Single point load cell
Description
The model F4883 single point load cells are a range of aluminium single point load cells suitable for a wide range of applications. Thanks to their standardised geometry and simple design, they can be easily installed in all types of scales.
The model F4883 load cells are adapted to the special requirements of checkweighers and feature a particularly short settling time, so that the weight of the goods being recorded can be determined as quickly as possible.
The load cells are also suitable for use in sectors such as industry, commerce, medicine and research.
Load cell, model F4883
The model F4883 single point load cells also feature high accuracy and react quickly . They are also insensitive to lateral and corner loading.
The load cells are easy to handle due to their simple force introduction. This is made perpendicular to the geometry.
Special features
- Measuring ranges 0 ... 8 kg to 0 ... 300 kg [0 ... 18 lbs to 0 ... 661 lbs]
- Load cell made from aluminium
- High accuracy, react quickly, low settling time
- Insensitive to lateral and corner load
- Simple design, easy installation
Build a SPP-F4883 for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
- ModelF4883 Single point load cell aluminium 0 ... 8 kg to 0 ... 300 kg
- Force directioncompression
- Unitskg
- Rated force/Rated load—
- Relative linearity error±0.02% Fnom
- Output signal2.0 ±0.2 mV/V
- Electrical connectionCable output, free wires
- Cable length3 m
- Cable diameterØ5 mm
Finish your configuration
Select every option to submit the request.
| Model | F4883 |
| Subcategory | Single point |
| Force ranges | 0…8 kg · 0…15 kg · 0…20 kg · 0…50 kg · 0…100 kg · 0…200 kg · 0…300 kg · 0…18 lbf · 0…33 lbf · 0…44 lbf · 0…110 lbf · 0…220 lbf · 0…441 lbf · 0…661 lbf |
| Accuracy class | ±0.02 % Fnom |
| Process temperature | −10…+40 °C |
| Mounting type | Single-point |
| Output signal | 2.0 ±0.2 mV/V |
| Cell material | Aluminium |
| Ambient temperature | −20…+65 °C |
| IP rating | IP66 |
| Weight | 0.6 kg |
| Certifications | EACRoHSUKCA |
| Overload protection | 150 % |
| Cable length | 3 m |
| Datasheet languages | EN |
| Model F4883 | |||||||
|---|---|---|---|---|---|---|---|
| Rated load F nom kg | 8 | 15 | 20 | 50 | 100 | 200 | 300 |
| Rated load F nom lbs | 18 | 33 | 44 | 110 | 220 | 441 | 661 |
| Relative linearity error din lin 1) | ±0.02%F nom | ||||||
| Relative creep, 30 min. | ±0.02%F nom | ||||||
| Relative reversibility error v | ±0.02%F nom | ||||||
| Relative deviation of zero signal d S,0 | ±5%F nom | ||||||
| Temperature effect on zero signalTK 0 | ≤ ±0.014 %/10 K | ||||||
| Temperature effect on characteristic value TK C | ≤ ±0.02 %/10 K | ||||||
| Force limit F L | 150%F nom | ||||||
| Breaking force F B | 200%F nom | ||||||
| Material of the measuring body | Aluminium | ||||||
| Rated temperature range B T;nom | -10 ...+40 °C [14 ... 104 °F] | ||||||
| Operating temperature range B T, G | -20 ...+65 °C [-4 ... 149 °F] | ||||||
| Input resistance R e | 410 ±10Ω | ||||||
| Output resistance R a | 350 ±5Ω | ||||||
| Insulation resistance R is | ≥ 5,000 MΩ/DC 100V | ||||||
| Output signal (rated characteristic value) C nom | 2.0 ±0.2 mV/V | ||||||
| Electrical connection | Measuring cable ∅5x3,000 mm[∅0.2 x 118 in] | ||||||
| Supply voltage U B, nom | DC 5 ...10V (max. 15 V) | ||||||
| Ingress protection (per IEC/EN 60529) | IP66 | ||||||
| Platform size | 600 x 500 mm[23.62 x 19.69 in] | ||||||
| Weight | 0.6 kg [1.32 lbs] |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity RoHS directive | European Union | |
| UKCA RoHS directive | United Kingdom |
| Logo | Description | Region |
|---|---|---|
| EAC | Eurasian Economic Community |
| Supply voltage+ | Exc+ | Red |
|---|---|---|
| Supply voltage- | Exc- | Green |
| Signal+ | Sig+ | Black |
| Signal- | Sig- | White |
| Shield | Shield | Yellow-green |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →2 standard articles of family F4883
If you know the code — pick directly. If not — use the configurator in mode “01”.