Hydraulic compression force transducer

Hydraulic compression force transducer with measuring ranges from 0 ... 6 kN to 0 ... 850 kN, stainless steel construction, IP65 rated, operates without supply voltage.
Range
0…850 kN
Accuracy
±1.6 % Fnom (analogue)
Protection
IP65
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The hydraulic compression force transducer model F1145 is available with a nominal size NS 141. Measurement of rated forces from 6 up to 850 kN is possible. The robust mechanical design enables use in harsh operating conditions. Applications for this hydraulic force measurement can be found in equipment manufacturing, in device and special machine building and also with measuring and control systems.

Hydraulic force transducers operate on the principle that the force acting on the piston is converted into a hydraulic pressure - in proportion to the piston surface area. Via the connected measuring instrument, which can be either analogue or digital, the measured value is output. The scale of the connected pressure gauge can be defined in various units, e.g., in N, kN, kg, or even t.

Hydraulic compression force transducer, model F1145

Special features

  • Measuring ranges 0 ... 6 kN to 0 ... 850 kN
  • Relative linearity error ±1.0 ... 1.6 % with analogue pressure gauge, ±0.5 % with digital pressure gauge or pressure sensor (For rated forces below 500 N, the relative linearity error is ±1.6 % F nom for all connected measuring instruments.)
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)
Identification
ModelF1145
SubcategoryHydraulic compression force transducer
Measuring range
Force ranges0…6 kN · 0…850 kN
Accuracy
Accuracy class±1.6 % Fnom (analogue), ±0.5 % Fnom (digital)
Process conditions
Process temperature−25…+50 °C
Mounting typeDirect, Adapter, capillary, measuring hose
Materials
Cell materialStainless steel
Operating environment
Ambient temperature−25…+50 °C
IP ratingIP65
Weight5.6 kg
Additional details
Overload protection100 %
Datasheet languagesEN
Tables from datasheet
Model F1145
Rated force F nom0 ... 6 kN to 0 ... 850 kN
Nominal sizeNS 141
Display ■ Standard ■ OptionPressure gauge 213.40 (NS 63) Digital pressure gauge DG-10 Pressure gauge PSG23.160 (NS 100), optionally with contacts Pressure sensor (on request)
Relative linearity error d lin ■ Standard ■ Option≤ ±1.6%F nom (analogue display) 1) ≤ ±0.5%F nom (pressure sensor/digital pressure gauge) 1)
Limit force F L100%F nom
Breaking force F B> 130%F nom
Rated displacement s nom< 0.5mm
Rated temperature range B T, nom-25 …+50 °C
Ingress protection (per EN/IEC 60529)IP65
CaseStainless steel
PistonStainless steel
Mounting type ■ Standard ■ OptionDirect Adapter, capillary, measuring hose for &#x27;separation without any losses&#x27;
Fill fluidGlycerine 70 %, water30%
Assembly aidThreaded holes on the bottom of the case
OptionsSpacer disc
Weight in kg ■ with pressure gauge 213.40 (NS 63) ■ with digital pressure gauge DG-105.6 5.8
VersionDisplayOptions
Rated forceSystem pressure213.40DG-10Measuring hose DN 2 (max. L)Capillary (max. L)
kNbarm
64--1.0
86-0.51.0
1410-1.02.0
2216-1.02.0
2820- 1)1.52.0
3425-1.52.0
6040-1.52.0
7050-2.02.0
8060-2.02.0
1401002.02.0
2201602.04.0
3502503.24.0
450315-3.24.0
5604003.26.0
8506003.26.0
Other rated loads and versions on request