Tension/Compression force transducer with strain gauges
Description
The model F2222 tension/compression force transducer with strain gauges offers high accuracy and is suitable for both static and dynamic force measurement in the direct force flow.
The force introduction is carried out via the central through hole with female thread. It ensures axial and perpendicular force introduction and serves to absorb the tension or compression forces. The force is thus transmitted centrally and evenly into the instrument. This enables precise measurement of the actual tension or compression forces in a wide variety of applications.
The measuring spring is elastically deformed by a tension or compression force introduced in the force direction. The resulting mechanical tensions are measured by the strain gauges, converted into an electrical output signal and output as an mV/V signal.
For further approvals, see page 4
Tension/Compression force transducer, model F2222
With its robust stainless steel design, the model F2222 ensures excellent stability and durability under high loading and is ideally suited for harsh operating conditions in industrial automation, test bench construction as well as production plants.
Due to its low installation height, the instrument is suitable for use in confined mounting situations and can be easily integrated into existing plants.
Special features
- Rated forces from 0 ... 5 lb to 0 ... 500,000 lb [0 ... 22.24 N to 0 ... 2,224 kN]
- For static and dynamic measurement
- Force introduction via central through hole with female thread
- Tension/Compression calibration
- Robust design, easy integration, long-term stability
| Model | F2222 |
| Subcategory | Tension/Compression force transducer |
| Force ranges | 0.022…2224 kN · 5…500000 lb · 2.268…226796 kg · 5…500000 lbf |
| Accuracy class | ≤ ±0.2 % Fnom (≤25 lb), ≤ ±0.1 % Fnom (≥50 lb) |
| Process temperature | −54…+121 °C |
| Mounting type | Tension/Compression |
| Output signal | 2 mV/V (≤25 lb), 3 mV/V (≥50 lb) |
| Cell material | Stainless steel |
| Ambient temperature | −54…+121 °C |
| IP rating | IP66 |
| Weight | 0.454 kg |
| Certifications | RoHSCE |
| Explosion protection | ATEX directive Per EN 60079-0:2012 and EN 60079-11:2012 (Ex ib)IECEx Per IEC 60079-0:2011 (Ed. 6) and IEC 60079-11:2011 (Ed. 6) (Ex ib)UL Component approval Per UL 61010-1CSA C22.2 No. 61010-1EACIECExATEX directive Hazardous areas Per EN 60079-0:2012 and EN 60079-11:2012 (Ex ib)IECEx Hazardous areas Per IEC 60079-0:2011 (Ed.6) and IEC 60079-11:2011 (Ed.6) (Ex ib) |
| Overload protection | 150 % |
| Cable length | 1 m |
| Datasheet languages | EN |
| Standard | In accordance with directive VDI/VDE/DKD 2638 |
|---|---|
| Material of the measuring body | Stainless steel |
| Ingress protection (per DIN IEC/EN 60529) | IP66 |
| Weight | Approx. 1 ... 27 lb [approx. 453.5 ... 12,247 g] depending on rated load/force |
| Type of measuring element | Measuring spring with strain gauges |
|---|---|
| Range of use | Determination of tension/compression forces |
| Input resistance R e | 350Ω |
| Output resistance R a | 350Ω |
| Rated displacement s nom | 0.002 ... 0.01 in [0.05 ... 0.25 mm] |
| Force introduction | Central through hole with female thread |
| Relative linearity error d lin | |
|---|---|
| Rated force ≤ 25 lb [≤ 0.11 kN] | ≤ ±0.2%F nom |
| Rated force ≥ 50 lb [≥ 0.22 kN] | ≤ ±0.1%F nom |
| Relative repeatability error in unchanged mounting position b rg | |
| Rated force ≤ 25 lb [≤ 0.11 kN] | ≤ ±0.10%F nom |
| Rated force ≥ 50 lb [≥ 0.22 kN] | ≤ ±0.03%F nom |
| Relative reversibility error v | |
| Rated force ≤ 25 lb [≤ 0.11 kN] | ≤ ±0.10%F nom |
| Rated force ≥ 50 lb [≥ 0.22 kN] | ≤ ±0.08%F nom |
| Relative creep, 30 min at F nom | ≤ ±0.1%F nom |
| Relative deviation of zero signal d S, 0 | ≤±1%F nom |
| Temperature effect on zero signal TC 0 | ≤ ±0.05 %/ 10 K |
| Temperature effect on characteristic value TC C | ≤ ±0.05 %/ 10 K |
| Reference conditions | |
| Calibration | Tension/Compression force |
| lb | ||
|---|---|---|
| 5 | 200 | 75,000 |
| 10 | 500 | 100,000 |
| 20 | 1,000 | 150,000 |
| 25 | 2,000 | 200,000 |
| 50 | 3,000 | 300,000 |
| 100 | 5,000 | 500,000 |
View all (16)
| kg | ||
|---|---|---|
| 2.268 | 90.72 | 34,019 |
| 4.536 | 226.8 453.6 | 45,359 68,039 |
| 9.072 11.34 | 907.2 | 90,718.5 |
| 22.68 | 1,360.8 | 136,078 |
| 45.36 | 2,268 | |
| 226,796 |
| kN [N] | ||
|---|---|---|
| 0.022 [22.24 N] 0.044 [44.48 N] | 0.889 2.224 | 333.62 444.82 |
| 0.088 [88.96 N] | 4.448 | 667.23 |
| 0.111 [111.21 N] | 8.896 | 889.64 |
| 0.222 [222.41 N] | 13.34 | 1,334 |
| 0.444 | 22.24 | 2,224 |
| Force limit F L | 150%F nom |
|---|---|
| Breaking force F B | > 300%F nom |
| Vibration stress F rb per DIN 50100 | ±70%F nom |
| Rated characteristic value C nom | |
|---|---|
| Rated force ≤ 25 lb [≤ 0.11 kN] | 2 mV/V |
| Rated force ≥ 50 lb [≥ 0.22 kN] | 3 mV/V |
| Voltage supply | DC 2 …12V(max.DC 15 V) |
| Connection type | |
|---|---|
| Rated force ≤ 5,000 lb [22.24 kN] | Circular connector, PTIH-10-6P |
| Rated force > 5,000 lb [22.24 kN] | Circular connector, MS3102E-14S-6P |
| → Customer-specific cable outlet on request | |
| Cable length | 1 m[3.28 ft] |
| Insulation resistance R is | >2GΩ |
| Material of the electrical connection with cable outlet | |
| Rated force ≤ 5,000 lb [22.24 kN] | PVC |
| Rated force > 5,000 lb [22.24 kN] | PUR |
| High-temperature version | PTFE |
| Circular connector, 6-pin | ||
|---|---|---|
| A B C D E F | Exc + Exc - Sig - Sig + | A, B |
| C, D | ||
| E | ||
| F |
| Rated temperature range B T, nom | -65 ...+250 °F [-54 …+121 °C] |
|---|---|
| High-temperature version up to 250 °C [482 °F] | |
| Compensated rated temperature range | 59 ... 159.8 °F [15 ... 71 °C] |
| Operating temperature range B T, G | -65 ...+250 °F [-54 …+121 °C] |
| Reference temperature T ref | 73 °F [23 ° C] |
| Storage temperature range | -65 ...+250 °F [-54 …+121 °C] |
| Humidity | 35 ... 85 %relative humidity |
| Condensation | Non-condensing |
| Operating altitude | ≤ 8,202 ft [2,500 m] above sea level |
| Packaging | Individual packaging |
|---|---|
| Instrument labelling (product label) | → See operating instructions, item number 79106250 |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity | European Union | |
| RoHS directive |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity | European Union | |
| IECEx Hazardous areas Per IEC 60079-0:2011 (Ed. 6) and IEC 60079-11:2011 (Ed. 6) (Ex ib) | International | |
| UL Component approval Per UL 61010-1 and CSA C22.2 No. 61010-1 | USA and Canada | |
| EAC | Eurasian Economic Com - munity |
| Rated force Fnom lb | Dimensions in inch | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| A | B | ØC | ØD | E | F | G | H | M | |
| 5 ... 25 | 0.18 | 6 | 2 | 2.50 | 0.82 | 0.75 | 1.25 | 0.80 | 1/4-28 UNF |
| 50 ... 1,000 | 0.28 | 6 | 2.25 | 3 | 0.82 | 0.75 | 1.25 | 1 | 3/8-24 UNF |
| 2,000 ... 5,000 | 0.34 | 6 | 2.63 | 3.50 | 0.82 | 0.75 | 1.25 | 1 | 1/2-20 UNF |
| 7,500 ... 15,000 | 0.40 | 8 | 4.50 | 5.50 | 1.25 | 1.50 | 2.00 | 1.80 | 1-1 UNS |
| 20,000 ... 50,000 | 0.53 | 8 | 4.88 | 6 | 1.25 | 1.50 | 2 | 1.80 | 1 1/2-12 UNF |
| 75,000 ... 100,000 | 0.66 | 12 | 7.75 | 9 | 1.25 | 1.50 | 2 | 2.50 | 2-12 UN |
| 150,000 ... 200,000 | 0.78 | 12 | 9.50 | 11 | 1.25 | 1.50 | 2 | 3 | 2 1/2-12 UN |
| 300,000 ... 500,000 | 1 | 12 | 11.75 | 14 | 1.25 | 1.50 | 2 | 4.25 | 3 1/2-8 UN |
| Rated force Fnom kN | Dimensions inmm | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| A | B | ØC | ØD | E | F | G | H | M | |
| 0.022 ... 0.111 | 4.57 | 6 | 50.8 | 63.5 | 20.83 | 19.1 | 31.75 | 20.3 | 1/4-28 UNF |
| 0.222 ... 4.448 | 7.11 | 6 | 57.2 | 76.2 | 20.83 | 19.1 | 31.75 | 25.4 | 3/8-24 UNF |
| 8.896 ... 22.24 | 8.64 | 6 | 66.8 | 88.9 | 20.83 | 19.1 | 31.75 | 25.4 | 1/2-20 UNF |
| 33.36 ... 66.72 | 10.2 | 8 | 114 | 139.7 | 31.75 | 38.1 | 50.8 | 45.7 | 1-1 UNS |
| 88.96 ... 222.41 | 13.5 | 8 | 124 | 152.4 | 31.75 | 38.1 | 50.8 | 45.7 | 1 1/2-12 UNF |
| 333.62 ... 444.82 | 16.8 | 12 | 196.85 | 228.6 | 31.75 | 38.1 | 50.8 | 63.5 | 2-12 UN |
| 667.23 ... 889.64 | 19.8 | 12 | 241 | 279.4 | 31.75 | 38.1 | 50.8 | 76.2 | 2 1/2-12 UN |
| 1,334 ... 2,224 | 25.4 | 12 | 298.5 | 355.6 | 31.75 | 38.1 | 50.8 | 108 | 3 1/2-8 UN |
Couldn't find the answer in the documentation? An engineer will reply within a business day.
Ask an engineer →