Bourdon tube pressure gauge with output signal
Description
Wherever the process pressure has to be indicated locally under limited space conditions and, at the same time, a signal transmission to the central control or remote centre is desired, the model PGT23.063 intelliGAUGE ® can be used.
Through the combination of a mechanical measuring system and precise electronic signal processing, the process pressure can be read securely, even if the power supply is lost.
WIKA manufactures and qualifies the pressure gauge in accordance with the standards EN 837-1 and ASME B40.100. This safety version is made up of a non-splintering window, a solid baffle wall between measuring system and dial and a blow-out back. In the event of a failure, the operator is protected at the front side, as media or components can only be ejected via the back of the case.
for further approvals, see page 7
Special features
- No configuration necessary due to “plug-and-play”
- Measuring ranges of up to 0 ... 1,000 bar or 0 ... 15,000 psi
- Easy-to-read analogue indication with nominal size 63
- Safety version with solid baffle wall (Solidfront) designed in compliance with the requirements of EN 837-1 and ASME B40.100
- Patents and property rights, e.g. US 8030990, DE 112007000980, CN 101438333
Build a PGT23.063 for your task
The article number is assembled automatically. If unsure — ask an engineer; we'll match the line's parameters.
- ModelPGT23
- Nominal size063
- Output signal4 ... 20 mA, 2-wire
- Unit of outer Scalebar
- Measuring rangegauge pressure range
- Scale range—
- 2nd Scale or Special Scalewithout
- Process connection—
- Connection locationlower mount
- Liquid Damping (case filling)without filling
- Casesolid front design EN837 "S3"
- Mounting optionwithout
- Electrical connection2 m cable
- Restrictorwithout
- Pressure Gauge StandardInternational (standard Europe)
- Special design featureswithout
- Certificateswithout
- Approvalswithout
- Additional ordering informationWithout
Finish your configuration
Select every option to submit the request.
| Model | PGT23.063 |
| Product family | PGT23 |
| Subcategory | Bourdon tube pressure gauge with electrical output signal |
| Pressure ranges | 0…1000 bar · 0…15000 psi · 0…100 kg/cm2 · 0…100000 kPa · 0…100 MPa · -1…0 bar · -1…6 bar · -100…0 kPa · -100…500 kPa · -30…0 inHg · -30…100 inHg · 0…140 kg/cm2 · 0…160 kg/cm2 · 0…200 kg/cm2 · 0…250 kg/cm2 · 0…315 kg/cm2 · 0…400 kg/cm2 · 0…600 kg/cm2 · 0…700 kg/cm2 · 0…1000 kg/cm2 |
| Accuracy class | 1.6 |
| Accuracy standard | EN 837-1 |
| Process connection | G ¼ B¼ NPTG ⅛ BG ½ BM10 x 1M12 x 1.5R ⅛R ¼½ NPT |
| Process temperature | −40…+100 °C |
| Output signal | 4-20mA |
| Power supply | 12...30 V DC |
| Electrical connection | M8 x 1, 4-pin |
| Case material | Stainless steel 1.4301 (304) |
| Wetted parts material | Stainless steel 1.4404 (316L), Stainless steel 1.4571 (316Ti) |
| Ambient temperature | −20…+80 °C |
| IP rating | IP54 |
| Weight | 0.52 kg |
| Certifications | CEUKCACRNEAC |
| Dial size | 63 mm |
| Datasheet languages | EN |
| Basic information | |
|---|---|
| Standard | ■ EN 837-1 ■ ASME B40.100 |
| For information on the 'Selection, installation, handling and operation of pressure gauges', see technical information IN 00.05. | |
| Further version | ■ Oil- and grease-free ■ For oxygen, oil- and grease-free |
| Nominal size (NS) | Ø63 mm[2 ½"] |
| Connection location | Lower mount |
| Window | ■ Polycarbonate ■ Laminated safety glass |
| Case | |
| Design | Safety level 'S3' per EN 837-1 With solid baffle wall and blow-out back Measuring ranges ≤ 0 ... 16 bar [≤ 0 ... 300 psi] with compensating valve to vent and reseal case |
| Material | Stainless steel 1.4301 (304) |
| Ring | Bayonet ring, stainless steel |
| Mounting | ■ Without ■ Surface mounting lugs on the back, stainless steel ■ Panel mounting flange, polished stainless steel |
| Case filling | ■ Without ■ Silicone oil 1) |
| Movement | Stainless steel |
| Type of measuring element | Bourdon tube, C-type or helical type |
|---|---|
| Material | Stainless steel 1.4404 (316L) |
| Leak tightness | Helium tested, leakage rate: < 1∙10 -6 mbar l/s |
| Accuracy specifications | |
|---|---|
| Accuracy of mechanical display | |
| EN 837-1 | Class 1.6 |
| ASME B40.100 | ±2 %│±1%│±2%ofmeasuring span (grade A) |
| Accuracy of output signal | |
| Accuracy | ±1.6 %of measuring span |
| Linearity error | ≤ 1.6 %of measuring span (terminal method) 1) |
| Influence of auxiliary power | < 0.1 %of FS/10V |
| Influence of load | ≤ 0.1 %of FS |
| Long-term stability | < 0.5 %of FS/a |
| Temperature error | On deviation from the reference conditions at the measuring system: ≤ ±0.8 %per 10 °C [≤ ±0.8 %per 18 °F] of full scale value |
| Reference conditions | |
| Ambient temperature | +20 °C [68 °F] |
| bar | |
|---|---|
| 0.2 ... 1 | 0 ... 40 |
| 0 ... 1 | 0 ... 60 |
| 0 ... 1.6 | 0 ... 70 |
| 0 ... 2 | 0 ... 100 |
| 0 ... 2.5 | 0 ... 140 |
| 0 ... 4 | 0 ... 160 |
| 0 ... 6 | 0 ... 200 |
| 0 ... 7 | 0 ... 250 |
| 0 ... 10 | 0 ... 315 |
| 0 ... 14 | 0 ... 400 |
| 0 ... 16 | 0 ... 600 |
| 0 ... 20 | 0 ... 700 |
| 0 ... 25 | 0 ... 1,000 |
| 0 ... 30 |
View all (20)
| kPa | |
|---|---|
| 0 ... 100 | 0 ... 4,000 |
| 0 ... 160 | 0 ... 6,000 |
| 0 ... 200 | 0 ... 7,000 |
| 0 ... 250 | 0 ... 10,000 |
| 0 ... 300 | 0 ... 14,000 |
| 0 ... 400 | 0 ... 16,000 |
| 0 ... 600 | 0 ... 20,000 |
| 0 ... 700 | 0 ... 25,000 |
| 0 ... 1,000 | 0 ... 31,500 |
| 0 ... 1,400 | 0 ... 40,000 |
| 0 ... 1,600 | 0 ... 60,000 |
| 0 ... 2,500 | 0 ... 70,000 |
| 0 ... 3,000 | 0 ... 100,000 |
| psi | |
|---|---|
| 3 ... 15 | 0 ... 600 |
| 0 ... 15 | 0 ... 800 |
| 0 ... 30 | 0 ... 1,000 |
| 0 ... 60 | 0 ... 1,500 |
| 0 ... 100 | 0 ... 2,000 |
| 0 ... 150 | 0 ... 3,000 |
| 0 ... 160 | 0 ... 4,000 |
| 0 ... 200 | 0 ... 5,000 |
| 0 ... 250 | 0 ... 6,000 |
| 0 ... 300 | 0 ... 7,500 |
| 0 ... 400 | 0 ... 10,000 |
| 0 ... 500 | 0 ... 15,000 |
| kg/cm 2 | |
|---|---|
| 0 ... 1 | 0 ... 40 |
| 0 ... 1.6 | 0 ... 60 |
| 0 ... 2 | 0 ... 70 |
| 0 ... 2.5 | 0 ... 100 |
| 0 ... 4 | 0 ... 140 |
| 0 ... 6 | 0 ... 160 |
| 0 ... 7 | 0 ... 200 |
| 0 ... 10 | 0 ... 250 |
| 0 ... 14 | 0 ... 315 |
| 0 ... 16 | 0 ... 400 |
| 0 ... 20 | 0 ... 600 |
| 0 ... 25 | 0 ... 700 |
| 0 ... 30 | 0 ... 1,000 |
| MPa | |
|---|---|
| 0 ... 0.1 | 0 ... 4 |
| 0 ... 0.16 | 0 ... 6 |
| 0 ... 0.2 | 0 ... 7 |
| 0 ... 0.25 | 0 ... 10 |
| 0 ... 0.4 | 0 ... 14 |
| 0 ... 0.6 | 0 ... 16 |
| 0 ... 0.7 | 0 ... 20 |
| 0 ... 1 | 0 ... 25 |
| 0 ... 1.4 | 0 ... 31.5 |
| 0 ... 1.6 | 0 ... 40 |
| 0 ... 2 | 0 ... 60 |
| 0 ... 2.5 | 0 ... 70 |
| 0 ... 3 | 0 ... 100 |
| bar | |
|---|---|
| -1 ... 0 | -1 ...+6 |
| -1 ... +0.6 | -1 ...+7 |
| -1 ...+1 | -1 ...+9 |
| -1 ... +1.5 | -1 ...+10 |
| -1 ...+2 | -1 ...+15 |
| -1 ...+3 | -1 ...+24 |
| -1 ...+4 | -1 ...+25 |
| -1 ...+5 | -1 ...+30 |
| kPa | |
|---|---|
| -100 ... 0 | -100 ...+500 |
| -100 ...+60 | -100 ...+700 |
| -100 ...+100 | -100 ...+900 |
| -100 ...+150 | -100 ... +1,000 |
| -100 ...+200 | -100 ... +1,500 |
| -100 ...+300 | -100 ... +2,400 |
| -100 ...+400 | -100 ... +3,000 |
| -30 inHg ... 0 | -30 inHg ...+100 |
|---|---|
| -30 inHg ...+15 | -30 inHg ...+160 |
| -30 inHg ...+30 | -30 inHg ...+200 |
| -30 inHg ...+60 | -30 inHg ...+300 |
| Special measuring ranges | Other measuring ranges on request |
|---|---|
| Unit | ■ bar ■ psi ■ kg/cm² ■ kPa ■ MPa |
| Increased overload safety | The possibility of selection depends on the scale range |
| Vacuum resistance | ■ Without ■ Vacuum-resistant to -1 bar [-30 inHg] |
| Dial | |
| Scale colour | Black |
| Material | Aluminium |
| Special scale | ■ Without ■ With temperature scale for refrigerant, e.g. for NH 3 :R 717 |
| Other scales or customer-specific dials, e.g. with red mark, circular arcs or circular sectors, on request | |
| Pointer | |
| Instrument pointer | Aluminium, black |
| Pointer stop pin | ■ Without ■ At zero point |
| -1 ... 0 | -1 ...+5 |
|---|---|
| -1 ... +0.6 | -1 ...+7 |
| -1 ...+1 | -1 ...+9 |
| -1 ... +1.5 | -1 ...+10 |
| -1 ...+2 | -1 ...+15 |
| -1 ...+3 | -1 ...+24 |
| -1 ...+4 | -1 ...+30 |
| -0.1 ... 0 | -0.1 ... +0.5 |
|---|---|
| -0.1 ... +0.06 | -0.1 ... +0.7 |
| -0.1 ... +0.1 | -0.1 ... +0.9 |
| -0.1 ... +0.15 | -0.1 ...+1 |
| -0.1 ... +0.2 | -0.1 ... +1.5 |
| -0.1 ... +0.3 | -0.1 ... +2.4 |
| -0.1 ... +0.4 | -0.1 ...+3 |
| Medium temperature | -40 ...+100 °C [-40 ...+212 °F] |
|---|---|
| Ambient temperature | |
| Window: Polycarbonate | -20 ...+80 °C [-4 ...+140 °F] |
| Window: Laminated safety glass | -20 ...+60 °C [-4 ...+140 °F] |
| Pressure limitation | |
| Steady | 3/4 x full scale value |
| Fluctuating | 2/3 x full scale value |
| Short time | Full scale value |
| Ingress protection per IEC/EN 60529 | |
| Without case filling | IP54 |
| With case filling | IP65 |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity | European Union | |
| EMCdirective | ||
| UKCA | United Kingdom | |
| - | CRN | Canada |
| Logo | Description | Region |
|---|---|---|
| EAC EMCdirective | Eurasian Economic Community | |
| - | MChS Permission for commissioning | Kazakhstan |
| PAC Uzbekistan Metrology, measurement technology | Uzbekistan |
| Logo | Description |
|---|---|
| - | Pressure equipment directive (PED) for maximum allowable pressure PS ≤ 200 bar |
| - | Suitability of wetted materials for drinking water in accordance with the European 4MS initiative |
| Certificates | ■ 2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, indication accuracy) ■ 3.1 inspection certificate for indication accuracy per EN 10204 ■ PCA calibration certificate, traceable and accredited in accordance with ISO/IEC 17025 ■ Calibration certificate by a national accreditation body, traceable and accredited in accordance with ISO/IEC 17025 on request |
|---|---|
| Recommended calibration interval | 1 year (dependent on conditions of use) |
| G | Dimensions in mm[in] | |||||||
|---|---|---|---|---|---|---|---|---|
| h ±1 [0.04] | a | b | D1 | D2 | e | S3 | SW | |
| G ¼ B | 54 [2.13] | 18 [0.17] | 42 [1.65] | 63.5 [2.5] | 62 [2.44] | 12.5 [0.49] | 13 [0.51] | 14 [0.55] |
| ¼ NPT | 54 [2.13] | 18 [0.17] | 42 [1.65] | 63.5 [2.5] | 62 [2.44] | 12.5 [0.49] | 13 [0.51] | 14 [0.55] |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →303 standard articles of family PGT23
If you know the code — pick directly. If not — use the configurator in mode “01”.