WIKA · Force measurement · Family F1861
Compression load cell
With bilateral spherical force introduction up to 50 t [110,231 lb]
Range
0…50 t
Output
2.0 ±0.2 mV/V
Accuracy
0.03 % Fnom
Protection
IP67
RoHSEACCE
Price
On request
Depends on configuration
Description
The model F1861 compression load cell with strain gauges is designed for measuring high static compression forces and loads and has been specially designed for use in industrial force and weight measurement, particularly in weighing technology.
Special features
- Rated loads from 0 ... 10 t to 0 ... 50 t [0 ... 22,046 lb to 0 ... 110,231 lb]
- Relative linearity error from 0.03 % F nom
- Self-centring rocker pin with anti-rotation tilting lever pin
- Compact design and long-term stability
- Encapsulation, hermetically sealed and welded
Identification
| Model | F1861 |
| Subcategory | Compression load cell |
Measuring range
| Force ranges | 0…10 t · 0…20 t · 0…30 t · 0…40 t · 0…50 t · 0…22046 lbf · 0…44092 lbf · 0…66138 lbf · 0…88185 lbf · 0…110231 lbf · 0…22046 lb · 0…44092 lb · 0…66138 lb · 0…88185 lb · 0…110231 lb |
Accuracy
| Accuracy class | 0.03 % Fnom |
Process conditions
| Process temperature | −10…+40 °C |
| Mounting type | Compression |
Electrical characteristics
| Output signal | 2.0 ±0.2 mV/V |
Materials
| Cell material | Steel, Stainless steel |
Operating environment
| Ambient temperature | −20…+60 °C |
| IP rating | IP67 |
| Weight | 4.3 kg |
Certifications and approvals
| Certifications | RoHSEACCE |
Additional details
| Overload protection | 150 % |
| Cable length | 15 m |
| Datasheet languages | EN |
Tables from datasheet
Basic information / Version per standard
| Standard | In accordance with VDI/VDE/DKD 2638 |
|---|---|
| Material of the measuring body | Steel |
| Ingress protection (per IEC/EN 60529) | IP67 |
| Weight | 4.3 kg [9.48 lb] |
Measuring element
| Type of measuring element | Measuring spring with strain gauges |
|---|---|
| Range of use | For static force measurement |
| Input resistance R e | 400 ±20Ω |
| Output resistance R a | 352 ±3Ω |
| Force introduction | Compression force applied axially and centrally to the spherical cap (bilaterally ). |
Accuracy specifications
| Relative linearity error d lin | 0.03%F nom |
|---|---|
| Relative repeatability error in unchanged mounting position b rg | 0.03%F nom |
| Relative reversibility error v | 0.03%F nom |
| Relative creep, 30 min at F nom | 0.03%F nom |
| Relative deviation of zero signal d S, 0 | ±2%F nom |
| Temperature effect on zero signal TC 0 | 0.02 %/ 10 K |
| Temperature effect on characteristic value TC C | 0.02 %/ 10 K |
Rated load F nom
| t | lb |
|---|---|
| 10 | 22,046 |
| 20 | 44,092 |
| 30 | 66,138 |
| 40 | 88,185 |
| 50 | 110,231 |
View all (11)
Further details on the measuring range
| Force limit F L | 150%F nom |
|---|---|
| Breaking force F B | 250%F nom |
Output signal
| Rated characteristic value C nom | 2.0 ±0.2 mV/V |
|---|---|
| Voltage supply | DC 5 ...10V (max. 15 V) |
Electrical connection
| Connection type | Cable outlet, shielded, flying leads |
|---|---|
| Cable diameter | Ø5mm[0.197 in] |
| Cable length | 15 m[49.21 ft] |
| Material | PUR (polyurethane) |
Operating conditions
| Rated temperature range B T, nom | -10 …+40 °C [+14 ...+104 °F] |
|---|---|
| Operating temperature range B T, G | -20 …+60 °C [-4 ...+140 °F] |
| Humidity | 35 ... 85 %relative humidity |
| Condensation | Non-condensing |
| Operating altitude | ≤ 2,500 m[8,202 ft] above sea level |
Packaging and instrument labelling
| Packaging | Individual packaging |
|---|---|
| IInstrument labelling (product label) | → See operating instructions 14723453 |
| Logo | Description | Region |
|---|---|---|
| EU declaration of conformity | European Union | |
| RoHS directive | ||
| EAC | Eurasian Economic Com- munity | |
| RoHS directive |
| Logo | Description | Order number |
|---|---|---|
| Mounting kit, model AZK01 (Indicative image) | On request | |
| Analogue cable amplifier, model B1940 Analogue cable amplifier for adapting the output signal of the strain gauge instruments to 4 ... 20 mA, 0 ... 20 mAor 0 ...10V for indicators or to the downstream controller | 83805811 | |
| Junction box, model B6578 For the parallel connection of up to 4 force transducers or load cells | 64418893 | |
| Weighing transmitter, model FE230 An amplifier for sensors with mV/V signal, DIN-rail mounting. | On request | |
| Weighing indicator, model FE430 For the connection of 4- or 6-wire load cells with mV/V output | On request | |
| Hand-held indicator, Typ FE630 A mobile indicator and data logger for instruments with mV/V output | 14785125 |
Industry
Machinery
Industrial weighing technology · Production lines and plants
Couldn't find the answer in the documentation? An engineer will reply within a business day.