AI helper
Describe the task — I'll match 3 WIKA models in 30 seconds
F1102 1
F1102
On order
WIKA · Force measurement · Family F1102

Hydraulic compression force transducer

Welding tongs test instrument up to 36 kN
Range
0…100 N
Accuracy
±1.6 % Fnom (analogue)
Protection
IP65
Price
On request
Depends on configuration
Request a quote
+38 (067) 285-77-70·info@avigan.com.uaViberTelegram

Description

The hydraulic force transducer model F1102 serves to easily capture and display forces in applications of limited mounting space. With its plastic piston, the transducer is especially suited to measure compression forces occurring during closing of welding tongs.

Hydraulic force measurement is a simple way to capture and display the forces occurring in various applications. The force measurement is made using the principle of hydraulics: The force acting on a piston leads to a pressure increase which WIKA data sheet FO 52.16

Hydraulic compression force transducer, model F1102

can be visualised on a connected display instrument. The scale of the display instrument can be defined in various units (e.g. N, kN, kg, t).

Special features

  • Measuring ranges 0 ... 100 N to 0 ... 36 kN
  • Relative linearity error ±1.0 ... 1.6% F nom with analogue pressure gauge, ±0.5 % F nom with digital pressure gauge or pressure sensor (For rated forces below 500 N, the relative linearity error is ±1.6% F nom for all connected measuring instruments.)
  • Piston stroke ≤ 0.5 mm
  • Operates without supply voltage
  • 5-year leak-tightness warranty (Use of the force measuring unit as intended is a prerequisite for the extended 5-year warranty.)
Identification
ModelF1102
SubcategoryHydraulic force transducer
Measuring range
Force ranges0…100 N · 0…36 kN
Accuracy
Accuracy class±1.6 % Fnom (analogue), ±0.5 % Fnom (digital)
Process conditions
Process temperature−25…+50 °C
Mounting typeAdapter L = 50 mm
Materials
Cell materialStainless steel, Plastic (Delrin®)
Operating environment
Ambient temperature−25…+50 °C
IP ratingIP65
Weight0.6 kg
Additional details
Overload protection100 %
Datasheet languagesEN
Tables from datasheet
Model F1102
Rated force F nom0 ... 100 N to 0 ... 36 kN
Nominal sizeNS 6
Display ■ Standard ■ OptionPressure gauge 213.40 (NS 63) Digital pressure gauge DG-10 Pressure sensor (on request)
Relative linearity error d lin ■ Standard ■ Option≤ ±1.6%F nom (analogue display) 1) ≤ ±0.5%F nom (pressure sensor/digital pressure gauge) 1)
Limit force F L100%F nom
Breaking force F B> 130%F nom
Rated displacement s nom< 0.5mm
Rated temperature range B T, nom-25 …+50 °C
Ingress protection (per EN/IEC 60529)IP65
CaseStainless steel
PistonPlastic (Delrin ® )
Mounting type ■ Standard ■ OptionAdapterL=50mm Capillary Measuring hose for &#x27;separation without any losses&#x27;
Fill fluidGlycerine/water 70 %/30%
Weight in kg ■ with pressure gauge 213.40 (NS 63) ■ with digital pressure gauge DG-100.6 1
VersionDisplayOptions
Rated forceSystem pressure 213.40DG-10Measuring hose DN2 [max. L 1) ]Capillary [max. L 1) ]
N/kNbarm
100N1.6 ---
1602.5 ---
2504 --1.0
4006 -0.51.0
60010 -1.02.0
1kN16 -1.02.0
1.220 - 2)1.52.0
1.625 -1.52.0
2.540 -1.52.0
3.250 -2.02.0
460 -2.02.0
6100 2.02.0
10160 2.04.0
16250 3.24.0
20315 -3.24.0
25400 3.26.0
36600 3.26.0