Suspended float switch
Description
Suspended float switches are attached to a highly flexible cable hanging from above and contain a micro switch, which is potted and enclosed, shock and fracture-proof, in a double-chamber system. When the float body is immersed in a liquid, the float bulb tips and triggers the micro switch.
With the MS1 model range, a stabilisation weight is also built in, so that this switch is also suited for greater solids contents.
for further approvals see page 3
Fig. left: Model SLS-M2
Fig. centre: Model SLS-MS1
Fig. right: Model SLS-MS1-Ex
One suspended float switch is required for each switch point. The contact is designed as a change-over contact, so that it can be configured as a high alarm as well as a low alarm.
Through the patented, centrically mounted micro switch, the suspended float switch can switch in any direction, and not dependent on the direction in which the switch tips.
Special features
- For waste water, sewage and heavily soiled liquids
- Environmentally friendly, mercury- and lead-free
- PP housing
- High mechanical and electrical durability of micro-switch
- Suitable for use in hazardous areas Ex zone 0, 1 and 2
| Model | SLS-M2 |
| Product family | SLS |
| Subcategory | float switch |
| Process temperature | −20…+80 °C |
| Measurement technology | float |
| Output signal | 1 ... 100 mA, 4 ... 40 V · 2 A, 250 V · 5 A, 250 V · 5 A, 125 V · change-over contact |
| Electrical connection | Cable: TPK/PVC, orange; TPK/PVC, blue; SJOW 3/18 AWG |
| Wetted parts material | PP, PP PRE-ELEC (anti-static), PP PRE-ELEC, PP UL94 V0, TPK/PVC |
| Ambient temperature | −20…+80 °C |
| IP rating | IP68 |
| Certifications | RoHSATEXIECExLow Voltage DirectiveCEcETLusUL |
| Explosion protection | II 1G Ex ia IIC T6 SEV 13 ATEX 0102 IECEx SEV 13.0001SEV 13 ATEX 0102 II 1G Ex ia IIC T6IECExSEV13.0001 |
| Datasheet languages | EN, DE |
| Specifications | Model SLS-M2 | Model SLS-MS1 | Model SLS-MS1-Ex | Model SLS-MS1-UL | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Medium density | 950 ... 1,050 kg/m³ | 950 ... 1,050 kg/m³ | 950 ... 1,050 kg/m³ | 952 ... 1,050 kg/m³ | |||||||
| Maximum temperature | 80 °C | 80 °C | 80 °C 60 | °C | |||||||
| Switching power | 2 A, 250V | 5 A, 250V | 1 ... 100 mA, 4 ...40V | 5 A, 125V | |||||||
| Case | PP | PP | PP PRE-ELEC (anti-static) | PP UL94V0 | |||||||
| Colour | Orange | Orange | Black | Black | |||||||
| Ingress protection | IP68 | IP68 | IP68 | IP68 | |||||||
| Cable | TPK/PVC, orange | TPK/PVC, orange | TPK/PVC, blue | SJOW 3/18AWG | |||||||
| Wire cross-section | 3 x 0.5 mm² | 3 x 0.75 mm² | 4G 0.75 mm² | 3/18AWG | |||||||
| Cable length | 5m | 10m | 20m | 5m | 10m | 20m | 5m | 10m | 20m | 15 ft | 65 ft |
| Order number | 006109 | 006110 | 006111 | 006115 | 006116 | 112391 | 010924 | 006119 | 006121 | 125290 | 125291 |
| Approval | - | - | SEV 13 ATEX 0102 II 1G Ex ia IIC T6 | cETLus 4004472 UL 508, CSA C22.2 |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity ■ Low voltage directive ■ RoHS directive | European Union | |
| ■ ATEX directive (only model SLS-MS1-Ex) Hazardous areas | ||
| IECEx (only model SLS-MS1-Ex) Hazardous areas | International | |
| ETL (only model SLS-MS1-UL) Safety (industrial control units and flammability for plastics ) Tested according to UL 94 and UL 508 standard | USA |