Single point load cell
Description
The model F4885 single point load cells are a range of aluminium single point load cells suitable for a wide range of applications. Thanks to their standardised geometry and simple design, they can be easily installed in all types of scales.
The model F4885 load cells are adapted to the special requirements of checkweighers and feature a particularly short settling time, so that the weight of the goods being recorded can be determined as quickly as possible.
The load cells are also suitable for use in sectors such as industry, commerce, medicine and research.
Load cell, model F4885
The model F4885 single point load cells also feature high accuracy and react quickly. They are also insensitive to lateral and corner loading.
The load cells are easy to handle due to their simple force introduction. This is made perpendicular to the geometry.
Special features
- Measuring ranges 0 ... 1 kg to 0 ... 200 kg [0 ... 2.2 lbs to 0 ... 441 lbs]
- Load cell made from aluminium
- High accuracy (6-wire connection), react quickly, low settling time
- Insensitive to lateral and corner load
- Simple design, easy installation
| Model | F4885 |
| Product family | F488 |
| Subcategory | Single point |
| Force ranges | 0…1 kg · 0…3 kg · 0…5 kg · 0…7 kg · 0…10 kg · 0…15 kg · 0…20 kg · 0…75 kg · 0…100 kg · 0…150 kg · 0…200 kg · 0…2.2 lbf · 0…7 lbf · 0…11 lbf · 0…15 lbf · 0…22 lbf · 0…33 lbf · 0…44 lbf · 0…165 lbf · 0…220 lbf · 0…331 lbf · 0…441 lbf · 0…50 kg · 0…110 lbf · 1…200 kg · 2.2…441 lbf |
| Accuracy class | ±0.02 % Fnom |
| Process temperature | −10…+40 °C |
| Mounting type | Single-point |
| Output signal | 2.0 ±0.2 mV/V |
| Cell material | Aluminium |
| Ambient temperature | −20…+65 °C |
| IP rating | IP67 |
| Weight | 0.5 kg |
| Certifications | RoHSUKCAEAC |
| Overload protection | 150 % |
| Cable length | 3 m |
| Datasheet languages | EN, DE |
| Model F4885 | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rated load F nom kg | 1 | 3 | 5 | 7 | 10 | 15 | 20 | 75 | 100 | 150 | 200 | |
| Rated load F nom lbs | 2.2 | 7 | 11 | 15 | 22 | 33 | 44 | 165 | 220 | 331 | 441 | |
| Relative linearity error d lin 1) | ±0.02%F nom | |||||||||||
| Relative creep, 30 min. | ±0.02%F nom | |||||||||||
| Relative reversibility error v | ±0.02%F nom | |||||||||||
| Relative deviation of zero signal d S,0 | ±5%F nom | |||||||||||
| Temperature effect on the zero signalTK 0 | ≤ ±0.014 %/10 K | |||||||||||
| Temperature effect on the characteristic value TK C | ≤ ±0.02 %/10 K | |||||||||||
| Force limit F L | 150%F nom | |||||||||||
| Breaking force F B | 300%F nom | |||||||||||
| Material of the measuring body | Aluminium | |||||||||||
| Rated temperature range B T;nom | -10 …+40 °C [14 ... 104 °F] | |||||||||||
| Operating temperature range B T, G | -20 …+65 °C [-4 ... 149 °F] | |||||||||||
| Input resistance R e | 410 ±20Ω | |||||||||||
| Output resistance R a | 350 ±5Ω | |||||||||||
| Insulation resistance R is | ≥ 2,000 MΩ/DC 100V | |||||||||||
| Output signal (rated characteristic value) C nom | 2.0 ±0.2 mV/V | |||||||||||
| Electrical connection | Measuring cable ∅5x3,000 mm[∅0.197 x 118 in] | |||||||||||
| Supply voltage U B, nom | DC 5 ...10V (max. 15 V) | |||||||||||
| Ingress protection (per IEC/EN 60529) | IP67 | |||||||||||
| Platform size | 450 x 450 mm[17.72 x 17.72 in] | |||||||||||
| Weight | 0.5 kg [1.1 lbs] |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity RoHS directive | European Union | |
| UKCA RoHS directive | United Kingdom |
| Logo | Description | Region |
|---|---|---|
| EAC | Eurasian Economic Community |
| A | B | C | D | E | G | H | I | J | K | L | M | N |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.54 | 0.04 | 0.35 | 1.34 | 0.04 | 1.54 | 1 | 5.91 | 1.38 | 7.52 | 118 ±5.91 | 39.21 | 0.24 |
View all (5)
| Supply voltage+ | Exc+ | Red |
|---|---|---|
| Supply voltage- | Exc- | Black |
| Signal+ | Sig+ | Green |
| Signal- | Sig- | White |
| Sensor+ | Sen+ | Blue |
| Sensor- | Sen- | Yellow |
| Shield | Shield | Yellow-Green |