WIKA · Force measurement · Family N1301
Inclination sensor
Inclination sensor with 0 ... 360° measuring range, IP67, redundant 4-20 mA output, suitable for cranes and aerial platforms.
Output
2 x 4 ... 20 mA (3-wire)
Accuracy
< 0.1 % of FS
Protection
IP67
EMC 61326-1 IEC:2012DIN EN 61000-4CERoHSDIN ISO 7637DIN ISO 11452DIN EN 55025DIN ISO 7637 Part2DIN EN 55025 Part6.3, Part6.4
Price
On request
Depends on configuration
Description
The inclination sensor has a measuring range of 0 … 360°. Other measuring ranges can be implemented on request. This sensor is especially well suited to applications in machine building, medical engineering, on mobile and ship cranes or aerial platforms.
In addition, it is characterised by a low sensitivity to humidity WIKA data sheet FO 59.03
Inclination sensor, model N1301
and easy to retrofit. The sensor offers an extraordinarily high accuracy and precision over the entire measuring range. The reading resolution is 0.01°.
Special features
- Measuring range 0 ... 360°
- Relative linearity error < 0.1 % of FS over the entire measuring range
- Good damping behaviour, no influence due to gravity
- Resistant to seawater, IP67
- Easy retrofitting
Identification
| Model | N1301 |
| Subcategory | Inclination sensor |
Accuracy
| Accuracy class | < 0.1 % of FS |
Process conditions
| Process temperature | −40…+80 °C |
Electrical characteristics
| Output signal | 2 x 4 ... 20 mA (3-wire) |
Materials
| Cell material | Aluminium |
Operating environment
| Ambient temperature | −40…+80 °C |
| IP rating | IP67 |
Certifications and approvals
| Certifications | EMC 61326-1 IEC:2012DIN EN 61000-4CERoHSDIN ISO 7637DIN ISO 11452DIN EN 55025DIN ISO 7637 Part2DIN ISO 11452 Part2, Part4, Part5DIN EN 55025 Part6.3, Part6.4 |
Additional details
| Datasheet languages | EN |
Tables from datasheet
| Model N1301 | |
|---|---|
| Measuring range ■ Standard ■ Optional | 0 …360° other measuring ranges possible |
| Relative linearity error d lin ■ < 100° ■ > 100° | < 0.1° < 0.1 %of FS |
| Relative reversibility error v | < 0.05 %of FS |
| Resolution | < 0.01° |
| Transverse inclination error ■ ≤ 10° ■ ≤ 45° | < 0.05 ° < 0.2 ° |
| Service temperature B T, G | -40 …+80 °C |
| Temperature effect on ■ the characteristic valueTK c ■ the zero signalTK 0 | 0.0016 %of FS/K 0.0016 %of FS/K |
| Electrical connection | Cable, MIL, M12 x 1 (others on request) |
| Output signal (rated characteristic value) C nom | 2 x 4 ... 20 mA(3-wire) |
| Voltage supply | DC 9 ...36V |
| Material of the measuring body | Aluminium, resistant to seawater |
| Salt spray testing | DIN EN 60068-2-52 |
| Ingress protection (per IEC/EN 60529) | IP67 |
| EMC | 61326-1 IEC:2012, DIN EN 61000-4 Part 2, Part 3, Part 4, Part 6, Part 8, Part 9, Part 10; DIN ISO 7637 Part 2, DIN ISO 11452 Part 2, Part 4, Part 5; DIN EN 55025 Part 6.3, Part 6.4 |
Cable assignment 2 x 4 ... 20 mA, 3-wire
| Cable colour | Signal |
|---|---|
| Red | UB+ |
| Black | 0V/S- |
| White | S+ (signal 1) |
| Blue | S+ (signal 2) |
MIL, pinout CA3102E14S-2P-B-A232
| Pin | Signal |
|---|---|
| A | UB+ |
| B | S+ (channel x) |
| C | 0V/S- |
| D | S+ (channelY) |
Circular connector M12 x 1, 2 x 4 ... 20 mA, 3-wire, 4-pin
| Pin | Colour | Signal |
|---|---|---|
| 1 | Brown | UB+ |
| 3 | Blue | 0V/S- |
| 4 | Black | S+ (signal 1) |
| 2 | White | S+ (signal 2) |
| M12 x 1 | Shield | Shield |