AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
TC10-F 1
TC10-F
On order
WIKA · Temperature measurement · Family TC10

Flanged thermocouple

Flanged thermocouple with protection tube for industrial applications in chemical, petrochemical, energy, and food industries.
Range
-40…1200 °C
Output
4-20mA · HART
Protection
IP65
RoHSGOSTKazInMetrMTSCHSBelGIMUkrSEPROUzstandardNAMUREMCNAMUR NE 024CEATEXIECExEACEx UkraineINMETROCCCKCs-KOSHAPESOEx ia IIIC T125 ... T65 °C DaEx ia IIIC T125 ... T65 °C Da/DbII 1G Ex ia IIC T1 ... T6 GaII 2G Ex ia IIC T1 ... T6 GbII 2G Ex eb IIC T1 ... T6 GbII 3G Ex ec IIC T1 ... T6 Gc XII 2D Ex tb IIIC TX °C DbII 3D Ex tc IIIC TX °C Dc XII 3G Ex nA IIC T1 ... T6 Gc XEx ia IIC T1 ... T6 GaEx ia IIC T1 ... T6 Ga/GbEx ia IIC T1 ... T6 GbEx ia IIIC T125 ... T65 °C Db0Ex ia IIC T6 ... T1 Ga X1Ex ia IIC T6 ... T1 Gb XEx ia IIIC T80…T440 °C Da XEx ia IIIC T80…T440 °C Db X2Ex nA IIC T6 ... T1 Gc XEx ia IIC T3 ... T6 GaEx ia IIC T3 ... T6 Ga/GbEx iaD 20 T65/T95/T125°CEx iaD 21 T65/T95/T125°CEx iaD 20/21 T65/T95/T125°CEx nA IIC T1 ~ T6 GcEx ia IIC T4 ... T6Ex ib IIC T4 ... T6ATEX Ex i Zone 0,1,2ATEX Ex e Zone 1,2ATEX Ex nA Zone 2ATEX Ex ia IIIC T125...T65 °C DbIECEx (in conjunction with ATEX)INMETRO Ex ia IIC T3...T6 Ga/GbCCC Ex ia IIC T1~T6 GbCCC Ex ia IIC T1~T6 Ga/GbCCC Ex ic IIC T1~T6 GcCCC Ex iaD 20 T65/T95/T125°CCCC Ex iaD 21 T65/T95/T125°CKCs - KOSHA Ex ib IIC T4...T6PESO Ex ia IIC T1...T6 Ga/GbPESO Ex ia IIC T1...T6 GbEx ia IIC T1...T6 GaEx ia IIC T1...T6 Ga/GbEx ia IIC T1...T6 GbEx ia IIIC T125...T65 °C DaEx ia IIIC T125...T65 °C Da/DbEx ia IIIC T125...T65 °C DbEx eb IIC T1...T6 GbEx ec IIC T1...T6 Gc XEx tb IIIC TX °C DbEx tc IIIC TX °C Dc XEx nA IIC T6...T1 Gc X
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

Thermocouples of this series are designed for fitting into vessels and pipelines. Standard flanges to DIN EN or ASME are available.

These temperature sensors are suitable for liquid and gaseous media under moderate mechanical load. The protection tube is all welded and screwed into the connection head. Stainless steel protection tubes are suitable for normal chemical conditions. Coating is recommended as an optional extra with chemically aggressive media, or solid wear-resistant coating for abrasive media.

The interchangeable measuring insert can be removed without taking out the complete sensor from the plant. This enables inspection, measuring equipment monitoring or, when servicing is necessary, replacement while the plant is running. The choice of standard lengths assists with short delivery times and the possibility of stocking spare parts.

Special features

  • Sensor ranges from -40 ... +1,200 °C [-40 ... +2,192 °F]
  • With integrated fabricated protection tube
  • Spring-loaded measuring insert (replaceable)
  • Explosion-protected versions are available for many approval types (see data sheet page 2)
Configurator · Step by step

Build a TC10-F for your task

The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.

Step 1 of 3
Configuration structure· click a highlighted segment to jump to that parameter
Your configuration
  • Electrical approvalWithout
  • Ignition protection typeWithout
  • ZoneWithout
  • Thermocouple typeType K
  • Number of thermocouplesSingle thermocouple
  • Accuracy class of the sensorClass 2, IEC 60584
  • Validity limits of class accuracy-40…+1200 °C
  • Hot junctionUngrounded
  • Head / housingBSZ, Aluminum, ball shaped, flip-top
  • Cable entryStandard cable gland for für A-/B-/J- heads
  • Thread size cable entryM20 x 1.5
  • TransmitterWithout (terminal block)
  • Transmitter detailsWithout
  • Connection to neck tubeM24 x 1,5
  • Protection tubeStraight, flange, form 2F DIN 43772
  • Protection tube materialStainless steel 1.4571
  • Protection tube diameter9x1 mm
  • Flange sizeEN 1092-1 DN 25
  • Pressure rating—
  • Flange face—
  • Insertion length [A]—
  • Neck length [MH/N]65
  • Mechanical requirementsWithout
  • CertificatesWithout
AI suggestion by parameters

Finish your configuration

Select every option to submit the request.

Send request