WIKA · Force measurement · Family F2812
Tension/compression force transducer
Tension/compression force transducer with measuring ranges from 0 ... 50 N to 0 ... 1,000 N, stainless steel construction, IP65 protection, suitable for static and dynamic force measurement in industrial applications.
Range
0…1000 N
Output
2.0 ±0.2 mV/V
Accuracy
±0.5 % Fnom
Protection
IP65
CERoHSEACEU declaration of conformityEMC directiveRoHS directiveEAC (option)
Price
On request
Depends on configuration
Description
The tension/compression force transducers are suitable for static and dynamic measuring requirements in the direct force flow. They serve for determining tension and compression forces in diverse application areas.
Force transducers of this series are used in weighing technology and also in numerous industrial applications where high accuracy, simple installation with force introduction via the two female threads, as well as an inexpensive price play a key role.
Tension/compression force transducer, model F2812
Special features
- Measuring ranges 0 ... 50 N up to 0 ... 1,000 N
- Ultra compact design
- Corrosion-resistant stainless steel design
- Protection IP65
Identification
| Model | F2812 |
| Subcategory | Tension/compression force transducer |
Measuring range
| Force ranges | 0…50 N · 0…100 N · 0…150 N · 0…200 N · 0…300 N · 0…500 N · 0…600 N · 0…1000 N |
Accuracy
| Accuracy class | ±0.5 % Fnom |
Process conditions
| Process temperature | −10…+40 °C |
| Mounting type | Tension, compression |
Electrical characteristics
| Output signal | 2.0 ±0.2 mV/V |
Materials
| Cell material | Stainless steel |
Operating environment
| Ambient temperature | −20…+80 °C |
| IP rating | IP65 |
| Weight | 0.1 kg |
Certifications and approvals
| Certifications | CERoHSEACEU declaration of conformityEMC directiveRoHS directiveEAC (option) |
Additional details
| Overload protection | 120 % |
| Cable length | 3 m |
| Datasheet languages | EN |
Tables from datasheet
| Model F2812 | |
|---|---|
| Rated force F nom N | 50 / 100 / 150 / 200 / 300 / 500 / 600 / 1,000 |
| Relative linearity error din lin 1) | ±0.5%F nom |
| Relative reversibility error v | ±0.5%F nom |
| Relative repeatability error in unchanged mounting position b rg | ±0.25%F nom |
| Relative deviation of zero signal d S,0 | ±2%F nom |
| Temperature effect on zero signalTK 0 | ≤ ±0.2 %/ 10 K |
| Temperature effect on characteristic value TK C | ≤ ±0.2 %/ 10 K |
| Force limit F L | 120%F nom |
| Breaking force F B | 200%F nom |
| Material of the measuring body | Stainless steel |
| Rated temperature range B T, nom | -10 ...+40 °C |
| Operating temperature range B T, G | -20 ...+80 °C |
| Input resistance R e | 700 ±30Ω |
| Output resistance R a | 700 ±5Ω |
| Insulation resistance R is | ≥ 5,000 MΩ/DC 100V |
| Output signal (rated characteristic value) C nom | 2.0 ±0.2 mV/V |
| Electrical connection | Measuring cable ∅3x3,000mm |
| Voltage supply | |
| Standard | DC 5 ...10V |
| Option | DC 12 …28Vintegrated or cable amplifier 0 (4) ...20mA DC 0 ...10V DC 0 ...5V |
| Ingress protection (per IEC/EN 60529) | IP65 |
| Weight in kg | 0.1 |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity | European Union | |
| EMCdirective | ||
| RoHS directive | ||
| EAC (option) | Eurasian Economic Community | |
| EMCdirective |
| Rated force in N | M |
|---|---|
| 5 / 100 / 150 / 200 / 300 / 500 | M5 |
| 600 / 1,000 | M6 |
Electrical connection
| Excitation voltage (+) | Red |
|---|---|
| Excitation voltage (-) | Black |
| Signal (+) | Green |
| Signal (-) | White |
| Shield | Shield |
Industry
Machinery
Tension/compression force testing · Tank weighing
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →All variants · Article table
1 standard articles of family F2812
If you know the code — pick directly. If not — use the configurator in mode “01”.
Stock:
SKUConfigurationPriceStockAction
Showing 1 of 1. Price on request — an engineer will quote your configuration.