Hydraulic ring force transducer
Description
The model F6154 hydraulic ring force transducer in heavy-duty design enables the measurement and display of forces in harsh environmental conditions. Its measuring ranges from 25 kN to 1,500 kN [5,620 lbf to 337,213 lbf]. Applications for hydraulic force measurement can be found in equipment manufacturing, in geotechnology and specialist foundation engineering, in device and special machine building and also with measurement and control systems.
The connection of the display instrument can, optionally, be made using a capillary or measuring hose. This enables the convenient reading of the measured value. Furthermore, the measuring hose offers the possibility of 'separation without any losses', which enables an exchange of the display instrument without the need for dismounting the force measuring unit.
Hydraulic ring force transducer, model F6154
Hydraulic force measurement makes use of a piston-case combination with different seals as a sensor unit. The force acting is the product of the area and the pressure. For the display of the pressure, either pressure gauges, pressure sensors or pressure measuring instruments with contact devices can be used. The scale of the display instrument can be defined in various units, e.g., in N, kN, kg, t.
Special features
- Measuring ranges 0 ... 25 kN to 0 ... 1,500 kN [5,620 lbf to 337,213 lbf]
- Relative linearity error: ±1.0 ... 1.6 % F nom with analogue pressure gauge ±0.5 % F nom with digital pressure gauge or pressure sensor
- ±1.0 ... 1.6 % F nom with analogue pressure gauge
- ±0.5 % F nom with digital pressure gauge or pressure sensor
- Piston stroke ≤ 0.8 mm [≤ 0.03 in]
- Operates without supply voltage
- 5-year leak-tightness warranty
| Model | F6154 |
| Subcategory | Hydraulic ring force transducer |
| Force ranges | 25…1500 kN · 5620…337213 lbf |
| Accuracy class | ±0.5 % Fnom (with digital pressure gauge or pressure sensor), ±1.0...1.6 % Fnom (with analogue pressure gauge) |
| Process temperature | −25…+90 °C |
| Mounting type | Direct mounting with adapter, Capillary, Measuring hose |
| Cell material | Stainless steel, Plastic |
| Ambient temperature | −25…+90 °C |
| IP rating | IP65 |
| Weight | 20.5 kg |
| Certifications | EACCERoHSEU Declaration of ConformityEMC DirectiveRoHS DirectiveEMV-Directive |
| Overload protection | 130 % |
| Datasheet languages | EN |
| Logo | Description | Country |
|---|---|---|
| EU Declaration of Conformity | European Union | |
| EMCDirective | ||
| RoHS Directive | ||
| EAC (Option) | Eurasian Economic Community | |
| EMV-Directive |
| ØA | ØB | ØC | ØD | ØE | F | G | H | I | J | K | L | ØM |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 225 | 142 | 125 | 200 | 250 | 75 | 5 | 22.5 | 20 | 12.5 | 34 | approx.320 | 63 |
| [8.86] | [5.6] | [4.9] | [7.87] | [9.84] | [2.95] | [0.2] | [0.89] | [0.79] | [0.49] | [1.34] | [12.6] | [2.48] |
| Version | Pressure gauge | Digital pressure gauge | Options | ||
|---|---|---|---|---|---|
| Rated force | System pressure | Model 213.40 | Model DG-10 | Measuring hose DN 2 (max. L) | Capillary (max. L) |
| kN | bar | m | m | ||
| 25 [5,620] | 10 | ■ | - | 1.0 | 2.0 |
| 40 [8,992] | 16 | ■ | - | 1.0 | 2.0 |
| 50 [11,240] | 20 | - | ■ 1) | 1.5 | 2.0 |
| 60 [13,488] | 25 | ■ | - | 1.5 | 2.0 |
| 100 [22,481] | 40 | ■ | - | 1.5 | 2.0 |
| 120 [26,977] | 50 | - | ■ | 2.0 | 2.0 |
| 150 [33,721] | 60 | ■ | - | 2.0 | 2.0 |
| 250 [56,202] | 100 | ■ | ■ | 2.0 | 2.0 |
| 400 [89,924] | 160 | ■ | ■ | 2.0 | |
| 600 [134,885] | 250 | ■ | ■ | 3.2 | Other lengths on |
| 1,000 [224,809] | 400 | ■ | ■ | 3.2 | request |
| 1,500 [359,694] | 600 | ■ | ■ | 3.2 | |
| Other rated loads and versions on request |
Couldn't find the answer in the documentation? An engineer will reply within a business day.