AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
GCS-1 1
GCS-1
On order
WIKA · Pressure measurement · Family GCS

Gas cylinder scale

Gas cylinder scale for level measurement of liquid gases in gas cabinets and gas distribution systems, chemical delivery systems, and industrial weight measurement with high overload limit and IP65 protection.
Output
4-20mA · 0-5V
Accuracy
0.1 % FS
Protection
IP65
RoHSChina RoHSEMCEU declaration of conformityCEII 3G Ex nA IIC T4/T5 Gc XEx nA IIC T4/T5 Gc
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The model GCS-1 gas cylinder scale has been designed for indoor and outdoor use in gas cabinets or gas containers.

Due to its high ingress protection of IP65, there is no concern with using the gas cylinder scale for gas cylinders with heavy condensation.

The robust and compact design features high accuracy and temperature stability, meeting the requirements of the semiconductor industry.

The gas cylinder scale meets the highest overload and EMC requirements in order to ensure safe, error-free and accurate operation.

Gas cylinder scale model GCS-1

Special features

  • High overload protection up to 400 %
  • 0.1 % FS Accuracy
  • Meets the highest EMC requirements
  • Measuring ranges 0 ... 27.22 kg to 0 ... 136.08 kg [0 ... 60 lbs to 0 ... 300 lbs]
  • High ingress protection, IP65, for outdoor use and processes with high condensation
Identification
ModelGCS-1
Product familyGCS
SubcategoryGas cylinder scale
Accuracy
Accuracy class0.1 % FS
Accuracy standardIEC 61298-2
Process conditions
Process temperature−20…+60 °C
Electrical characteristics
Output signal4-20mA · 0-5V · 0-10V · DC0...5V · DC0...10V
Power supplyDC 14 ... 30 V
Electrical connectionCable outlet
Materials
Case materialStainless steel
Wetted parts materialAluminium, Stainless steel
Operating environment
Ambient temperature−20…+50 °C
IP ratingIP65
Weight6 kg
Certifications and approvals
Certifications
RoHSChina RoHSEMCEU declaration of conformityCE
Explosion protection
II 3G Ex nA IIC T4/T5 Gc XEx nA IIC T4/T5 Gc
Additional details
Datasheet languagesEN
Tables from datasheet
Accuracy specifications
Non-linearity per BFSL per IEC 61298-2≤ 0.05 %of span
Accuracy→ See 'Max. measured error per IEC 61298-2'
Max. measured error of the analogue signal per IEC 61298-2≤ 0.1 %of span
Adjustability
Zero point±5 %through built-in potentiometer
Span±5 %through built-in potentiometer
Mean temperature coefficient between -20 ... +50 °C [-4 ... +122 °F]
Zero point≤ ±0.1 %of span / 10 K
Span≤ ±0.1 %of span / 10 K
Long-term stability (per month)≤ 0.04 %of span (at reference condition)
Reference conditionsPer IEC 61298-1
kg
0 ... 27.220 ... 45.36
0 ... 136.08
Further details on: Measuring range
Overload limit
Measuring range 0 ... 27.22 kg [0 ... 60 lbs]4 times
Measuring range 0 ... 45.36 kg [0 ... 100 lbs]3 times
Measuring range 0 ... 136.08 kg [0 ... 300 lbs]2.5 times
Output signal
Signal type
Model GCS-1-A (2-wire)4 ...20mA
Model GCS-1-G (4-wire)DC 0 ...5V
Model GCS-1-F (4-wire)DC 0 ...10V
Load in Ω
Model GCS-1-A≤ (supply voltage - 10 V) / 0.02 A
Model GCS-1-G> 5 kΩ
Model GCS-1-F> 10 kΩ
Voltage supply
Supply voltageDC 14 ...30V
Max. output current≤ 35mA
View all (16)
lbs
0 ... 600 ... 100
0 ... 300
Electrical connection
Connection typeCable outlet
Cable length6 m[20 ft]
Short-circuit resistanceS+ vs. U-
Reverse polarity protectionU+ vs. U-
Insulation voltageDC 500V
Pin assignment (2-wire)
U+ / S+Brown (BN)
U- / S-Black (BK)
Pin assignment (4-wire)
U+Red (RD)
S+Orange (OG)
U-Black (BK)
S-Brown (BN)
Material
SensorAluminium
CaseStainless steel
Base plateStainless steel
Operating conditions
Operating temperature range-20 ...+50 °C [-4 ...+122 °F]
Ambient temperature range
T4-20 ...+50 °C [-4 ...+122 °F]
T5-20 ...+40 °C [-4 ...+104 °F]
Storage temperature range-20 ...+60 °C [-4 ...+140 °F]
Free fallResistant to impact of 90 kg from a height of 10 cm
Ingress protection (IP code) per IEC 60529, industrial qualityIP65
LogoDescriptionCountry
EU declaration of conformityEuropean Union
LogoDescriptionCountry
EU declaration of conformity ATEX directiveEuropean Union
- Ex n Zone 2 gas [II 3G Ex nA IIC T4/T5 Gc X] IECExInternational
LogoDescription
-China RoHS directive
Safety-related characteristic values (Ex)
Ex markingWithout Ex approval
(ATEX) II 3G Ex nA IIC T4/T5 Gc X (IECEx) BVS 16.0001X Ex nA IIC T4/T5 Gc
Safety-related maximum values 1)
Supply voltageModel GCS-1-A (4 ... 20 mA)DC 14 ...24V
Model GCS-1-G (DC 0 ... 5 V)DC 14 ...24V
Model GCS-1-F (DC 0 ... 10 V)DC 14 ...24V
Power limitation P iModel GCS-1-A (4 ... 20 mA)1W
Model GCS-1-G (DC 0 ... 5 V)1W
Model GCS-1-F (DC 0 ... 10 V)1W
DesignationOrder number
Without Ex approval
Measuring range 0 ... 27.22 kg [0 ... 60 lbs]Model GCS-1-A (4 ... 20 mA)14196214
Model GCS-1-G (DC 0 ... 5 V)14196221
Model GCS-1-F (DC 0 ... 10 V)14196228
Measuring range 0 ... 45.36 kg [0 ... 100 lbs]Model GCS-1-A (4 ... 20 mA)14196215
Model GCS-1-G (DC 0 ... 5 V)14196223
Model GCS-1-F (DC 0 ... 10 V)14196229
Measuring range 0 ... 136.08 kg [0 ... 300 lbs]Model GCS-1-A (4 ... 20 mA)14196216
Model GCS-1-G (DC 0 ... 5 V)14196224
Model GCS-1-F (DC 0 ... 10 V)14196230
IECEx Ex nA IIC T4/T5 Gc ATEX II 3G Ex nA IIC T4/T5 Gc X
Measuring range 0 ... 27.22 kg [0 ... 60 lbs]Model GCS-1-A (4 ... 20 mA)14196208
Model GCS-1-G (DC 0 ... 5 V)14196217
Model GCS-1-F (DC 0 ... 10 V)14196225
Measuring range 0 ... 45.36 kg [0 ... 100 lbs]Model GCS-1-A (4 ... 20 mA)14196210
Model GCS-1-G (DC 0 ... 5 V)14196218
Model GCS-1-F (DC 0 ... 10 V)14196226
Measuring range 0 ... 136.08 kg [0 ... 300 lbs]Model GCS-1-A (4 ... 20 mA)14196213
Model GCS-1-G (DC 0 ... 5 V)14196220
Model GCS-1-F (DC 0 ... 10 V)14196227
DesignationOrder number
Digital indicator DI30 in wall-mount enclosureAC 230V12458741
Digital indicator DI30 panel mountingAC 230V7539422
AC 110V12489825