WIKA · Pressure measurement · Family O-10
OEM pressure transmitter
Low-cost pressure sensor for universal use in OEM applications with pressure ranges from 6 to 600 bar, compact design, and various output signals and process connections.
Range
0…8000 psi
Output
4 ... 20 mA · DC 0.5 ... 4.5 V
Accuracy
0.5 % BFSL
Protection
IP65
CEEACRoHSULGOSTCRN
Price
On request
Depends on configuration
Description
The O-10 is a low-cost pressure sensor for universal use in OEM applications at pressure ranges from 6 to 600 bar. The O-10 is compact and can be integrated into many machine designs. In terms of precision and robustness, it offers application-optimised performance. Thanks to a wide range of connections, signals and measuring ranges, the pressure sensor can be integrated effortlessly. Customer-specific and private label solutions can also be realised.
Special features
- Always the ideal solution, whether standard or customer-specific
- Long-term stability – Reliable measured values over the complete lifecycle
- Consistent quality and delivery performance
Identification
| Model | O-10 (T) |
| Product family | O-10 |
| Subcategory | OEM pressure sensor |
Measuring range
| Pressure ranges | 0…16 bar · 0…25 bar · 0…40 bar · 0…60 bar · 0…100 bar · 0…160 bar · 0…250 bar · 0…400 bar · 0…600 bar · -1…15 bar · -1…5 bar · -1…9 bar · 0…160 psi · 0…200 psi · 0…250 psi · 0…300 psi · 0…400 psi · 0…500 psi · 0…600 psi · 0…750 psi · 0…800 psi · 0…1000 psi · 0…1500 psi · 0…2000 psi · 0…3000 psi · 0…4000 psi · 0…5000 psi · 0…6000 psi · 0…7500 psi · 0…8000 psi · -30…160 inHg · -30…200 inHg · -30…100 inHg · -30…300 inHg · -30…500 inHg · 0…6 bar · 0…10 bar · -1…24 bar · -1…39 bar · -1…59 bar · 0…100 psi |
Accuracy
| Accuracy class | 0.5 % BFSL |
| Accuracy standard | IEC 61298-2 |
Process conditions
| Process connection | M14 x 1.57/16-20 UNF-2A, O-ring BOSS9/16-18 UNF-2A, O-ring BOSSG ⅛ BG ¼ BG ¼ female threadG ⅜ BG ¼ A⅛ NPT¼ NPT¼ NPT female threadG 1/8 BG 1/4 BG 1/4 female threadG 3/8 BG 1/4 A1/8 NPT1/4 NPT1/4 NPT female thread |
| Process temperature | −30…+100 °C |
Electrical characteristics
| Output signal | 4 ... 20 mA · DC 0.5 ... 4.5 V · DC 0 ... 5 V · DC 1 ... 5 V · DC 0 ... 10 V · DC 0.5 ... 4.5 V (ratiometric) |
| Power supply | DC 8 ... 30 V |
| Electrical connection | Angular connector DIN 175301-803 A |
Materials
| Case material | Stainless steel 316L, PBT GF 30 |
| Wetted parts material | Stainless steel 316L, 13-8 PH |
| Sealing material | NBR, FPM/FKM |
Operating environment
| Ambient temperature | −30…+100 °C |
| IP rating | IP65 |
| Weight | 0.08 kg |
Certifications and approvals
| Certifications | CEEACRoHSULGOSTCRN |
Additional details
| Datasheet languages | EN |
Tables from datasheet
Accuracy specifications
| Non-linearity per BFSL per IEC 61298-2 | ≤ ±0.5 %of span 1) |
|---|---|
| Accuracy | → See 'Max. measured error per IEC 61298-2' |
| Max. measured error per IEC 61298-2 | ≤ ±1.2 %of span 2) |
| Zero point error | ≤ ±0.5 %of span |
| Temperature error at 0 ... 80 °C [32 ... 176 °F] | ≤ ±1.5 %of span |
| Long-term stability per DIN 16086 | ≤ ±0.3 %of span/year |
| Reference conditions | Per IEC 61298-1 |
| psi | |
|---|---|
| 0 ... 100 1) 2) | 0 ... 1,000 |
| 0 ... 160 | 0 ... 1,500 |
| 0 ... 200 | 0 ... 2,000 |
| 0 ... 250 | 0 ... 3,000 |
| 0 ... 300 | 0 ... 4,000 |
| 0 ... 400 | 0 ... 5,000 |
| 0 ... 500 | 0 ... 6,000 |
| 0 ... 600 | 0 ... 7,500 |
| 0 ... 750 | 0 ... 8,000 |
| 0 ... 800 |
Further details on: Measuring range
| Overpressure limit | The overpressure limit refers to the measuring range. Depending on the selected process connection and sealing, restrictions in overpressure limit can result. 2-fold |
|---|---|
| Vacuum resistance | Yes |
Process connection
| Standard | Thread size | Max. measuring range | Overpressure limit | Sealing |
|---|---|---|---|---|
| EN 837 | G⅛B | 400 bar [5,800 psi] | 572 bar [8,290 psi] | - |
| G¼B | 600 bar [8,700 psi] | 1,200 bar [17,400 psi] | ||
| G¼female thread | 600 bar [8,700 psi] | 1,200 bar [17,400 psi] | ||
| G⅜B | 600 bar [8,700 psi] | 1,200 bar [17,400 psi] | ||
| DIN EN ISO 1179-2 (formerly DIN 3852-E) | G¼A | 600 bar [8,700 psi] | 858 bar [12,440 psi] | ■ NBR 1) ■ FPM/FKM 2) |
| DIN EN ISO 9974-2 (formerly DIN 3852-E) | M14 x 1.5 | 600 bar [8,700 psi] | 858 bar [12,440 psi] | |
| ANSI/ASME B1.20.1 | ⅛NPT | 400 bar [5,800 psi] | 572 bar [8,290 psi] | - |
| ¼NPT | 600 bar [8,700 psi] | 1,200 bar [17,400 psi] | ||
| ¼NPTfemale thread | 600 bar [8,700 psi] | 1,200 bar [17,400 psi] | ||
| SAE J514 E | 7/16-20 UNF-2A, O-ring BOSS | 600 bar [8,700 psi] | 858 bar [12,440 psi] | FPM/FKM 2) |
| 9/16-18 UNF-2A, O-ring BOSS | 600 bar [8,700 psi] | 858 bar [12,440 psi] |
View all (20)
Further details on: Process connection
| Max. measuring range | → See above |
|---|---|
| Overpressure limit | → See above |
| Sealing | → See above |
| Pressure port diameter | 3.5mm |
| For thread sizes G¼A,¼NPTand7/16-20 UNF-2A, O-ring BOSS, following pressure port diameters on request: ■ 6mm ■ 0.6mm ■ 0.3mm |
Output signal
| Signal type | |
|---|---|
| Current (2-wire) | 4 ...20mA |
| Voltage (3-wire) | ■ DC 0.5 ...4.5V ■ DC 0 ...5V ■ DC 1 ...5V ■ DC 0 ...10V |
| Ratiometric (3-wire) | DC 0.5 ...4.5V |
| Load in Ω | |
| Current (2-wire) | ≤ (supply voltage - 8 V) / 0.02 A |
| Voltage (3-wire) | > maximum output signal /1mA |
| Ratiometric (3-wire) | > 4.5 kΩ |
Output signal
| Voltage supply 1) | ||
|---|---|---|
| Supply voltage | Output signal 4 ...20mA | DC 8 ...30V |
| Output signal DC 0.5 ...4.5V | DC 8 ...30V | |
| Output signal DC 0 ...5V | DC 8 ...30V | |
| Output signal DC 1 ...5V | DC 8 ...30V | |
| Output signal DC 0 ...10V | DC 14 ...30V | |
| Output signal DC 0.5 ...4.5V (ratiometric) | DC5V±10% | |
| Current supply | Current (2-wire) | Corresponds to the value of the output signal current (4 ... 20 mA), maximum 25mA |
| Voltage (3-wire) | 5mA | |
| Overvoltage protection | DC 36V | |
| Dynamic behaviour | ||
| Settling time per IEC 61298-2 | < 2 ms |
Electrical connection
| Connection type | IP code 1) | Wire cross- section | Cable diameter | Cable lengths | Cable material |
|---|---|---|---|---|---|
| Angular connector DIN 175301-803 A | IP65 | - | - | - | - |
| Angular connector DIN 175301-803 C | IP65 | - | - | - | - |
| Circular connector M12 x 1 (4-pin) | IP67 | - | - | - | - |
| Delphi connector Metri-Pack series 150 (3-pin) 2) | IP67 | - | - | - | - |
| Cable outlet | |||||
| Unshielded 3) | IP67 | 0.14mm 2 | 3.4mm | ■ 0.5m ■ 1m ■ 2m ■ 5m | PVC |
| Shielded | IP67 | 0.14mm 2 | 4.3mm | ■ 0.5m ■ 1m ■ 2m ■ 5m | PVC |
Angular connector DIN 175301-803 A
| 2-wire | 3-wire | ||
|---|---|---|---|
| U B | 1 | 1 | |
| 0V | 2 | 2 | |
| S+ | - | 3 |
Circular connector M12 x 1
| 2-wire | 3-wire | ||
|---|---|---|---|
| U B | 1 | 1 | |
| 0V | 3 | 3 | |
| S+ | - | 4 |
Cable outlet, unshielded
| 2-wire | 3-wire | ||
|---|---|---|---|
| U B | Brown (BN) | Brown (BN) | |
| 0V | Green (GN) | Green (GN) | |
| S+ | - | White (WH) |
Further details on: Electrical connection
| Connection type | → See above |
|---|---|
| Wire cross-section | → See above |
| Cable diameter | → See above |
| Cable length | → See above |
| Pin assignment | → See below |
| Ingress protection (IP code) per IEC 60529 | → See above |
| Short-circuit resistance | S+ vs.0V |
| Reverse polarity protection | U B vs.0V |
| Insulation voltage | DC 750V |
Material
| Material (wetted) | Stainless steel 316L and 13-8 PH |
|---|---|
| → Sealing materials, see 'Process connection' | |
| Oil- and grease-free versions on request | |
| Material (in contact with the environment) | Stainless steel 316L and PBT GF 30 |
| → Cable material, see 'Electrical connection' |
Angular connector DIN 175301-803 C
| 2-wire | 3-wire | ||
|---|---|---|---|
| U B | 1 | 1 | |
| 0V | 2 | 2 | |
| S+ | - | 3 |
Delphi connector Metri-Pack series 150 (3-pin)
| 2-wire | 3-wire | ||
|---|---|---|---|
| U B | B | B | |
| 0V | A | A | |
| S+ | - | C |
Cable outlet, shielded
| 2-wire | 3-wire | ||
|---|---|---|---|
| U B | Brown (BN) | Brown (BN) | |
| 0V | Blue (BU) | Blue (BU) | |
| S+ | - | Black (BK) |
Operating conditions
| Medium temperature limit | -30 ...+100 °C [-22 ...+212 °F] |
|---|---|
| Ambient temperature limit | -30 ...+100 °C [-22 ...+212 °F] |
| Storage temperature limit | -30 ...+100 °C [-22 ...+212 °F] |
| Vibration resistance per IEC 60068-2-6 | 20 g (20 ... 2,000 Hz, 120 min) |
| Shock resistance per IEC 60068-2-27 | 40 g (6 ms), mechanical shock |
| Free fall per EN 60068-2-31 | 1m |
| Service life | 10 million load cycles |
Packaging and instrument labelling
| Packaging | Multiple packaging (up to 50 pieces possible) |
|---|---|
| Instrument labelling | ■ WIKA product label, lasered ■ Customer-specific product label on request |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity | European Union | |
| EMCdirective EN 61326 emission (group 1, class B) and immunity (industrial application) | ||
| Pressure equipment directive | ||
| RoHS directive | ||
| EAC | Eurasian Economic Community | |
| EMCdirective |
| Logo | Description | Country |
|---|---|---|
| UL Safety (e.g. electr. safety, overpressure, ...) | USA and Canada | |
| GOST Metrology, measurement technology | Russia | |
| KazInMetr Metrology, measurement technology | Kazakhstan | |
| - | MTSCHS Permission for commissioning | Kazakhstan |
| BelGIM Metrology, measurement technology | Belarus | |
| UkrSEPRO Metrology, measurement technology | Ukraine | |
| - | CRN Safety (e.g. electr. safety, overpressure, ...) | Canada |
Industry
Machinery
Hydraulics and pneumatics · Pumps and compressors · Machine building
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →All variants · Article table
1 standard articles of family O-10
If you know the code — pick directly. If not — use the configurator in mode “01”.
Stock:
SKUConfigurationPriceStockAction
Showing 1 of 1. Price on request — an engineer will quote your configuration.