AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
PXA 1
PXA
On order
WIKA · Pressure measurement · Family Process Mini Series

Miniature pressure switch, flameproof enclosure Ex d

Miniature pressure switch with flameproof enclosure Ex d for safety-critical applications in process industries, featuring SIL 2/3 options, robust stainless steel 316 housing, IP66 rating, and wide pressure ranges up to 1,000 bar.
Range
-1…1000 bar
Accuracy
≤ 1 % of end of setting range (set point repeatability)
Protection
IP66
CERoHSEACNACENACE MR0175 / ISO 15156NACE MR0103 / ISO 17945Ex d I MbATEX: II 1/2 GD, II 2 GDEx UkraineCCCKOSHAII 1/2 GDEx d IIC T6/T4 Ga/GbEx d IIC T85°C/T135°C GbEx d IIC T6/T5 GbEx tb IIIC T85/T135 Db IP66ATEXIECEx
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

These high-quality mechanical pressure switches have been developed especially for safety-critical applications. The great advantage of mechanical pressure switches is that no supply voltage is required for the switching process.

In production, the switches are traced by quality assurance software at every step and subsequently are 100 % tested. Due to its compactness, the model PXA pressure switch can be installed in measurement environments with limited space. The robust switch enclosure from stainless steel 316 can withstand the rough and corrosive operating conditions of the process industry with working ranges of up to 1,000 bar.

Special features

  • Compact and slim design
  • Robust switch enclosure from stainless steel 316, IP66, NEMA 4X
  • Wide selection of setting ranges available, 1 … 2.5 bar to 200 … 1,000 bar
  • Set point repeatability of ≤ 1 % for reliable switching
  • High switching power and large selection of contact variants and electrical connections
Identification
ModelPXA
Product familyProcess Mini Series
SubcategoryMechanical pressure switch
Measuring range
Pressure ranges1…2.5 bar · 2…6 bar · 3…10 bar · 6…25 bar · 14…60 bar · 25…100 bar · 50…160 bar · 70…400 bar · 150…700 bar · 200…1000 bar · -1…1.5 bar · 1.6…6 bar
Accuracy
Accuracy class≤ 1 % of end of setting range (set point repeatability)
Accuracy standardIEC 61298-2:2008
Safety integrity level (SIL)SIL 3-capable (option), per IEC 61508 / IEC 61513
Process conditions
Process connection
¼ NPT, female thread½ NPT, female thread via adapter½ NPT, male thread via adapterG ¼, female thread via adapterG ½ A, male thread via adapterG ¼ A, male thread via adapter1/4 NPT, female thread1/2 NPT, female thread via adapter1/2 NPT, male thread via adapterG1/4, female thread via adapterG1/2 A, male thread via adapterG1/4 A, male thread via adapter
Process temperature−40…+200 °C
Electrical characteristics
Electrical connectionThreaded connection with connection cable (½ NPT male, M20 x 1.5, ½ NPT female, ¾ NPT female), terminal box with 3 x ½ NPT female, IP65
Switching functionAdjustable set point with fixed dead band, switching direction (rising/falling) configurable
Switching contacts1
Materials
Case materialStainless steel 316
Wetted parts materialHastelloy C276, Stainless steel 316L
Sealing materialFPM, NBR, EPDM
Operating environment
Ambient temperature−50…+85 °C
IP ratingIP66
Weight0.6 kg
Certifications and approvals
Certifications
CERoHSEACNACENACE MR0175 / ISO 15156NACE MR0103 / ISO 17945
Explosion protection
Ex d I MbATEX: II 1/2 GD, II 2 GDIECEx: Ex d IIC T6/T4, Ex ta/tb IIIC T85°C/T135°C IP66, Ex d IIC T85°C/T135°C Gb, Ex tb IIIC T85°C/T135°C IP66 DbEACEx UkraineCCCKOSHAII 1/2 GDII 2 GD (version with sensor element 'P')Ex d IIC T6/T4 Ga/GbEx ta/tb IIIC T85°C/T135°C IP66 Da/DbEx d IIC T85°C/T135°C GbEx tb IIIC T85°C/T135°C IP66 Db (version with sensor element 'P')Ex d IIC T6/T5 GbEx tb IIIC T85/T135 Db IP66ATEXIECEx
Additional details
Datasheet languagesEN
Tables from datasheet
Basic information
VersionMiniature pressure switch, flameproof enclosure Ex d
Special design feature■ For oxygen, oil- and grease-free ■ Per NACE 1) MR0175 / ISO 15156, use in H₂S-containing environments in oil and gas production ■ Per NACE 1) MR0103 / ISO 17945, metals resistant to sulphide stress cracking ■ Drying of wetted parts ■ Offshore version ■ Tropical version (suitable for environments with increased air humidity) ■ Version for ammonia applications ■ Geothermal version ■ Assembled as a diaphragm seal system
Contact version■ 1 x SPDT (single pole double throw) ■ 1 x DPDT (double pole double throw) Microswitch, hermetically sealed, with fixed dead band The DPDT function is realised with 2 simultaneously triggering SPDT microswitches. →See table 'Contact version'
Dielectric strengthSafety class I (IEC 61298-2: 2008)
Switch enclosure
DesignTamper-proof due to access cover plate with lead seal option Laser-engraved product label from stainless steel
MaterialStainless steel 316
Contact versionElectrical rating (resistive load)
ACDC
E1 x SPDT, silver, hermetically sealed250 V, 5 A24 V, 5 A
J1 x SPDT, gold-plated, hermetically sealed250 V, 0.5 A24 V, 1 A
L1 x DPDT, silver, hermetically sealed250 V, 5 A24 V, 5 A
M1 x DPDT, gold-plated, hermetically sealed250 V, 0.5 A24 V, 1 A
Sensor elementWetted partsPermissible medium temperature 1)
Sensor elementSealing
M1 = Welded diaphragm element with antagonist springHastelloy C276--40 ...+200 °C
2 = Diaphragm element with antagonist spring and O-ringHastelloy C276O-ring:FPM-30 ...+200 °C
GPiston with antagonist spring and welded diaphragm elementHastelloy C276--40 ...+140 °C
PPiston with antagonist spring 2) 3)Stainless steel 316LO-ring:FPM0 ... 200 °C
O-ring:NBR-10 ...+110 °C
O-ring:EPDM-40 ...+110 °C
Accuracy specifications
Set point repeatability≤ 1 %of end of setting range
Dead band→See table 'Setting range of set point'
View all (11)
Setting range of set pointSensor elementSetting range depending on the switching direction in barWorking rangeProof pressureMax. dead band
fallingStart of setting range 4)End of setting range 4)
in bar -1 ... 1.5M 5)rising -0.7 ... 1.5-0.9 ... 1.2in bar -1 ... 10in bar 40in bar 0.3in bar 0.3
1 ... 2.5 6)M 5)1.3 ... 2.51 ... 2.20 ... 10160.30.3
1.6 ... 6M 5)2.1 ... 61.6 ... 5.80 ... 10160.50.2
2 ... 6M 7)2.5 ... 62 ... 5.80 ... 2073150.50.2
3 ... 10M 7)4.5 ... 103 ... 9.20 ... 2073151.50.8
3 ... 10M 5)4.5 ... 103 ... 9.20 ... 10161.50.8
6 ... 25 6)M 5)8 ... 256 ... 24.20 ... 254020.8
6 ... 25M 7)8 ... 256 ... 24.20 ... 20731520.8
14 ... 60P,G23 ... 6014 ... 490 ... 500750911
25 ... 100P,G40 ... 10025 ... 820 ... 5007501518
50 ... 160P,G65 ... 16050 ... 1420 ... 5007501518
70 ... 400P,G95 ... 40070 ... 3650 ... 5007502535
150 ... 700 8)P230 ... 700150 ... 6000 ... 1,0001,50080100
200 ... 1,000 8)P300 ... 1,000200 ... 8500 ... 1,0001,500100150
Process connection
Standard■ ANSI/ASME B1.20.1 ■ DIN EN ISO 228
Size
ANSI/ASME B1.20.1■ ¼NPT, female thread ■ ½NPT, female thread via adapter ■ ½NPT, male thread via adapter
DIN EN ISO 228■ G¼, female thread via adapter ■ G½A,male thread via adapter ■ G¼A,male thread via adapter
Material (wetted)
Process connectionStainless steel 316L
Other materials on request
Sensor elementDepending on the selected sensor element →See table 'Sensor element'
Electrical connection
Connection type■ Threaded connection with connection cable, ½NPTmale thread ■ Threaded connection with connection cable, M20 x 1.5 via adapter ■ Threaded connection with connection cable, ½NPTfemale thread via adapter ■ Threaded connection with connection cable, ¾NPTfemale thread via adapter ■ Terminal box, 3 x female thread ½NPT, IP65
Wire cross-section0.5 mm² (20 AWG)
Cable length
Threaded connection with connection cable■ 1.5m ■ 3m ■ 5m
Terminal box-
Pin assignmentConnection details are given on the product label of the instrument. Connec- tion terminals and the ground terminal are appropriately marked.
Material
Threaded connection with connection cableThreaded connection: Stainless steel 316 Cable sheath: Silicone
Terminal boxAluminium alloy, copper-free, epoxy resin coated
Operating conditions
Medium temperature rangeDepending on sensor element and sealing →See table 'Sensor element'
Ambient temperature rangeT6/T85°C T a -50 ...+60 °C
T4/T135°C T a -50 ...+85 °C
Ingress protection of the complete instrumentIP66 per EN/IEC 60529 (NEMA 4X)
Weight■ 0.6 kg, with cable outlet and 1.5 mconnection cable ■ 1.1 kg, with terminal box
LogoDescriptionRegion
EAC EMCdirectiveEurasian Economic Community
Low voltage directive
Ex Ukraine Hazardous areas 1)Ukraine
CCC Hazardous areas 1)China
KOSHA Hazardous areas 1)South Korea
Certificates
Certificates■ 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, indication accuracy) ■ 3.1 inspection certificate per EN 10204 (e.g. indication accuracy)
Recommended recalibration interval1 year (dependent on conditions of use)
ModelDescription
910.15Syphons →see data sheet AC 09.06
910.13Overpressure protector →see data sheet AC 09.04
IV10, IV11Needle valve and multiport valve →see data sheet AC 09.22
IV20, IV21Block-and-bleed valve →see data sheet AC 09.19
IVMMonoflange, process and instrument version →see data sheet AC 09.17
BVBall valve, process and instrument version →see data sheet AC 09.28