Differential pressure switch
Description
These high-quality pressure switches have been developed especially for safety-critical applications. The high quality of the products and manufacturing in accordance with ISO 9001 ensure reliable monitoring of your plant. In production, the switches are traced by quality assurance software at every step and subsequently are 100 % tested.
In order to ensure as flexible operation as possible, the pressure switches are fitted with micro switches, which enable the switching of an electrical load of up to AC 250 V, 20 A directly.
For lower switching power ratings, such as for PLC applications, argon gas-filled micro switches with gold-plated contacts can be selected.
Special features
- No power supply needed for switching of electrical loads
- Robust switch enclosure from stainless steel 316L, IP66, NEMA 4X
- Setting ranges from 0 ... 16 mbar to 0 ... 40 bar with high static and high one-sided pressure up to 160 bar
- Intrinsic safety Ex ia available
- 1 or 2 independent set points, SPDT or DPDT, high switching power up to AC 250 V, 20 A
| Model | DW |
| Subcategory | Differential pressure switch |
| Pressure ranges | 0…0.16 bar · 0…0.25 bar · 0…0.4 bar · 0…0.6 bar · 0…1 bar · 0…2.5 bar · 0…4 bar · 0…6 bar · 0…10 bar · 0…16 bar · 0…25 bar · 0…40 bar · -0.04…0.12 bar · -0.06…0.19 bar · -0.2…0.2 bar · -0.3…0.3 bar · -0.5…0.5 bar · -1.25…1.25 bar · -2…2 bar · -3…3 bar · -5…5 bar · -8…8 bar · -12.5…12.5 bar · 0…16 mbar · 0…25 mbar · 0…40 mbar · 0…60 mbar |
| Accuracy class | ≤ 1 % of span |
| Accuracy standard | IEC 61298-2:2008 |
| Safety integrity level (SIL) | SIL 2 per IEC 61508 |
| Process connection | ¼ NPT female½ NPT maleG ½ A maleG ¼ A male½ NPT femaleG ¼ femaleM20 x 1.5 male |
| Process temperature | −30…+85 °C |
| Electrical connection | ½ NPT female |
| Switching function | SPDT or DPDT |
| Switching contacts | 1 |
| Case material | Stainless steel 316L |
| Wetted parts material | AISI 316, AISI 316L, AISI 304, Monel 400, Inconel 718 |
| Sealing material | NBR |
| Ambient temperature | −30…+85 °C |
| IP rating | IP66 |
| Weight | 6.2 kg |
| Certifications | CERoHSEACCCCKOSHANACEATEXIECExEx-Ukraine |
| Explosion protection | Ex ia I MaEx ia IIC T6/T4 GaEx ia IIIC T85/T135 Da |
| Datasheet languages | EN |
| Contact version | Electrical rating (resistive load) | Suitable for Ex ia option | ||
|---|---|---|---|---|
| AC | DC | |||
| UN | 1 x SPDT, silver | 250 V, 15 A | 24 V, 2 A, 125 V, 0.5 A, 220 V, 0.25 A | No |
| US | 1 x SPDT, silver, hermetically sealed, argon gas filling 2) | 250 V, 15 A | 24 V, 2 A, 220 V, 0.5 A | Yes |
| UO | 1 x SPDT, gold-plated, hermetically sealed, argon gas filling 2) | 125 V, 1 A | 24 V, 0.5 A | Yes |
| UG | 1 x SPDT, gold-plated | 125 V, 1 A | 24 V, 0.5 A | No |
| UR | 1 x SPDT, silver, adjustable dead band | 250 V, 20 A | 24 V, 2 A, 220 V, 0.5 A | Yes 3) |
| DN | 2 x SPDT or 1 x DPDT, silver | 250 V, 15 A | 24 V, 2 A, 125 V, 0.5 A, 220 V, 0.25 A | No |
| DS | 2 x SPDT or 1 x DPDT, silver, hermetically sealed, argon gas filling 2) | 250 V, 15 A | 24 V, 2 A, 220 V, 0.5 A | Yes |
| DO | 2 x SPDT, or 1 x DPDT gold-plated, hermetically sealed, argon gas filling 2) | 125 V, 1 A | 24 V, 0.5 A | Yes |
| DG | 2 x SPDT or 1 x DPDT, gold-plated | 125 V, 1 A | 24 V, 0.5 A | No |
| Voltage U i | DC 30V |
|---|---|
| Current l i | 100mA |
| Power P i | 0.75W |
| Internal capacitance C i | 0 μF |
| Internal inductance L i | 0mH |
| Setting range | Stainless steel version | NACE version 1) | Monel version | |||
|---|---|---|---|---|---|---|
| Diaphragm | Process connection | Diaphragm | Process connection | Diaphragm | Process connection | |
| 16 mbar | AISI 316 | AISI 316L | - | - | - | |
| 25 mbar | ||||||
| 40 mbar | ||||||
| 60 mbar | ||||||
| 160 mbar | Monel ® 400 | AISI 316L | Monel ® 400 | |||
| 250 mbar | ||||||
| 400 mbar | ||||||
| 600 mbar | ||||||
| 1 bar | ||||||
| 2.5 bar | ||||||
| 4 bar | AISI 304 | |||||
| 6 bar | ||||||
| 10 bar | ||||||
| 16 bar | Inconel ® 718 | Inconel ® 718 | - | |||
| 25 bar | ||||||
| 40 bar |
| Δp-cell | Setting range | Fixed dead band for contact version | Adjustable dead band for contact version | Static / One-sided pressure | |
|---|---|---|---|---|---|
| in bar | 1 contact UN, US, UO, UG in mbar | 2 contacts DN, DS, DO, DG in mbar | 1 contact UR in mbar | in bar | |
| L | 0 ... 0.16 | ≤ 6 | ≤ 6 | 25 ... 60 | ≤ 40, ≤ 100 or ≤ 160 |
| 0 ...0.25 | ≤ 8 | ≤ 8 | 30 ... 80 | ||
| - | 0 ... 0.4 | ≤ 20 | ≤ 20 | 45 ... 120 | |
| 0 ... 0.6 | ≤ 25 | ≤ 25 | 80 ... 200 | ||
| 0 ... 1 | ≤ 40 | ≤ 40 | 100 ... 270 | ||
| 0 ... 2.5 | ≤ 70 | ≤ 70 | 260 ... 700 | ||
| 0 ... 4 | ≤ 120 | ≤ 120 | 450 ... 1,150 | ||
| 0 ... 6 | ≤ 180 | ≤ 180 | 600 ... 1,600 | ||
| 0 ... 10 | ≤ 300 | ≤ 300 | 1,100 ... 2,800 | ||
| 0 ... 16 | ≤ 480 | ≤ 480 | 1,600 ... 3,500 | ||
| 0 ... 25 | ≤ 700 | ≤ 700 | 2,500 ... 5,500 | ||
| V | 0 ... 40 | ≤ 1,200 | ≤ 1,200 | on request |
View all (6)
| Δp-cell | Setting range | Fixed dead band for contact version | Adjustable dead band for contact version | Static / One-sided pressure | |
|---|---|---|---|---|---|
| in mbar | 1 contact UN, US, UO, UG in mbar | 2 contacts DN, DS, DO, DG in mbar | 1 contact UR in mbar | in bar | |
| - | 0 ... 16 | ≤ 1.2 | ≤ 1.6 | - | ≤ 10 2) |
| 0 ... 25 | ≤ 1.2 | ≤ 1.6 | 4 ... 10 | ≤ 10 | |
| 0 ... 40 | ≤ 1.6 | ≤ 2.2 | 5 ... 14 | ||
| 0 ... 60 | ≤ 2.5 | ≤ 3.0 | 6 ... 18 |
| Logo | Description | Country |
|---|---|---|
| EU declaration of conformity ■ Pressure equipment directive ■ Low voltage directive ■ RoHS directive ■ ATEX directive 1) (option) IM1 II1GD | European Community | |
| IECEx 1) (option) Ex ia I Ma Ex ia IIC T6/T4 2) Ga Ex ia IIIC T85/T135 2) Da | IECEx member states | |
| EAC (option) Hazardous areas | Eurasian Economic Community | |
| Ex-Ukraine (option) Hazardous areas | Ukraine | |
| CCC (option) Hazardous areas | China | |
| KOSHA (option) Hazardous areas | South Korea |