gc | International | ||
| - | PAC Ukraine Metrology, measurement technology | Ukraine | |
| EAC Hazardous areas - Ex e Zone 2 gas Ex ec IIC T1 ...T6 Gc | Eurasian Economic Com - munity | ||
| CCC Hazardous areas - Ex e Zone 2 gas Ex ec IIC T1 ...T6 Gc | China | ||
| - | ECAS Hazardous areas - Ex e Zone 2 gas Ex ec IIC T1 ...T6 Gb X | United Arab Emirates |
| Certificates | ■ 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, material proof, indication accuracy) ■ 3.1 inspection certificate per EN 10204 (e.g. material proof for wetted metal parts, indication accuracy, calibration certificate) |
|---|---|
| Calibration | ■ Factory calibration certificate ■ DAkkS calibration certificate (traceable and accredited in accordance with ISO/IEC 17025) |
| Recommended calibration interval | 1 year (dependent on conditions of use) |
Couldn't find the answer in the documentation? An engineer will reply within a business day.