AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
N1301 1
N1301
On order
WIKA · Force measurement · Family N1301

Inclination sensor

Inclination sensor with 0 ... 360° measuring range, IP67, redundant 4-20 mA output, suitable for cranes and aerial platforms.
Output
2 x 4 ... 20 mA (3-wire)
Accuracy
< 0.1 % of FS
Protection
IP67
EMC 61326-1 IEC:2012DIN EN 61000-4CERoHSDIN ISO 7637DIN ISO 11452DIN EN 55025DIN ISO 7637 Part2DIN EN 55025 Part6.3, Part6.4
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The inclination sensor has a measuring range of 0 … 360°. Other measuring ranges can be implemented on request. This sensor is especially well suited to applications in machine building, medical engineering, on mobile and ship cranes or aerial platforms.

In addition, it is characterised by a low sensitivity to humidity WIKA data sheet FO 59.03

Inclination sensor, model N1301

and easy to retrofit. The sensor offers an extraordinarily high accuracy and precision over the entire measuring range. The reading resolution is 0.01°.

Special features

  • Measuring range 0 ... 360°
  • Relative linearity error < 0.1 % of FS over the entire measuring range
  • Good damping behaviour, no influence due to gravity
  • Resistant to seawater, IP67
  • Easy retrofitting
Identification
ModelN1301
SubcategoryInclination sensor
Accuracy
Accuracy class< 0.1 % of FS
Process conditions
Process temperature−40…+80 °C
Electrical characteristics
Output signal2 x 4 ... 20 mA (3-wire)
Materials
Cell materialAluminium
Operating environment
Ambient temperature−40…+80 °C
IP ratingIP67
Certifications and approvals
Certifications
EMC 61326-1 IEC:2012DIN EN 61000-4CERoHSDIN ISO 7637DIN ISO 11452DIN EN 55025DIN ISO 7637 Part2DIN ISO 11452 Part2, Part4, Part5DIN EN 55025 Part6.3, Part6.4
Additional details
Datasheet languagesEN
Tables from datasheet
Model N1301
Measuring range ■ Standard ■ Optional0 …360° other measuring ranges possible
Relative linearity error d lin ■ < 100° ■ > 100°< 0.1° < 0.1 %of FS
Relative reversibility error v< 0.05 %of FS
Resolution< 0.01°
Transverse inclination error ■ ≤ 10° ■ ≤ 45°< 0.05 ° < 0.2 °
Service temperature B T, G-40 …+80 °C
Temperature effect on ■ the characteristic valueTK c ■ the zero signalTK 00.0016 %of FS/K 0.0016 %of FS/K
Electrical connectionCable, MIL, M12 x 1 (others on request)
Output signal (rated characteristic value) C nom2 x 4 ... 20 mA(3-wire)
Voltage supplyDC 9 ...36V
Material of the measuring bodyAluminium, resistant to seawater
Salt spray testingDIN EN 60068-2-52
Ingress protection (per IEC/EN 60529)IP67
EMC61326-1 IEC:2012, DIN EN 61000-4 Part 2, Part 3, Part 4, Part 6, Part 8, Part 9, Part 10; DIN ISO 7637 Part 2, DIN ISO 11452 Part 2, Part 4, Part 5; DIN EN 55025 Part 6.3, Part 6.4
Cable assignment 2 x 4 ... 20 mA, 3-wire
Cable colourSignal
RedUB+
Black0V/S-
WhiteS+ (signal 1)
BlueS+ (signal 2)
MIL, pinout CA3102E14S-2P-B-A232
PinSignal
AUB+
BS+ (channel x)
C0V/S-
DS+ (channelY)
Circular connector M12 x 1, 2 x 4 ... 20 mA, 3-wire, 4-pin
PinColourSignal
1BrownUB+
3Blue0V/S-
4BlackS+ (signal 1)
2WhiteS+ (signal 2)
M12 x 1ShieldShield