AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
TC10-K 1
TC10-K
On order
WIKA · Temperature measurement · Family TC10

Measuring insert

For thermocouple with flameproof enclosure (TC10-L)
Protection
IP65
RoHSIECExEACINMETCONEPSIKCs - KOSHAPESOGOSTKazInMetrMTSCHSBelGIMUkrSEPROUzstandardEU Declaration of ConformityEMC directive EN 613262.2 test report3.1 inspection certificateEMC EN 61326CEATEXEx ia IIC T1...T6 GbEx ib IIC T3...T6 GbEx ib IIC T3 ~ T6Ex ib IIC T4...T6IECEx: Ex iaEAC: Ex ia IIC T1 ... T6 GbINMETRO: 1 Ex ib IIC T3/T4/T5/T6NEPSI: Ex ib IIC T3 ... T6KCs-KOSHA: Ex ib IIC T3 ~ T6PESO: Ex ib IIC T3 ... T6 GbEx d1 Ex ib IIC T3/T4/T5/T6
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The measuring inserts for thermocouples described here are designed for installation in a thermometer model TC10-L. Operation without thermowell is appropriate only in special cases. The measuring insert is made of flexible, mineral insulated sheathed cable. The sensor is located in the tip of the measuring insert. This model is spring-loaded to ensure that the measuring insert is firmly pressed down on the thermowell bottom.

The following versions are possible:

- ■ With mounted sleeve to suit inner diameter of the thermowell - ■ Without terminal block - ■ With transmitter

Type and number of sensors, accuracy and connection method can each be selected to suit the respective application.

for further approvals see page 2

Special features

  • Sensor ranges from -40 ... +1,200 °C [-40 ... +2,192 °F]
  • Made of mineral-insulated sheathed measuring cable
  • For all standard thermowell designs
  • Spring-loaded design
  • Explosion-protected versions
Identification
ModelTC10-K
Product familyTC10
SubcategoryMeasuring insert for thermocouple
Accuracy
Safety integrity level (SIL)SIL 2 (in combination with model T32.1S transmitter)
Operating environment
Ambient temperature−40…+1200 °C
IP ratingIP65
Certifications and approvals
Certifications
RoHSIECExEACINMETCONEPSIKCs - KOSHAPESOGOSTKazInMetrMTSCHSBelGIMUkrSEPROUzstandardEU Declaration of ConformityEMC directive EN 613262.2 test report3.1 inspection certificateDKD/DAkkS calibration certificateEMC EN 61326CEATEX
Explosion protection
Ex ia IIC T1...T6 GbEx ib IIC T3...T6 GbEx ib IIC T3 ~ T6Ex ib IIC T4...T6ATEX: II 2G Ex ia IIC T1 ... T6 GbIECEx: Ex iaEAC: Ex ia IIC T1 ... T6 GbINMETRO: 1 Ex ib IIC T3/T4/T5/T6NEPSI: Ex ib IIC T3 ... T6KCs-KOSHA: Ex ib IIC T3 ~ T6PESO: Ex ib IIC T3 ... T6 GbGOSTKazInMetrMTSCHSBelGIMUkrSEPROUzstandardEx d1 Ex ib IIC T3/T4/T5/T6
Additional details
Datasheet languagesEN, DE
Tables from datasheet
LogoDescriptionCountry
EU declaration of conformity ■ EMCdirective 1) EN 61326 emission (group 1, class B) and immunity (industrial application) ■ RoHS directiveEuropean Union
International
IECEx (option) (in conjunction with ATEX) Hazardous areas - Ex i Zone 1 gas [Ex ia IIC T1 ...T6 Gb] EAC (option)Eurasian Economic Community
Hazardous areas Ex i Zone 1 gas [1 Ex ib IIC T3/T4/T5/T6]
INMETCO (option) Hazardous areas Ex i Zone 1 gas [Ex ib IIC T3 ...T6 Gb]Brazil
NEPSI (option) Hazardous areas Ex i Zone 1 gas [Ex ib IIC T3 ~ T6]China
KCs - KOSHA (option) Hazardous areas - Ex i Zone 1 gas [Ex ib IIC T4 ...T6]South Korea
-PESO (option) Hazardous areasIndia
GOST (option)Russia
KazInMetr (option) Metrology, measurement technologyKazakhstan
-MTSCHS (option) Permission for commissioningKazakhstan
BelGIM (option) Metrology, measurement technologyBelarus
UkrSEPRO (option) Metrology, measurement technologyUkraine
Uzstandard (option) Metrology, measurement technologyUzbekistan
TypeOperating temperatures of the thermocouple
IEC 60584-1ASTM E230
Class 2Class 1Standard Special
K-40 ... +1,200 °C-40 ... +1,000 °C0 ... 1,260 °C
J-40 ...+750 °C-40 ...+750 °C0 ... 760 °C
E-40 ...+900 °C-40 ...+800 °C0 ... 870 °C
N-40 ... +1,200 °C-40 ... +1,000 °C0 ... 1,260 °C
T-40 ...+350 °C0 ... 370 °C
Output signal 4 ... 20 mA, HART ® protocol, FOUNDATION™ Fieldbus and PROFIBUS ® PA
Transmitter (selectable versions)Model T16Model T32Model T53Model T91.10
Data sheetTE 16.01TE 32.04TE 53.01TE 91.01
Output
■ 4 ...20mAxxx
■ HART ® protocolx
■ FOUNDATION™ Fieldbus and PROFIBUS ® PAx
Input
■ Thermocouples IEC 60584-1K, J, E, N,TK, J, E, N,TK, J, E, N,TK, J,T
Explosion protectionOptionalOptionalStandard-
Measuring insert length l 5 inmmTolerance inmm
75 ... 825+2 0
> 825+3 0
View all (6)
Measuring insert diameter Ø d inmmIndex per DIN 43735Tolerance inmm
3 1)Standard303 ±0.05
6Standard606 0 -0.1
8 (6 mmwith sleeve)Standard-8 0 -0.1
8Standard808 0 -0.1
1/8 inch (3.17 mm) 1) 1/4 inch (6.35 mm) 3/8 inch (9.53 mm)Option, on request--
Certification typeMeasurement accuracyMaterial certificate
2.2 test reportxx
3.1 inspection certificatexx
DKD/DAkkS calibration certificatex-