Flow meter
Description
The model FLC-1222 flow meter is a cost-saving solution for flow monitoring. The possibility of a 'hot tapping' installation, without having to empty the flow tube, enables the compact measuring instrument to be installed quickly and easily. The instrument can be used as a mobile or as a permanent solution.
The flow meter is available in three sizes and is suitable for use in pipe sizes of DN 50 ... DN 2600. Thus, a wide range of flow volumes and velocities can be measured, even in demanding applications.
Flow meter, model FLC-1222
The robust design, which requires no maintenance, enables a high-precision bi-directional measurement. Internal components are lined to protect them against external influences.
A WIKA signal converter, either attached directly to the instrument or separated from it (e.g. model FLC-608), detects the potential difference between the electrodes, processes the signal to calculate the flow and manages communication with the external control systems.
Special features
- Can be used as a mobile or permanent measuring instrument, thanks to “hot tapping” (drilling of pipelines under pressure)
- Pressure gauge connection available
- Testing of flow meters on-site
- No moving parts and no pressure loss
| Model | FLC-1222 |
| Product family | FLC |
| Subcategory | Insertion, retractable |
| Process connection | 1" GAS1" NPT |
| Process temperature | −40…+80 °C |
| Max process pressure | 20 bar |
| Measurement technology | magnetic |
| Wetted parts material | Stainless steel 304, POM, Stainless steel 316L, Nickel-plated steel, Stainless steel 316L (valve option) |
| Ambient temperature | −40…+80 °C |
| IP rating | IP68 |
| Certifications | CEEMC EN 61326RoHS |
| Explosion protection | ATEX (option for separated version)IECEx (option for separated version) |
| Version | Min. diameter of the flow tube | Max. diameter of the flow tube |
|---|---|---|
| DN [in] | DN [in] | |
| S | 50 [2"] | 600 [24"] |
| M | 200 [8"] | 1,600 [64"] |
| L | 450 [18"] | 2,600 [104"] |
| Specifications | |
|---|---|
| Versions | ■ S (DN 50 ... 600) ■ M(DN 200 ... 1500) ■ L (DN 450 ... 2600) |
| Materials | |
| Case material | Stainless steel 304 |
| Sensor head | POM |
| Electrodes | Stainless steel 316L |
| Valve | ■ Nickel-plated steel (standard) ■ Stainless steel 316L |
| Stopcock | ■ 1" GAS ■ 1" NPT |
| Operating pressure | ≤ 20 bar [290 psi] |
| Medium temperature | -40 °C ...+80 °C [-40 ...+176 °F] |
| Ingress protection per EN 60529 | IP68 (continuous immersion to 1.5 m) |
| Compatible signal converters | ■ Model FLC-608A/B/R ■ Model FLC-406 |
| Electrical connection | Cable gland M20 x 1.5, terminal block and sealing resin |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity | European Union | |
| EMCdirective EN 61326 emission (group 1, class B) and immunity (industrial application) | ||
| ATEX directive (option for separated version) | ||
| IECEx (option for separated version) | International |
Couldn't find the answer in the documentation? An engineer will reply within a business day.