AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
TC53 1
TC53
On order
WIKA · Temperature measurement · Family TC

Bayonet thermocouple

Bayonet thermocouple for high-temperature applications up to 1,200 °C, suitable for plastics processing, injection moulding, engines, bearings, pipelines, and vessels.
Range
-40…1260 °C
Protection
IP65
RoHSGOSTMTSCHSBelGIMUkrSEPROUzstandardKazInMetrEACINMETRONEPSIPESOKCs - KOSHADNOP - MakNIICEKCsDNOPKazinMetr[Ex ia IIC T1 ... T6 Ga][Ex ia IIIC T125 ... T65 °C Da][Ex ib IIC T3 ... T6 Ga/Gb][Ex ib IIC T3 ... T6 Gb][Ex ia IIC T3 ~ T6][Ex ia/ib IIC T3 ~ T6]Ex ib IIC T3 ... T6 Ga/GbEx ib IIC T3 ... T6 Gb[II 1G Ex ia IIC T1 ... T6 Ga][II 2G Ex ia IIC T1 ... T6 Gb][II 3G Ex nA IIC T1 ... T6 Gc X][Ex ia IIC T1 ... T6 Ga/Gb][Ex ia IIC T1 ... T6 Gb][Ex ia IIIC T125 ... T65 °C Db][0 Ex ia IIC T3/T4/T5/T6][1 Ex ib IIC T3/T4/T5/T6][Ex nA IIC T6 ... T1][DIP A22 Ta 80 ... 440 °C][Ex ia IIC T3 ... T6 Ga][Ex ib IIIC T125 ... T65 °C Db][Ex ib IIC T3 ~ T6][Ex ia IIC T4 ... T6][Ex ib IIC T4 ... T6][II 1G Ex ia IIC T1 ...T6 Ga][II 2G Ex ia IIC T1 ...T6 Gb][II 3G Ex nA IIC T1 ...T6 Gc X][Ex ia IIC T3 ...T6 Ga][Ex ib IIC T3 ...T6 Ga/Gb][Ex ib IIC T3 ...T6 Gb][Ex ia IIC T4 ...T6][Ex ib IIC T4 ...T6]II 1G Ex ia IIC T1...T6 GaII 1/2G Ex ia IIC T1...T6 Ga/GbII 2G Ex ia IIC T1...T6 GbII 1D Ex ia IIC T125...T65℃ DaII 2D Ex ia IIC T125...T65℃ DbII 3G Ex nA IIC T1...T6 Gc XII 3D Ex tc IIC T440...T80℃ Dc X0 Ex ia IIC T3/T4/T5/T61 Ex ib IIC T3/T4/T5/T6Ex nA IIC T6 ... T1DIP A22 Ta 80 ... 440 °CEx ia IIC T3 ... T6 GaEx ia IIC T125 ... T65 °C DaEx ib IIC T125 ... T65 °C Da/DbEx ia IIC T3 ~ T6Ex ia/lib IIC T3 ~ T6Ex ib IIC T3 ~ T6Ex ia IIC T4 ... T6Ex ib IIC T4 ... T6Ex ia IIC T1 ... T6 Ga
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Special features

  • Sensor ranges up to max. 1,200 °C [2,193 °F]
  • Single and dual thermocouple
  • Good heat transfer through adjustable spring-loading
  • Easy installation and removal, no tools needed
  • Explosion-protected versions
Identification
ModelTC53
Product familyTC
SubcategoryCable thermocouple with bayonet-type probe connection
Measuring range
Temperature ranges−40…+1200 °C · −40…+1000 °C · −40…+750 °C · −40…+900 °C · −40…+350 °C · +0…+1260 °C · +0…+760 °C · +0…+870 °C · +0…+370 °C · −40…+800 °C
Process conditions
Process connection
M10 x 1M14 x 1.5G ¼ BG ⅜ BG 1/4 BG 3/8 B
Process temperature−40…+1200 °C
Electrical characteristics
Electrical connectionFlying leads, connectors (Lemosa, Binder, thermo connectors)
Materials
Probe materialStainless steel
Operating environment
Ambient temperature−60…+150 °C
IP ratingIP65
Certifications and approvals
Certifications
RoHSGOSTMTSCHSBelGIMUkrSEPROUzstandardKazInMetrEACINMETRONEPSIPESOKCs - KOSHADNOP - MakNIICEKCsDNOP
Explosion protection
[Ex ia IIC T1 ... T6 Ga][Ex ia IIIC T125 ... T65 °C Da][Ex ib IIC T3 ... T6 Ga/Gb][Ex ib IIC T3 ... T6 Gb][Ex ia IIC T3 ~ T6][Ex ia/ib IIC T3 ~ T6][II 1G Ex ia IIC T3, T4, T5, T6 Ga]Ex ib IIC T3 ... T6 Ga/GbEx ib IIC T3 ... T6 Gb[II 1G Ex ia IIC T1 ... T6 Ga][II 1/2G Ex ia IIC T1 ... T6 Ga/Gb][II 2G Ex ia IIC T1 ... T6 Gb][II 1D Ex ia IIIC T125 ... T65 °C Da][II 1/2D Ex ia IIIC T125 ... T65 °C Da/Db][II 2D Ex ia IIIC T125 ... T65 °C Db][II 3G Ex nA IIC T1 ... T6 Gc X][II 3D Ex tc IIIC T440 ... T80 °C Dc X][Ex ia IIC T1 ... T6 Ga/Gb][Ex ia IIC T1 ... T6 Gb][Ex ia IIIC T125 ... T65 °C Da/Db][Ex ia IIIC T125 ... T65 °C Db][0 Ex ia IIC T3/T4/T5/T6][1 Ex ib IIC T3/T4/T5/T6][DIP A20 Ta 65 °C/Ta 95 °C/Ta 125 °C][DIP A21 Ta 65 °C/Ta 95 °C/Ta 125 °C][Ex nA IIC T6 ... T1][DIP A22 Ta 80 ... 440 °C][Ex ia IIC T3 ... T6 Ga][Ex ib IIIC T125 ... T65 °C Da/Db][Ex ib IIIC T125 ... T65 °C Db][Ex ib IIC T3 ~ T6][Ex ia IIC T4 ... T6][Ex ib IIC T4 ... T6][II 2G Ex ia IIC T3, T4, T5, T6 Gb][II 1D Ex ia IIIC T65, T95, T125 °C Da][II 2D Ex ib IIIC T125 ... T65 °C Db]Zone 22 dust [DIP A22Ta 80 ... 440 °C]II 1G Ex ia IIC T1...T6 GaII 1/2G Ex ia IIC T1...T6 Ga/GbII 2G Ex ia IIC T1...T6 GbII 1D Ex ia IIC T125...T65℃ DaII 1/2D Ex ia IIC T125...T65℃ Da/DbII 2D Ex ia IIC T125...T65℃ DbII 3G Ex nA IIC T1...T6 Gc XII 3D Ex tc IIC T440...T80℃ Dc X0 Ex ia IIC T3/T4/T5/T61 Ex ib IIC T3/T4/T5/T6DIP A20 Ta 65 °C/Ta 95 °C/Ta 125 °CDIP A21 Ta 65 °C/Ta 95 °C/Ta 125 °CEx nA IIC T6 ... T1DIP A22 Ta 80 ... 440 °CEx ia IIC T3 ... T6 GaEx ia IIC T125 ... T65 °C DaEx ib IIC T125 ... T65 °C Da/DbEx ia IIC T3 ~ T6Ex ia/lib IIC T3 ~ T6Ex ib IIC T3 ~ T6Ex ia IIC T4 ... T6Ex ib IIC T4 ... T6Ex ia IIC T1 ... T6 GaII 1G Ex ia IIC T3, T4, T5, T6 GaII 2G Ex ia IIC T3, T4, T5, T6 GbII 1D Ex ia IIIC T65, T95, T125 °C DaII 2D Ex ib IIIC T125 ... T65 °C Db
Additional details
Sensor typeType K/J/E/N/T
Sensor classClass 1, Class 2
Probe length10 mm
Probe diameter6 mm
ThermowellNo
Datasheet languagesEN, DE
Tables from datasheet
LogoDescriptionCountry
EU declaration of conformity ■ RoHS directiveEuropean Union
- Ex i Zone 0 gas Zone 1 mounting to zone Zone 1 gas Zone 20 dust Zone 21 mounting to zone Zone 21 dust - Ex n Zone 2 gas Zone 22 dust (option) conjunction with ATEX)[II 1G Ex ia IIC T1 ...T6 Ga] [II 1/2G Ex ia IIC T1 ...T6 Ga/Gb] [II 2G Ex ia IIC T1 ...T6 Gb] [II 1D Ex ia IIIC T125 ...T65 °C Da] [II 1/2D Ex ia IIIC T125 ...T65 °C Da/Db] [II 2D Ex ia IIIC T125 ...T65 °C Db] [II 3G Ex nA IIC T1 ...T6 Gc X] [II 3D Ex tc IIIC T440 ...T80 °C Dc X]International
IECEx (in Hazardous areas - Ex i Zone 0 gas Zone 1 mounting to zone Zone 1 gas[Ex ia IIC T1 ...T6 Ga] [Ex ia IIC T1 ...T6 Ga/Gb] [Ex ia IIC T1 ...T6 Gb]
LogoDescriptionCountry
EAC (option) Hazardous areasEurasian Economic Community
Zone 22 dust [DIP A22Ta 80 ... 440 °C] INMETRO (option) Hazardous areas - Ex i Zone 0 gas [Ex ia IIC T3 ...T6 Ga] Zone 1 mounting to zone 0 gas [Ex ib IIC T3 ...T6 Ga/Gb] Zone 1 gas [Ex ib IIC T3 ...T6 Gb] Zone 20 dust [Ex ia IIIC T125 ...T65 °C Da]Brazil
NEPSI (option) Hazardous areas - Ex i Zone 0 gas [Ex ia IIC T3 ~ T6] Zone 1 mounting to zone 0 gas [Ex ia/ib IIC T3 ~ T6]China
KCs - KOSHA (option) Hazardous areas Ex i Zone 0 gas [Ex ia IIC T4 ...T6] Zone 1 gas [Ex ib IIC T4 ...T6]South Korea
-PESO (option) Hazardous areas - Ex i Zone 0 gas [Ex ia IIC T1 ...T6 Ga] Zone 1 mounting to zone 0 gas [Ex ib IIC T3 ...T6 Ga/Gb]India
Zone 1 gas [Ex ib IIC T3 ...T6 Gb] DNOP - MakNII (option) Hazardous areas - Ex i Zone 0 gas [II 1G Ex ia IIC T3, T4, T5, T6 Ga]Ukraine
GOST (option) Metrology, measurement technologyRussia
KazInMetr (option) Metrology, measurement technologyKazakhstan
-MTSCHS (option) Permission for commissioningKazakhstan
BelGIM (option) Metrology, measurement technologyBelarus
UkrSEPRO (option) Metrology, measurement technologyUkraine
Uzstandard (option) Metrology, measurement technologyUzbekistan
TypeOperating temperatures of the thermocouple
IEC 60584-1ASTM E230
Class 2Class 1Standard Special
K-40 ... +1,200 °C-40 ... +1,000 °C0 ... 1,260 °C
J-40 ...+750 °C-40 ...+750 °C0 ... 760 °C
E-40 ...+900 °C-40 ...+800 °C0 ... 870 °C
N-40 ... +1,200 °C-40 ... +1,000 °C0 ... 1,260 °C
T-40 ...+350 °C0 ... 370 °C
CriterionDimensions T inmmØ transition inmm
Probe Ø = transition sleeve Øn/aIdentical to probe
Ø6mm with crimped transition sleeve457
Ø6mm with crimped transition sleeve 2)458
Ø8mm with crimped transition sleeve4510
View all (7)
Probe ØProcess connectionNSNipple boreSpring ØFlatsThread lengthOrder no.
Ø dØ NBØ FDSWi
6M10 x 1126,4614103120914
M14 x 1,5148,4617103366788
G¼B148,4617103118927
G⅜B148,4617113118901
8M14 x 1,5148,4717103366788
G¼B148,4717103118927
G⅜B148,4717113118901
Sensor typeStandardPositiveNegative
KIEC 60584GreenWhite
JIEC 60584BlackWhite
EIEC 60584VioletWhite
TIEC 60584BrownWhite
NIEC 60584PinkWhite
Certification typeMeasuring accuracyMaterial certificate
2.2 Test reportxx