Measuring insert
Description
The measuring inserts for thermocouples described here are designed for installation in a thermometer model TC10-L. Operation without thermowell is appropriate only in special cases. The measuring insert is made of flexible, mineral insulated sheathed cable. The sensor is located in the tip of the measuring insert. This model is spring-loaded to ensure that the measuring insert is firmly pressed down on the thermowell bottom.
The following versions are possible:
- ■ With mounted sleeve to suit inner diameter of the thermowell - ■ Without terminal block - ■ With transmitter
Type and number of sensors, accuracy and connection method can each be selected to suit the respective application.
for further approvals see page 2
Special features
- Sensor ranges from -40 ... +1,200 °C [-40 ... +2,192 °F]
- Made of mineral-insulated sheathed measuring cable
- For all standard thermowell designs
- Spring-loaded design
- Explosion-protected versions
| Model | TC10-K |
| Product family | TC10 |
| Subcategory | Measuring insert for thermocouple |
| Safety integrity level (SIL) | SIL 2 (in combination with model T32.1S transmitter) |
| Ambient temperature | −40…+1200 °C |
| IP rating | IP65 |
| Certifications | RoHSIECExEACINMETCONEPSIKCs - KOSHAPESOGOSTKazInMetrMTSCHSBelGIMUkrSEPROUzstandardEU Declaration of ConformityEMC directive EN 613262.2 test report3.1 inspection certificateDKD/DAkkS calibration certificateEMC EN 61326CEATEX |
| Explosion protection | Ex ia IIC T1...T6 GbEx ib IIC T3...T6 GbEx ib IIC T3 ~ T6Ex ib IIC T4...T6ATEX: II 2G Ex ia IIC T1 ... T6 GbIECEx: Ex iaEAC: Ex ia IIC T1 ... T6 GbINMETRO: 1 Ex ib IIC T3/T4/T5/T6NEPSI: Ex ib IIC T3 ... T6KCs-KOSHA: Ex ib IIC T3 ~ T6PESO: Ex ib IIC T3 ... T6 GbGOSTKazInMetrMTSCHSBelGIMUkrSEPROUzstandardEx d1 Ex ib IIC T3/T4/T5/T6 |
| Datasheet languages | EN, DE |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity ■ EMCdirective 1) EN 61326 emission (group 1, class B) and immunity (industrial application) ■ RoHS directive | European Union | |
| International | ||
| IECEx (option) (in conjunction with ATEX) Hazardous areas - Ex i Zone 1 gas [Ex ia IIC T1 ...T6 Gb] EAC (option) | Eurasian Economic Community | |
| Hazardous areas Ex i Zone 1 gas [1 Ex ib IIC T3/T4/T5/T6] | ||
| INMETCO (option) Hazardous areas Ex i Zone 1 gas [Ex ib IIC T3 ...T6 Gb] | Brazil | |
| NEPSI (option) Hazardous areas Ex i Zone 1 gas [Ex ib IIC T3 ~ T6] | China | |
| KCs - KOSHA (option) Hazardous areas - Ex i Zone 1 gas [Ex ib IIC T4 ...T6] | South Korea | |
| - | PESO (option) Hazardous areas | India |
| GOST (option) | Russia | |
| KazInMetr (option) Metrology, measurement technology | Kazakhstan | |
| - | MTSCHS (option) Permission for commissioning | Kazakhstan |
| BelGIM (option) Metrology, measurement technology | Belarus | |
| UkrSEPRO (option) Metrology, measurement technology | Ukraine | |
| Uzstandard (option) Metrology, measurement technology | Uzbekistan |
| Type | Operating temperatures of the thermocouple | ||
|---|---|---|---|
| IEC 60584-1 | ASTM E230 | ||
| Class 2 | Class 1 | Standard Special | |
| K | -40 ... +1,200 °C | -40 ... +1,000 °C | 0 ... 1,260 °C |
| J | -40 ...+750 °C | -40 ...+750 °C | 0 ... 760 °C |
| E | -40 ...+900 °C | -40 ...+800 °C | 0 ... 870 °C |
| N | -40 ... +1,200 °C | -40 ... +1,000 °C | 0 ... 1,260 °C |
| T | -40 ...+350 °C | 0 ... 370 °C |
| Transmitter (selectable versions) | Model T16 | Model T32 | Model T53 | Model T91.10 |
|---|---|---|---|---|
| Data sheet | TE 16.01 | TE 32.04 | TE 53.01 | TE 91.01 |
| Output | ||||
| ■ 4 ...20mA | x | x | x | |
| ■ HART ® protocol | x | |||
| ■ FOUNDATION™ Fieldbus and PROFIBUS ® PA | x | |||
| Input | ||||
| ■ Thermocouples IEC 60584-1 | K, J, E, N,T | K, J, E, N,T | K, J, E, N,T | K, J,T |
| Explosion protection | Optional | Optional | Standard | - |
| Measuring insert length l 5 inmm | Tolerance inmm |
|---|---|
| 75 ... 825 | +2 0 |
| > 825 | +3 0 |
View all (6)
| Measuring insert diameter Ø d inmm | Index per DIN 43735 | Tolerance inmm | |
|---|---|---|---|
| 3 1) | Standard | 30 | 3 ±0.05 |
| 6 | Standard | 60 | 6 0 -0.1 |
| 8 (6 mmwith sleeve) | Standard | - | 8 0 -0.1 |
| 8 | Standard | 80 | 8 0 -0.1 |
| 1/8 inch (3.17 mm) 1) 1/4 inch (6.35 mm) 3/8 inch (9.53 mm) | Option, on request | - | - |
| Certification type | Measurement accuracy | Material certificate |
|---|---|---|
| 2.2 test report | x | x |
| 3.1 inspection certificate | x | x |
| DKD/DAkkS calibration certificate | x | - |
Couldn't find the answer in the documentation? An engineer will reply within a business day.