AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
F1112 1
F1112
On order
WIKA · Force measurement · Family F1112

Hydraulic compression force transducer

NS 3 x 16, 3-jaw clamping force test instrument up to 470 kN
Range
0…470 kN
Accuracy
±1.0 ... 1.6 % Fnom (analogue)
Protection
IP65
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The hydraulic force transducer model F1112, version NS 3 x 16, is suited for regular testing of the clamping force in 3-jaw chucks. It thereby ensures optimum use of the clamping jaws.

Hydraulic force measurement is a simple way to capture and display the forces occurring in various applications. The force is measured using the principle of hydraulics: The force acting on a piston leads to a pressure increase that can be visualised on a connected display instrument. The scale of the display instrument can be defined in various units (e.g. N, kN, kg, t).

Special features

  • Measuring ranges 0 ... 2.5 kN to 0 ... 470 kN
  • Relative linearity error ±1.0 ... 1.6 % F nom with analogue pressure gauge, ±0.5 % F nom with digital pressure gauge or pressure sensor (For rated loads below 500 N, the accuracy is ±1.6 % F nom for all connected measuring instruments.)
  • Piston stroke ≤ 0.5 mm, force introduction as total clamping force
  • Operates without supply voltage
  • 5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)
Identification
ModelF1112
SubcategoryHydraulic compression force transducer
Measuring range
Force ranges0…2.5 kN · 0…470 kN · 0…5 kN · 0…7.5 kN · 0…10 kN · 0…12 kN · 0…19 kN · 0…25 kN · 0…30 kN · 0…50 kN · 0…75 kN · 0…120 kN · 0…190 kN · 0…280 kN
Accuracy
Accuracy class±1.0 ... 1.6 % Fnom (analogue), ±0.5 % Fnom (digital)
Process conditions
Process temperature−10…+50 °C
Mounting typeAdapter L=50mm, Capillary, Measuring hose
Materials
Cell materialStainless steel
Operating environment
Ambient temperature−10…+50 °C
IP ratingIP65
Weight4.1 kg
Additional details
Overload protection130 %
Datasheet languagesEN
Tables from datasheet
Model F1112
Rated force F nom0 ... 2.5 kN to 0 ... 470 kN
Nominal sizeNS 3 x 16
Display ■ Standard ■ OptionPressure gauge 232.57 (NS 100) Digital pressure gauge DG-10 Pressure sensor (on request)
Relative linearity error d lin ■ Standard ■ Option≤ ±1.6%F nom (analogue display) 1) ≤ ±0.5%F nom (pressure sensor/digital pressure gauge) 1)
Limit force F L100%F nom
Breaking force F B> 130%F nom
Force introduction ■ Standard ■ OptionTotal clamping force Clamping force per jaw
Rated displacement s nom< 0.5mm
Rated temperature range B T, nom-10 …+50 °C
Ingress protection (per EN/IEC 60529)IP65
CaseStainless steel
PistonStainless steel
Mounting type ■ Standard ■ OptionAdapterL=50mm Capillary Measuring hose for &#x27;separation without any losses&#x27;
Fill fluidGlycerine/water 70 %/30%
Weight in kg ■ with pressure gauge 232.57 (NS 100) ■ with digital pressure gauge DG-104.1 3.9
VersionDisplayOptions
Rated forceSystem pressure232.57DG-10Measuring hose DN 2 [max. L 1) ]Capillary [max. L 1) ]
kNbarm
2.56-0.51.0
510-1.02.0
7.516-1.02.0
1020- 2)1.52.0
1225-1.52.0
1940-1.52.0
2550-2.02.0
3060-2.02.0
501002.02.0
751602.04.0
1202503.24.0
1904003.26.0
2806003.26.0
4701,000--6.0