WIKA · Pressure measurement · Family R-1
Pressure sensor
Pressure transmitter for heating and refrigeration applications with robust design, suitable for flammable refrigerants and extreme conditions.
Range
-1…160 bar
Output
4-20mA · 0-10V
Accuracy
0.5 % BFSL
Protection
IP67
CERoHSEACULCRNUkrSEPRO
Price
On request
Depends on configuration
Special features
- Durable and maintenance-free
- Stable measurement in variable conditions
- Best possible condensation tightness
- Safe handling of flammable refrigerants
- Greatest possible delivery reliability with WIKA as an experienced OEM partner
Configurator · Step by step
Build a R-1 for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
Step 1 of 2
Your configuration
- Unitbar
- Pressure typegauge
- Measuring range0 ... 6 bar gauge
- Process connectioncopper-plated soldering tube connection
- Output signal4 ... 20 mA, 2-wire
- Power supply7 ... 30 V DC
- Electrical connection—
- Cable length—
- Version for specific medianone
- ApprovalscULus
AI suggestion by parameters
Finish your configuration
Select every option to submit the request.
Identification
| Model | R-1 |
| Subcategory | Pressure transmitter |
Measuring range
| Pressure ranges | 0…6 bar · 0…10 bar · 0…15 bar · 0…16 bar · 0…20 bar · 0…25 bar · 0…30 bar · 0…100 bar · -1…7 bar · -1…9 bar · -1…10 bar · -1…15 bar · -0.5…7 bar · -1…20 bar · -0.5…10 bar · -30…100 inHg · -30…400 inHg · -30…145 inHg · -30…450 inHg · -30…200 inHg · -30…500 inHg · -30…250 inHg · -30…550 inHg · -30…300 inHg · -30…600 inHg · -30…350 inHg · 0…35 psi · 0…40 psi · 0…45 psi · 0…50 psi · 0…60 psi · 0…100 psi · 0…160 psi · 0…550 psi · 0…600 psi · 0…650 psi · 0…700 psi · 0…750 psi · 0…800 psi · 0…850 psi · 0…1500 psi · 0…2400 psi · -1…25 psi · -1…29 psi · -1…45 psi · 0…35 bar · 0…40 bar · 0…45 bar · 0…50 bar · 0…60 bar · 0…160 bar · -1…25 bar · -1…29 bar · -1…45 bar |
Accuracy
| Accuracy class | 0.5 % BFSL |
| Accuracy standard | IEC 61298-2 |
Process conditions
| Process connection | Stainless steel blowpipeStainless steel blowpipe, copper-platedG ¼ B⅛ NPT¼ NPTR ¼PT ¼7/16-20 UNF-2A 90°7/16-20 UNF-2B Schrader connectionG1/4B1/8NPT1/4NPTR1/4PT1/4 |
| Process temperature | −40…+100 °C |
Electrical characteristics
| Output signal | 4-20mA · 0-10V · 1-5V · 0.5-4.5V · DC 0...10V · DC 1...5V · DC 0.5...4.5V |
| Power supply | DC 7 ... 30 V |
| Electrical connection | Circular connector M12 x 1 |
Materials
| Case material | Stainless steel |
| Wetted parts material | Stainless steel, Stainless steel, copper coating |
Operating environment
| Ambient temperature | −25…+85 °C |
| IP rating | IP67 |
| Weight | 0.1 kg |
Certifications and approvals
| Certifications | CERoHSEACULCRNUkrSEPRO |
Additional details
| Datasheet languages | EN |
Tables from datasheet
Accuracy specifications
| Non-linearity per BFSL per IEC 61298-2 | ≤ ±0.5 %of span |
|---|---|
| Accuracy | → See 'Max. measured error per IEC 61298-2' |
| Max. measured error per IEC 61298-2 | ≤ ±2 %of span |
| Temperature error at -25 ... +85 °C [-13 ... +185 °F] | |
| Mean temperature coefficient of zero point | Typical: ≤ 0.5 %of span/10 K |
| Mean temperature coefficient of span | ≤ ±0.3 %of span/10 K |
| Long-term drift per IEC 61298-2 | ≤ ±0.3 %of span |
| Reference conditions | Per IEC 61298-1 |
| psi | |
|---|---|
| 0 ... 100 | 0 ... 550 |
| 0 ... 150 | 0 ... 600 |
| 0 ... 200 | 0 ... 650 |
| 0 ... 250 | 0 ... 700 |
| 0 ... 300 | 0 ... 750 |
| 0 ... 350 | 0 ... 800 |
| 0 ... 400 | 0 ... 850 |
| 0 ... 450 | 0 ... 1,500 |
| 0 ... 500 | 0 ... 2,400 |
Further details on: measuring range
| Units | ■ bar ■ psi |
|---|---|
| Maximum working pressure | → Corresponds to the upper measuring range value / measuring range full scale value → Any permanent operation above the maximum working pressure is not permissible |
| Overpressure limit | The overpressure limit is based on the measuring range. Depending on the selected pro - cess connection and the seal, restrictions in overpressure limit can result. |
| Vacuum resistance | Yes |
| bar | |
|---|---|
| -1 ...+7 | -1 ...+25 |
| -1 ...+9 | -1 ...+29 |
| -1 ...+10 | -1 ...+45 |
| -1 ...+15 | -0.5 ...+7 |
| -1 ...+20 | -0.5 ...+10 |
View all (16)
psi
| -30 inHg ...+100 | -30 inHg ...+400 |
|---|---|
| -30 inHg ...+145 | -30 inHg ...+450 |
| -30 inHg ...+200 | -30 inHg ...+500 |
| -30 inHg ...+250 | -30 inHg ...+550 |
| -30 inHg ...+300 | -30 inHg ...+600 |
| -30 inHg ...+350 | - |
Process connection
| Standard | Thread size | Max. measuring range | Overpressure limit |
|---|---|---|---|
| EN 837 | G¼B | 160 bar [2,400 psi] | 2 times |
| ANSI/ASME B1.20.1 | ⅛NPT | 160 bar [2,400 psi] | |
| ¼NPT | 160 bar [2,400 psi] | ||
| ISO 7 | R¼ | 160 bar [2,400 psi] | |
| KS | PT¼ | 160 bar [2,400 psi] | |
| SAE J513 compatible | 7/16-20 UNF-2A 90° | 160 bar [2,400 psi] | |
| - | 7/16-20 UNF-2B Schrader connection | 60 bar [850 psi] | 2 times, max. 80 bar |
| - | Stainless steel blowpipe | 50 bar [700 psi] | |
| Stainless steel blowpipe, copper-plated |
Further details on: process connection
| Max. measuring range | → See table 'Process connection' |
|---|---|
| Overpressure limit | → See table 'Process connection' |
| Pressure port diameter | 3.5 mm(not with Schrader connection and blowpipe version) |
| Output signal | ||
|---|---|---|
| Signal type | ||
| Current (2-wire) | 4 ...20mA | |
| Voltage (3-wire) | ■ DC 0 ...10V ■ DC 1 ...5V | |
| Ratiometric (3-wire) | DC 0.5 ...4.5V | |
| Load Ω | ||
| Current (2-wire) | ≤ (auxiliary power - 7 V) / 0.02 A | |
| Voltage (3-wire) | > max. output signal inV / 0.001 A | |
| Ratiometric (3-wire) | > max. output signal inV / 0.001 A | |
| Voltage supply | ||
| Auxiliary power | Output signal 4 ...20mA | DC 7 ...30V |
| Output signal DC 1 ...5V | DC 8 ...30V | |
| Output signal DC 0 ...10V | DC 14 ...30V | |
| Output signal DC 0.5 ...4.5V | DC 4.5 ...5.5V | |
| Current supply | ||
| Current (2-wire) | Signal current, max.25mA | |
| Voltage (3-wire) | 5mA | |
| Ratiometric (3-wire) | 5mA | |
| Overvoltage resistance | Max.DC 36V | |
| Dynamic behaviour | ||
| Settling time per IEC 61298-2 | ≤ 5 ms |
Electrical connection
| Connection type | ■ Circular connector M12 x 1 ■ Metri-Pack series 150 ■ Cable outlet | |
|---|---|---|
| Cable outlet | ||
| Wire cross-section | 3 x 0.14 mm² | |
| Cable diameter | 3.2mm | |
| Cable length | ■ 0.5 m[1.64 ft] ■ 1 m[3.28 ft] ■ 2 m[6.56 ft] ■ 5 m[16.4 ft] | |
| Pin assignment | → See below | |
| Ingress protection (IP code) per IEC 60529 1) | Plug connection | IP67 |
| Cable outlet | IP69K | |
| Short-circuit resistance | S + vs.U - | |
| Reverse polarity protection | U + vs.U - | |
| Insulation voltage | DC 500V |
Circular connector M12 x 1 (4-pin)
| 2-wire | 3-wire | ||
|---|---|---|---|
| U + | 1 | 1 | |
| U - | 3 | 3 | |
| S + | - | 4 |
| Metri-Pack series 150 | 2-wire | 3-wire | |
|---|---|---|---|
| A B | U + | B | B |
| U - | C | A | |
| C | S + | - | C |
Material
| Material (wetted) | |
|---|---|
| Sensor and process connection | Stainless steel |
| Blowpipe | ■ Stainless steel ■ Stainless steel, copper coating |
| Material (in contact with the environment) | |
| Case | Stainless steel |
| Cable | PVC |
| Electrical connection | Highly resistant glass-fibre reinforced plastic (PBT GF30) |
Operating conditions
| Medium temperature limit | -40 ...+100 °C [-40 ...+212 °F] |
|---|---|
| Ambient temperature limit | -25 ...+85 °C [-13 ...+185 °F] |
| Storage temperature limit | -25 ...+85 °C [-13 ...+185 °F] |
| Humidity | 0 ... 93 %relative humidity |
| Operating altitude | ≤ 2,000 m[≤ 6,561 ft] |
| Pollution degree | 2 |
| Overvoltage category | I |
| Service life | 10 million load cycles |
| Free fall per IEC 60068-2-31 | |
| Multiple packaging | 0.5 m[1.6 ft] |
| Ingress protection (IP code) per IEC 60529 | → See table 'Electrical connection' |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity | European Union | |
| EMCDirective EN 61326 emission (group 1, class B) and immunity (industrial environments) | ||
| Pressure Equipment Directive | ||
| RoHS directive | ||
| EAC Electromagnetic compatibility | Eurasian Economic Com - munity |
| Logo | Description | Region |
|---|---|---|
| UL Safety (e.g. electr. safety, overpressure, ...) | USA and Canada | |
| UL Component approval | USA and Canada | |
| UkrSEPRO Metrology, measurement technology | Ukraine | |
| CRN Safety (e.g. electr. safety, overpressure, ...) | Canada |
| Logo | Description |
|---|---|
| - | China RoHS directive |
| MTTF | > 100 years |
Industry
Heating / Utilities
Refrigeration plants · Air-conditioning systems
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →All variants · Article table
6 standard articles of family R-1
If you know the code — pick directly. If not — use the configurator in mode “01”.
Stock:
SKUConfigurationPriceStockAction
R-1-A-BG360-WV-AG-M4ZZ-WZUnit: B · Pressure type: BG · Measuring range: BG360+ 7 moreOn requestOn orderRequest →
R-1-A-BG360-WV-AG-R3ZZ-WZUnit: B · Pressure type: BG · Measuring range: BG360+ 7 moreOn requestOn orderRequest →
R-1-A-BG360-WV-AG-FNAZ-WZUnit: B · Pressure type: BG · Measuring range: BG360+ 7 moreOn requestOn orderRequest →
R-1-A-BG360-WV-AG-FNHZ-WZUnit: B · Pressure type: BG · Measuring range: BG360+ 7 moreOn requestOn orderRequest →
R-1-A-BG360-WV-AG-FNBZ-WZUnit: B · Pressure type: BG · Measuring range: BG360+ 7 moreOn requestOn orderRequest →
R-1-A-BG360-WV-AG-FNGZ-WZUnit: B · Pressure type: BG · Measuring range: BG360+ 7 moreOn requestOn orderRequest →
Showing 6 of 6. Price on request — an engineer will quote your configuration.