AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
F2812 1
F2812
On order
WIKA · Force measurement · Family F2812

Tension/compression force transducer

Tension/compression force transducer with measuring ranges from 0 ... 50 N to 0 ... 1,000 N, stainless steel construction, IP65 protection, suitable for static and dynamic force measurement in industrial applications.
Range
0…1000 N
Output
2.0 ±0.2 mV/V
Accuracy
±0.5 % Fnom
Protection
IP65
CERoHSEACEU declaration of conformityEMC directiveRoHS directiveEAC (option)
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The tension/compression force transducers are suitable for static and dynamic measuring requirements in the direct force flow. They serve for determining tension and compression forces in diverse application areas.

Force transducers of this series are used in weighing technology and also in numerous industrial applications where high accuracy, simple installation with force introduction via the two female threads, as well as an inexpensive price play a key role.

Tension/compression force transducer, model F2812

Special features

  • Measuring ranges 0 ... 50 N up to 0 ... 1,000 N
  • Ultra compact design
  • Corrosion-resistant stainless steel design
  • Protection IP65
Identification
ModelF2812
SubcategoryTension/compression force transducer
Measuring range
Force ranges0…50 N · 0…100 N · 0…150 N · 0…200 N · 0…300 N · 0…500 N · 0…600 N · 0…1000 N
Accuracy
Accuracy class±0.5 % Fnom
Process conditions
Process temperature−10…+40 °C
Mounting typeTension, compression
Electrical characteristics
Output signal2.0 ±0.2 mV/V
Materials
Cell materialStainless steel
Operating environment
Ambient temperature−20…+80 °C
IP ratingIP65
Weight0.1 kg
Certifications and approvals
Certifications
CERoHSEACEU declaration of conformityEMC directiveRoHS directiveEAC (option)
Additional details
Overload protection120 %
Cable length3 m
Datasheet languagesEN
Tables from datasheet
Model F2812
Rated force F nom N50 / 100 / 150 / 200 / 300 / 500 / 600 / 1,000
Relative linearity error din lin 1)±0.5%F nom
Relative reversibility error v±0.5%F nom
Relative repeatability error in unchanged mounting position b rg±0.25%F nom
Relative deviation of zero signal d S,0±2%F nom
Temperature effect on zero signalTK 0≤ ±0.2 %/ 10 K
Temperature effect on characteristic value TK C≤ ±0.2 %/ 10 K
Force limit F L120%F nom
Breaking force F B200%F nom
Material of the measuring bodyStainless steel
Rated temperature range B T, nom-10 ...+40 °C
Operating temperature range B T, G-20 ...+80 °C
Input resistance R e700 ±30Ω
Output resistance R a700 ±5Ω
Insulation resistance R is≥ 5,000 MΩ/DC 100V
Output signal (rated characteristic value) C nom2.0 ±0.2 mV/V
Electrical connectionMeasuring cable ∅3x3,000mm
Voltage supply
StandardDC 5 ...10V
OptionDC 12 …28Vintegrated or cable amplifier 0 (4) ...20mA DC 0 ...10V DC 0 ...5V
Ingress protection (per IEC/EN 60529)IP65
Weight in kg0.1
LogoDescriptionRegion
EU declaration of conformityEuropean Union
EMCdirective
RoHS directive
EAC (option)Eurasian Economic Community
EMCdirective
Rated force in NM
5 / 100 / 150 / 200 / 300 / 500M5
600 / 1,000M6
Electrical connection
Excitation voltage (+)Red
Excitation voltage (-)Black
Signal (+)Green
Signal (-)White
ShieldShield