AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
FLC-2770 1
FLC-2770
On order
WIKA · Flow measurement · Family FLC

Flow meter

Insertion flow meter for liquids with electric conductivity ≥ 5 μs/cm, suitable for pipe diameters up to 2,000 mm, with compact or separated signal converter options.
Protection
IP68
CEEMC directive EN 61326Low voltage directive
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The model FLC-2770 insertion flow meter version is a cost-effective and reliable solution for flow measurement. It is available in different lengths in order that it can be matched to different pipe diameters, thus offering a wide range of applications. Liquids with an electric conductivity of at least 5 μs/cm can be measured.

The measuring instrument must be mounted on an empty pipe at a 90° angle to the flow. The insertion depth is 1/8 of the diameter of the flow tube.

A WIKA signal converter, either attached directly to the instrument or separated from it (e.g. model FLC-608), detects the potential difference between the electrodes, processes the signal to calculate the flow and manages communication with the external control systems.

Model FLC-2770

Special features

  • No interference with flow due to low insertion depth
  • For pipe diameters of up to 2,000 mm
Identification
ModelFLC-2770
Product familyFLC
SubcategoryInsertion version with flange
Measuring range
Pipe diameter2000 mm
Accuracy
Accuracy3 %
Process conditions
Process connection
Flange, UNI 6084, DN 40, PN 40, carbon steelFlange, UNI 2278, DN 40, PN16, SS304
Process temperature−40…+80 °C
Max process pressure25 bar
Measurement technologymagnetic
Materials
Wetted parts materialSS304, Carbon steel, Polyoxymethylene, 316L
Operating environment
Ambient temperature−40…+80 °C
IP ratingIP68
Certifications and approvals
Certifications
CEEMC directive EN 61326Low voltage directive
Additional details
Datasheet languagesEN
Tables from datasheet
Specifications
Available pipe diameters80 ...2,000mm
Operating pressure≤ 25 bar
Medium temperature■ -40 ...+80 °C [-40 ...+176 °F] for separated version ■ -40 ...+60 °C [-40 ...+140 °F] for compact version
Materials
Pipe endSS304
Sensor housingSS304
FlangeCarbon steel, SS304
Junction boxPolyoxymethylene
Electrodes316L
Ingress protection per EN 60529IP68 (continuous immersion to 1.5 m)
Compatible signal converters■ Model FLC-608 ■ Model FLC-406
Electrical connectionCable gland M20 x 1.5, terminal block and sealing resin
VersionMax. diameter of the flow tubeDimension LtotDimension L10
A500199125
B1,000269190
C1,600348265
D2,000414335
LogoDescriptionCountry
EU declaration of conformityEuropean Union
EMCdirective EN 61326 emission (group 1, class B) and immunity (industrial application)
Low voltage directive