Shear beam
Description
Shear beams are suitable for static and dynamic measuring requirements. They serve for determining shear forces in diverse fields of application.
These shear beams are used in industrial weighing and laboratory technology, and also in the process industry.
The F3201 shear beams are made of stainless steel, whose properties are particularly suitable for the fields of application in scales, laboratory technology and stage construction. An mV/V signal is provided as the output signal.
Shear beam, model F3201
Special features
- Measuring ranges 0 ... 500 to 0 ... 2,000 kg
- 3,000 intervals per OIML R60 Class C
- Stainless steel, hermetically sealed and welded, Ingress protection: IP68 and IP69K
- High long-term stability
- High side load tolerance
Build a SPP-F3201 for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
- ModelF3201 Shear beam, shear forces up to 2,000 kg
- Force directiontension/compression
- Rated force/Rated load—
- Relative linearity error0.017% Fnom
- Output signal2.0 mV/V
- Electrical connectionCable output, free wires
- Cable length5 m
- Cable diameterØ6 mm
Finish your configuration
Select every option to submit the request.
| Model | F3201 |
| Subcategory | Shear beam |
| Force ranges | 0…500 kg · 0…750 kg · 0…1000 kg · 0…2000 kg |
| Accuracy class | OIML R60 Class C |
| Process temperature | −10…+40 °C |
| Mounting type | Shear-beam |
| Output signal | 2.0 mV/V |
| Cell material | Stainless steel |
| Ambient temperature | −30…+70 °C |
| IP rating | IP68/IP69K |
| Weight | 0.9 kg |
| Certifications | RoHSOIML R60 Class CEU declaration of conformityCEOIML |
| Overload protection | 150 % |
| Cable length | 5 m |
| Datasheet languages | EN |
| Model F3201 | |
|---|---|
| Rated load F nom kg | 500, 750, 1,000, 2,000 |
| Relative linearity error d lin | 0.017%F nom |
| Accuracy class | 3,000 intervals per OIML R60 Class C |
| Relative creep, 30 min. | < ±0.016 %Fnom |
| Relative reversibility error v | ±0.015 %Fnom |
| Temperature effect on zero signalTK 0 | ≤ ±0.012 %/10 K |
| Temperature effect on characteristic value TK C | ≤ ±0.02 %/10 K |
| Force limit F L | 150%F nom |
| Breaking force F B | 200%F nom |
| Material of the measuring body | Stainless steel |
| Rated temperature range B T, nom | -10 …+40 °C |
| Operating temperature range B T, G | -30 …+70 °C |
| Input resistance R e | 400 ±20 Ω |
| Output resistance R a | 350 ±3 Ω |
| Insulation resistance R is | ≥ 5,000MΩ |
| Output signal (rated characteristic value ) C nom | 2.0 mV/V |
| Electrical connection | Measuring cable∅6x5m |
| Excitation voltage B U, nom | DC 10V ...15V |
| Ingress protection (per IEC/EN 60529) | IP68 and IP69K |
| Weight | 0.9 kg |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity | European Union | |
| International Organization of Legal Metrology | International |
| Excitation voltage (Exc+) | Green |
|---|---|
| Excitation voltage (Exc-) | Black |
| Signal (Sig+) | Red |
| Signal (Sig-) | White |
| Sense (+) | Blue |
| Sense (-) | Yellow |
| Shield | Shield |
| Rated load | Dimensions inmm | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| in kg | L | L1 | L2 | A | A1 | A2 | B | B1 | C | C1 | H | H1 | H2 | ∅G | ∅E |
| 500 / 750 / 1,000 / 2,000 | 168 | 15 | 136 | 100 | 15 | 70 | 100 | 70 | 100 | 70 | 94 | 20 | 20 | 13.5 | 11 |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →4 standard articles of family F3201
If you know the code — pick directly. If not — use the configurator in mode “01”.