Reed level transmitter for connection to WIKA radio unit
Description
The model FLRU level transmitter with reed-chain technology in combination with the WIKA model NETRIS ® 3 radio unit is used wherever web-based remote monitoring of level measurement in liquid media is desired. Condition-based and preventive maintenance through centralised big data analysis is thus possible.
Level transmitters of this model series work on the float principle with magnetic transmission and are used wherever centralised, web-based remote monitoring is required. The float's magnetic system in the guide tube actuates a resistance measuring chain that corresponds to a 3-wire
for further approvals, see page 5
Special features
- IIoT-capable measuring instrument in combination with WIKA radio unit, model NETRIS ® 3
- Process- and procedure-specific solutions possible
- Process temperature:T = -80 ... +200 °C [-112 ... +842 °F]
- Operating pressure: P = vacuum to 80 bar [1,160 psi]
- Limit density: ρ ≥ 400 kg/m 3
- Wide variety of different process connections and materials
- Intrinsically safe version Ex i
| Model | FLRU |
| Subcategory | reed-chain |
| Level ranges | 0.5…6 m · 0…0.5 m · 0…1.5 m · 0…3.5 m · 0…6 m |
| Process connection | G 1 1/2, male threadG 2, male threadDN 50 ... DN 200, PN 6 ... PN 1002" ... 8", Class 150 ... Class 600DIN EN ISO 228-1 G 1 1/2 male threadDIN EN ISO 228-1 G 2 male threadEN 1092-1 DN 50 ... DN 200, PN 6 ... PN 100ASME B16.5 2" ... 8", Class 150 ... Class 600DIN EN ISO 228-1 G1½ male thread |
| Process temperature | −80…+200 °C |
| Max process pressure | 80 bar |
| Measurement technology | float |
| Output signal | Unified WIKA Interface (UWI) · 3-wire potentiometer circuit |
| Electrical connection | M12 x 1 circular connector (4-pin), B-coded |
| Wetted parts material | Stainless steel 1.4571 (316Ti), Stainless steel 1.4401 (316L), Stainless steel 1.4404 (316L), Stainless steel 1.4435 (316L), Buna, Titanium |
| Ambient temperature | −40…+105 °C |
| IP rating | IP66/IP68 |
| Certifications | RoHSATEXIECExCE |
| Explosion protection | II 1D Ex ia IIIC T* DaII 2D Ex ia IIIC T* DbII 1G Ex ia IIC T1 - T6 GaII 1/2G Ex ia IIC T1 - T6 Ga/GbII 2G Ex ia IIC T1 - T6 GbII 1/2D Ex ia IIIC T* Da/DbII 1/2D Ex ia IIICT Da/Db |
| Datasheet languages | EN |
| Process temperature range | ■ -40 ...+120 °C [-40 ...+248 °F] ■ -40 ...+200 °C [-40 ...+392 °F] (high-temperature version) | |
|---|---|---|
| Ambient and storage temperature range | -40 ...+105 °C [-40 ...+221 °F] | |
| Version with FKM O-ring -20 ...+105 °C [-4 ...+221 °F] | ||
| Climate class per IEC 60654-1 | Cx (-40 ...+105 °C [-40 ...+221 °F], 5 ... 95 %r.h.) | |
| Version with FKM O-ring: -20 ...+105 °C [-4 ...+221 °F] | ||
| Maximum permissible humidity, condensation | 100 %r.h., condensation permissible | |
| Maximum operating pressure | 80 bar [1,160 psi] | |
| Limit density | ρ ≥ 400 kg/m 3 | |
| Salt mist | IEC 60068-2-11 | |
| Vibration resistance | EN IEC 60721-3-2 | Cl.2M4 |
| EN IEC 60068-2-6 | 10 ... 55 Hz; 20 m/s 2 10 frequency cycles per axis | |
| Shock resistance per IEC 60068-2-27 | ■ 50g ■ 6 ms ■ 3 axes ■ 3 directions ■ 3 times in each direction | |
| Ingress protection per EN IEC 60529 1) | ■ IP66 ■ IP68 | |
| Mounting position | Vertical ± 30° |
| Hazardous gas atmos- phere | Temperature class | Ambient temperature range (T a ) | Process temperature |
|---|---|---|---|
| II 1G Ex ia IIC T1 - T6 Ga II 1/2G Ex ia IIC T1 - T6 Ga/Gb II 2G Ex ia IIC T1 - T6 Gb | T6 | -40 ...+50 °C [-40 ...+122 °F] | -80 ... +71.5 °C [-112 ... +160.7 °F] |
| T5 | -40 ...+75 °C [-40 ...+167 °F] | -80 ... +86.5 °C [-112 ... +187.7 °F] | |
| T4 | -40 ...+105 °C [-40 ...+221 °F] | -80 ... +121.5 °C [-112 ... +250.7 °F] | |
| T3 | -40 ...+105 °C [-40 ...+221 °F] | -80 ... +186.5 °C [-112 ... +367.7 °F] | |
| T2 | -40 ...+105 °C [-40 ...+221 °F] | -80 ...+200 °C [-112 ...+392 °F] | |
| T1 | -40 ...+105 °C [-40 ...+221 °F] | -80 ...+200 °C [-112 ...+392 °F] |
| Hazardous dust/air atmos- pheres | Power P i | Ambient temperature range (T a ) | Process temperature |
|---|---|---|---|
| II 1D Ex ia IIIC T* Da II 1/2D Ex ia IIICT Da/Db II 2D Ex ia IIIC T* Db | 330mW | -40 ...+100 °C [-40 ... 212 °F] | -80 ... 200 °C [-112 ...+392 °F] - 9 K 1) |
| Logo | Description | Region | |
|---|---|---|---|
| EU declaration of conformity | European Union | ||
| RoHS directive ATEX directive Hazardous areas | |||
| IECEx - in combination with ATEX Hazardous areas - Ex i Zone 0 gas Zone 1 mounting to zone 0 gas Zone 1 gas Zone 20 dust Zone 21 mounting to zone 20 dust Zone 21 dust | Ex ia IIC T1...T6 Ga Ex ia IIC T1...T6 Ga/Gb Ex ia IIC T1...T6 Gb Ex ia IIIC T* Da Ex ia IIIC T* Da/Db Ex ia IIIC T* Db | International |